메뉴 건너뛰기




Volumn 2006, Issue , 2006, Pages 2946-2951

Classifying knee pathologies using instantaneous screws of the six degrees-of-freedom knee motion

Author keywords

Knee kinematic; Pathology classification; Screw axis; Support vector machines

Indexed keywords

BIOMECHANICS; BONE; DEGREES OF FREEDOM (MECHANICS); KINEMATICS; LEARNING SYSTEMS; OPTICAL SYSTEMS;

EID: 33845667593     PISSN: 10504729     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/ROBOT.2006.1642149     Document Type: Conference Paper
Times cited : (4)

References (24)
  • 1
    • 0141429902 scopus 로고    scopus 로고
    • Accuracy of physical diagnostic tests for assessing ruptures of the anterior cruciate ligament: A meta-analysis
    • R. J. Scholten, W. Opstelten, C. G. van der Plas, D. Bijl, and W. L. Deville, "Accuracy of physical diagnostic tests for assessing ruptures of the anterior cruciate ligament: a meta-analysis," J. Fam. Pract., vol. 52, no. 9, pp. 689-694, 2003.
    • (2003) J. Fam. Pract. , vol.52 , Issue.9 , pp. 689-694
    • Scholten, R.J.1    Opstelten, W.2    Van Der Plas, C.G.3    Bijl, D.4    Deville, W.L.5
  • 2
    • 0018372025 scopus 로고
    • Methods, difficulties and inaccuracies in the study of human joint kinematics and pathokinematics by the instant axis concept. Example: The knee joint
    • K. Soudan, R. Van Audekercke, and M. Martens, "Methods, difficulties and inaccuracies in the study of human joint kinematics and pathokinematics by the instant axis concept. Example: the knee joint," J. Biomech.,vol. 12, no. 1, pp. 27-33, 1979.
    • (1979) J. Biomech. , vol.12 , Issue.1 , pp. 27-33
    • Soudan, K.1    Van Audekercke, R.2    Martens, M.3
  • 3
    • 0021844595 scopus 로고
    • Finite centroid and helical axis estimation from noisy landmark measurements in the study of human joint kinematics
    • H. J. Woltring, R. Huiskes, A. de Lange, and F. E. Veldpaus, "Finite centroid and helical axis estimation from noisy landmark measurements in the study of human joint kinematics," J. Biomech., vol. 185, pp. 379-389, 1985.
    • (1985) J. Biomech. , vol.185 , pp. 379-389
    • Woltring, H.J.1    Huiskes, R.2    De Lange, A.3    Veldpaus, F.E.4
  • 4
    • 0025687556 scopus 로고
    • Helical axes of passive knee joint motions
    • L. Blankevoort, R. Huiskes, and A. De Lange, "Helical axes of passive knee joint motions," J. Biomech.,vol. 23, no. 12, pp. 1219-1229, 1990.
    • (1990) J. Biomech. , vol.23 , Issue.12 , pp. 1219-1229
    • Blankevoort, L.1    Huiskes, R.2    De Lange, A.3
  • 5
    • 0025859854 scopus 로고
    • A finite helical axis as a landmark for kinematic reference of the knee
    • May
    • R. Hart, C. J. Mote, and H. Skinner, "A finite helical axis as a landmark for kinematic reference of the knee," J. Biomech. Eng., vol. 113, no. 2, pp. 215-222, May 1991.
    • (1991) J. Biomech. Eng. , vol.113 , Issue.2 , pp. 215-222
    • Hart, R.1    Mote, C.J.2    Skinner, H.3
  • 6
    • 0028533238 scopus 로고
    • Three-dimensional knee joint movements during a step-up: Evaluation after anterior cruciate ligament rupture
    • November
    • H. Jonsson and J. Karrholm, "Three-dimensional knee joint movements during a step-up: evaluation after anterior cruciate ligament rupture," J. Orthp. Res., vol. 12, no. 6, pp. 769-779, November 1994.
    • (1994) J. Orthp. Res. , vol.12 , Issue.6 , pp. 769-779
    • Jonsson, H.1    Karrholm, J.2
  • 7
    • 0032101873 scopus 로고    scopus 로고
    • Factors influencing accuracy of screw displacement axis detection with a D.C.-based electromagnetic tracking system
    • M. Bottlang, J. L. Marsh, and T. D. Brown, "Factors influencing accuracy of screw displacement axis detection with a D.C.-based electromagnetic tracking system," J. Biomech. Eng.-T ASME, vol. 120, no. 3, pp. 431-435, 1998.
    • (1998) J. Biomech. Eng.-T ASME , vol.120 , Issue.3 , pp. 431-435
    • Bottlang, M.1    Marsh, J.L.2    Brown, T.D.3
  • 8
    • 0345735672 scopus 로고    scopus 로고
