메뉴 건너뛰기




Volumn 118, Issue 1, 2007, Pages 80-97

Automated protocol for evaluation of electromagnetic component separation (APECS): Application of a framework for evaluating statistical methods of blink extraction from multichannel EEG

Author keywords

BSS; Electroencephalography; ICA; Ocular artifacts

Indexed keywords

ACCURACY; ALGORITHM; ARTICLE; ARTIFACT; AUTOMATION; ELECTROENCEPHALOGRAPHY; ELECTROMAGNETIC FIELD; EVALUATION; EYELID REFLEX; INDEPENDENT COMPONENT ANALYSIS; OUTCOME ASSESSMENT; PRIORITY JOURNAL; QUALITATIVE ANALYSIS; QUANTITATIVE ANALYSIS; STATISTICAL ANALYSIS;

EID: 33845683028     PISSN: 13882457     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.clinph.2006.07.317     Document Type: Article
Times cited : (22)

References (34)
  • 2
    • 1842455280 scopus 로고    scopus 로고
    • Optimization of an independent component analysis approach for artifact identification and removal in magnetoencephalographic signals
    • Barbati G., Porcaro C., Zappasodi F., Rossini P.M., and Tecchio F. Optimization of an independent component analysis approach for artifact identification and removal in magnetoencephalographic signals. Clin Neurophysiol 115 (2003) 1220-1232
    • (2003) Clin Neurophysiol , vol.115 , pp. 1220-1232
    • Barbati, G.1    Porcaro, C.2    Zappasodi, F.3    Rossini, P.M.4    Tecchio, F.5
  • 3
    • 0029411030 scopus 로고
    • An information maximization approach to blind separation and blind deconvolution
    • Bell A., and Sejnowski T. An information maximization approach to blind separation and blind deconvolution. Neural Comput 7 6 (1995) 1004-1034
    • (1995) Neural Comput , vol.7 , Issue.6 , pp. 1004-1034
    • Bell, A.1    Sejnowski, T.2
  • 5
    • 0026320416 scopus 로고
    • Dipole modeling of eye activity and its application to the removal of eye artifacts from the EEG and MEG
    • Berg P., and Scherg M. Dipole modeling of eye activity and its application to the removal of eye artifacts from the EEG and MEG. Clin Phys Physiol Measur 12 Suppl. A (1991) 49-54
    • (1991) Clin Phys Physiol Measur , vol.12 , Issue.SUPPL. A , pp. 49-54
    • Berg, P.1    Scherg, M.2
  • 7
    • 0032187518 scopus 로고    scopus 로고
    • Blind signal separation: statistical principles
    • Cardoso J.-F. Blind signal separation: statistical principles. Proc IEEE 9 (1998) 2009-2025
    • (1998) Proc IEEE , Issue.9 , pp. 2009-2025
    • Cardoso, J.-F.1
  • 8
    • 1242314732 scopus 로고    scopus 로고
    • Principal component analysis for reduction of ocular artifacts in event-related potentials of normal and dyslexic children
    • Casarotto S., Bianchi A.M., Cerutti S., and Chiarenza G.A. Principal component analysis for reduction of ocular artifacts in event-related potentials of normal and dyslexic children. Clin Neurophysiol 115 3 (2004) 609-619
    • (2004) Clin Neurophysiol , vol.115 , Issue.3 , pp. 609-619
    • Casarotto, S.1    Bianchi, A.M.2    Cerutti, S.3    Chiarenza, G.A.4
  • 10
    • 1242283941 scopus 로고    scopus 로고
    • EEGLAB: an open source toolbox for analysis of single-trial EEG dynamics including ICA
    • Delorme A., and Makeig S. EEGLAB: an open source toolbox for analysis of single-trial EEG dynamics including ICA. J Neurosci Methods 134 (2004) 9-21
    • (2004) J Neurosci Methods , vol.134 , pp. 9-21
    • Delorme, A.1    Makeig, S.2
  • 11
    • 0034212891 scopus 로고    scopus 로고
    • Differentiating the N3 and N4 electrophysiological semantic incongruity effects
    • Dien J., Frishkoff G., and Tucker D. Differentiating the N3 and N4 electrophysiological semantic incongruity effects. Brain and Cognition 43 (2000) 148-152
    • (2000) Brain and Cognition , vol.43 , pp. 148-152
    • Dien, J.1    Frishkoff, G.2    Tucker, D.3
  • 12
    • 33845616302 scopus 로고    scopus 로고
    • Dien J. ICA Toolbox [Computer software]. University of Kansas, Attention & Emotion Laboratory; 2004.
  • 13
    • 0031693283 scopus 로고    scopus 로고
    • Addressing misallocation of variance in principal components analysis of event-related potentials
    • Dien J. Addressing misallocation of variance in principal components analysis of event-related potentials. Brain Topography 11 1 (1998) 43-55
    • (1998) Brain Topography , vol.11 , Issue.1 , pp. 43-55
    • Dien, J.1
  • 14
    • 33845610076 scopus 로고    scopus 로고
    • Frishkoff GA, Dien J, Tucker DM, Westbury C. Effects of orthographic set size on event-related brain potentials during lexical access: parametric analysis of words and pseudowords in a lexical decision task. In: Poster presented at the Cognitive Neuroscience Meeting 2003, New York City; 2003.
  • 15
    • 33845639613 scopus 로고    scopus 로고
    • Glass K, Frishkoff G, Frank R. A framework for evaluating ICA methods of artifact removal from multichannel EEG. In ICA 2004 - 5th International Conference on ICA and BSS, Grenada, Spain; 2004.
  • 17
    • 33845655547 scopus 로고    scopus 로고
    • Harmeling S, Mieinecke F et al. Analyzing ICA components by injecting noise. In: 4th International Conference on Independent Component Analysis and Blind Signal Separation, Nara, Japan; 2003.
  • 18
    • 0032629347 scopus 로고    scopus 로고
    • Fast and robust fixed-point algorithms for independent component analysis
    • Hyvarinen A. Fast and robust fixed-point algorithms for independent component analysis. IEEE Trans Neural Networks 10 3 (1999) 626-634
    • (1999) IEEE Trans Neural Networks , vol.10 , Issue.3 , pp. 626-634
    • Hyvarinen, A.1
  • 19
    • 0041435860 scopus 로고    scopus 로고
    • Independent component analysis: algorithms and applications
    • Hyvarinen A., and Oja E. Independent component analysis: algorithms and applications. Neural Networks 12 3 (1999) 429-439
    • (1999) Neural Networks , vol.12 , Issue.3 , pp. 429-439
    • Hyvarinen, A.1    Oja, E.2
  • 21
    • 33845666600 scopus 로고    scopus 로고
    • Hyvarinen A, Oja E. FastICA [Computer software]. Helsinki University of Technology, Laboratory of Computer & Information Science, Neural Networks Research Centre; 2004.
  • 22
    • 0036103009 scopus 로고    scopus 로고
    • Artifact correction of the ongoing EEG using spatial filters based on artifact and brain signal topographies
    • Ille N., Berg P., and Scherg M. Artifact correction of the ongoing EEG using spatial filters based on artifact and brain signal topographies. J Clin Neurophysiol 19 2 (2002) 113-124
    • (2002) J Clin Neurophysiol , vol.19 , Issue.2 , pp. 113-124
    • Ille, N.1    Berg, P.2    Scherg, M.3
  • 23
    • 0141960372 scopus 로고    scopus 로고
    • Independent component analysis as a tool to eliminate artifacts in EEG: a quantitative study
    • Iriarte J., Urrestarazu E., Valencia M., Alegre M., Malanda A., Viteri C., et al. Independent component analysis as a tool to eliminate artifacts in EEG: a quantitative study. J Clin Neurophysiol 20 4 (2003) 249-257
    • (2003) J Clin Neurophysiol , vol.20 , Issue.4 , pp. 249-257
    • Iriarte, J.1    Urrestarazu, E.2    Valencia, M.3    Alegre, M.4    Malanda, A.5    Viteri, C.6
  • 24
    • 1942472547 scopus 로고    scopus 로고
    • Automatic removal of eye movement and blink artifacts from EEG data using blind component separation