    • Assessment of screw displacement axis accuracy and repeatability for joint kinematic description using an electromagnetic tracking device
    • T. R. Duck, L. M. Ferreira, G. J. W. King, and J. A. Johnson, "Assessment of screw displacement axis accuracy and repeatability for joint kinematic description using an electromagnetic tracking device," J. Biomech., vol. 37, no. 1, pp. 163, 2004.
    • (2004) J. Biomech. , vol.37 , Issue.1 , pp. 163
    • Duck, T.R.1    Ferreira, L.M.2    King, G.J.W.3    Johnson, J.A.4
  • 9
    • 0023225438 scopus 로고
    • Helical motion analysis of the knee-I. Methodology for studying kinematics during locomotion
    • R. Shiavi, et al., "Helical motion analysis of the knee-I. Methodology for studying kinematics during locomotion," J. Biomech., vol. 20, no. 5, pp. 459-469, 1987.
    • (1987) J. Biomech. , vol.20 , Issue.5 , pp. 459-469
    • Shiavi, R.1
  • 11
    • 0032411404 scopus 로고    scopus 로고
    • A point cluster method for in vivo motion analysis: Applied to a study of knee kinematics
    • Dec
    • T. P. Andriacchi, E. J. Alexander, M. K. Toney, C. O. Dyrby, and J. A. Sum, "A point cluster method for in vivo motion analysis: applied to a study of knee kinematics," J. Biomech. Eng., vol. 120, no. 6, pp. 743-749, Dec 1998.
    • (1998) J. Biomech. Eng. , vol.120 , Issue.6 , pp. 743-749
    • Andriacchi, T.P.1    Alexander, E.J.2    Toney, M.K.3    Dyrby, C.O.4    Sum, J.A.5
  • 12
    • 0006829422 scopus 로고    scopus 로고
    • Dynamic evaluation of knee instability during gait in anterior cruciate ligament deficient patients
    • S. S. Hasan, D. E. Hurwitz, C. A. Bush-Joseph, B. B. J. Bach, and T. P. Andriacchi, "Dynamic evaluation of knee instability during gait in anterior cruciate ligament deficient patients," Trans. Orthop. Res. Soc., vol. 44, pp. 805, 1998.
    • (1998) Trans. Orthop. Res. Soc. , vol.44 , pp. 805
    • Hasan, S.S.1    Hurwitz, D.E.2    Bush-Joseph, C.A.3    Bach, B.B.J.4    Andriacchi, T.P.5
  • 13
    • 0031042280 scopus 로고    scopus 로고
    • Gait changes in older adults: Predictors of falls or indicators of fear?
    • B. E. Maki, "Gait Changes in Older Adults: Predictors of Falls or Indicators of Fear?" J. Am. Geriatr. Soc., vol. 45, no. 3, 1997.
    • (1997) J. Am. Geriatr. Soc. , vol.45 , Issue.3
    • Maki, B.E.1
  • 14
    • 12344268981 scopus 로고    scopus 로고
    • A machine learning approach for automated recognition of movement patterns using basic, kinetic and kinematic gait data
    • R. Begg and J. Kamruzzaman, "A machine learning approach for automated recognition of movement patterns using basic, kinetic and kinematic gait data," J. Biomech., vol. 38, pp. 401-408, 2005.
    • (2005) J. Biomech. , vol.38 , pp. 401-408
    • Begg, R.1    Kamruzzaman, J.2
  • 18
    • 0022676722 scopus 로고
    • Automatic computation of the screw parameters of rigid-body motions. Part I: Finitely-separated positions
    • J. Angeles, "Automatic computation of the screw parameters of rigid-body motions. Part I: Finitely-separated positions," J. Dyn. Syst.-T ASME, vol. 108, no. 1, pp. 32-38, 1986.
    • (1986) J. Dyn. Syst.-T ASME , vol.108 , Issue.1 , pp. 32-38
    • Angeles, J.1
  • 21
    • 27144489164 scopus 로고    scopus 로고
    • A tutorial on support vector machines for pattern recognition
    • C. J. Burges, "A Tutorial on Support Vector Machines for Pattern Recognition," Data Min. Knowl. Disc., vol. 2, no. 2, pp. 121-167, 1998.
    • (1998) Data Min. Knowl. Disc. , vol.2 , Issue.2 , pp. 121-167
    • Burges, C.J.1
  • 24
    • 21844468932 scopus 로고    scopus 로고
    • On the influence of soft tissue coverage in the determination of bone kinematics using skin markers
    • W. R. Taylor, et al., "On the influence of soft tissue coverage in the determination of bone kinematics using skin markers," J. Orthp. Res., vol. 23, pp. 726-734, 2005.
    • (2005) J. Orthp. Res. , vol.23 , pp. 726-734
    • Taylor, W.R.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.