    • Joyce C.A., Gorodnitsky I.F., and Kutas M. Automatic removal of eye movement and blink artifacts from EEG data using blind component separation. Psychophysiology 41 2 (2004) 313-325
    • (2004) Psychophysiology , vol.41 , Issue.2 , pp. 313-325
    • Joyce, C.A.1    Gorodnitsky, I.F.2    Kutas, M.3
  • 25
    • 0034108247 scopus 로고    scopus 로고
    • Removing electroencephalographic artifacts by blind source separation
    • Jung T., and Makeig S. Removing electroencephalographic artifacts by blind source separation. Psychophysiology 37 (2000) 163-178
    • (2000) Psychophysiology , vol.37 , pp. 163-178
    • Jung, T.1    Makeig, S.2
  • 26
    • 0034307938 scopus 로고    scopus 로고
    • Removal of eye activity artifacts from visual event-related potentials in normal and clinical subjects
    • Jung T.P., Makeig S., Westerfield M., Townsend J., Courchesne E., and Sejnowski T.J. Removal of eye activity artifacts from visual event-related potentials in normal and clinical subjects. Clin Neurophysiol 111 10 (2000) 1745-1758
    • (2000) Clin Neurophysiol , vol.111 , Issue.10 , pp. 1745-1758
    • Jung, T.P.1    Makeig, S.2    Westerfield, M.3    Townsend, J.4    Courchesne, E.5    Sejnowski, T.J.6
  • 27
    • 33847155118 scopus 로고    scopus 로고
    • Keith D, Hoge C, Frank R, Malony A. Parallel ica methods for eeg neuroimaging In: IEEE International Parallel & Distributed Processing Symposium, Rhodes, Greece, 2006.
  • 28
    • 0033556834 scopus 로고    scopus 로고
    • Independent Component Analysis using an extended infomax algorithm for mixed subgaussian and supergaussian sources
    • Lee T.W., Girolami M., and Sejnowski T.J. Independent Component Analysis using an extended infomax algorithm for mixed subgaussian and supergaussian sources. Neural Comput 11 2 (1999) 417-441
    • (1999) Neural Comput , vol.11 , Issue.2 , pp. 417-441
    • Lee, T.W.1    Girolami, M.2    Sejnowski, T.J.3
  • 30
    • 0027214741 scopus 로고
    • Spatial sampling of head electrical fields: the Geodesic Sensor Net
    • Tucker D.M. Spatial sampling of head electrical fields: the Geodesic Sensor Net. Electroencephalogr Clin Neurophysiol 87 (1993) 154-163
    • (1993) Electroencephalogr Clin Neurophysiol , vol.87 , pp. 154-163
    • Tucker, D.M.1
  • 32
    • 0031239460 scopus 로고    scopus 로고
    • Extraction of ocular artifacts from EEG using independent component analysis
    • Vigario R.N. Extraction of ocular artifacts from EEG using independent component analysis. Electroencephalogr Clin Neurophysiol 103 (1997) 395-404
    • (1997) Electroencephalogr Clin Neurophysiol , vol.103 , pp. 395-404
    • Vigario, R.N.1
  • 33
    • 0036550546 scopus 로고    scopus 로고
    • Blind noise reduction for multisensory signals using ICA and subspace filtering, with application to EEG analysis
    • Vorobyov S., and Cichocki A. Blind noise reduction for multisensory signals using ICA and subspace filtering, with application to EEG analysis. Biol Cybernet 86 (2002) 293-303
    • (2002) Biol Cybernet , vol.86 , pp. 293-303
    • Vorobyov, S.1    Cichocki, A.2
  • 34
    • 2942755691 scopus 로고    scopus 로고
    • Automatic correction of ocular artifacts in the EEG: a comparison of regression-based and component-based methods
    • Wallstrom G.L., Kass R.E., Miller A., Cohn J.F., and Fox N.A. Automatic correction of ocular artifacts in the EEG: a comparison of regression-based and component-based methods. Int J Psychophysiol 53 (2004) 105-119
    • (2004) Int J Psychophysiol , vol.53 , pp. 105-119
    • Wallstrom, G.L.1    Kass, R.E.2    Miller, A.3    Cohn, J.F.4    Fox, N.A.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.