메뉴 건너뛰기




Volumn 36, Issue 8, 2003, Pages 1511-1522

Novel Y(III) PVC-based membrane microelectrode based on a new S-N Schiff's base

Author keywords

Microelectrode; Potentiometry; Schiff's base; Yttrium

Indexed keywords

2 [[1,2 DIPHENYL 2 [(2,2 SULFANYLPHENYL)IMINO]ETHYLIDENE]AMINO] 1 BENZENETHIOL; ALKALI; ALKALINE EARTH METAL; EDETIC ACID; HEAVY METAL; NITROGEN; POLYVINYLCHLORIDE; SCHIFF BASE; SULFUR; UNCLASSIFIED DRUG; YTTRIUM;

EID: 0038391445     PISSN: 00032719     EISSN: None     Source Type: Journal    
DOI: 10.1081/AL-120021533     Document Type: Article
Times cited : (101)

References (20)
  • 2
    • 0001089945 scopus 로고    scopus 로고
    • Samarium(III)-selective electrode using neutral bis(thiaalkylxanthato) alkanes
    • Chowdhury, D.A.; Ogata, T.; Kamata, S. Samarium(III)-selective electrode using neutral bis(thiaalkylxanthato) alkanes. Anal. Chem. 1996, 68, 366-377.
    • (1996) Anal. Chem. , vol.68 , pp. 366-377
    • Chowdhury, D.A.1    Ogata, T.2    Kamata, S.3
  • 3
    • 4544366331 scopus 로고    scopus 로고
    • Pretsch, carrier-based ion-selective electrodes and bulk optodes E
    • Bakker, E.; Bühlamann, P.; Pretsch, carrier-based ion-selective electrodes and bulk optodes E. Chem. Rev. 1997, 97, 3083.
    • (1997) Chem. Rev. , vol.97 , pp. 3083
    • Bakker, E.1    Bühlamann, P.2
  • 4
    • 0030353029 scopus 로고    scopus 로고
    • Hydrogen chromate PVC matrix membrane sensor for potentiometric determination of chromium(III) and chromium(VI) ions
    • Saad, S.M.H.; Abbas, M.N.; Moustafa, G.A.E. Hydrogen chromate PVC matrix membrane sensor for potentiometric determination of chromium(III) and chromium(VI) ions. Talanta 1996, 43, 797-804.
    • (1996) Talanta , vol.43 , pp. 797-804
    • Saad, S.M.H.1    Abbas, M.N.2    Moustafa, G.A.E.3
  • 5
    • 0035843880 scopus 로고    scopus 로고
    • Novel potentiometric membrane sensor for selective determination of aluminium(III) ions
    • Saleh, M.B.; Saad, S.M.H.; Abdel Gaber, A.A.; Abdel Kream, N.A. Novel potentiometric membrane sensor for selective determination of aluminium(III) ions. Anal. Chim. Acta 2001, 434, 247-253.
    • (2001) Anal. Chim. Acta , vol.434 , pp. 247-253
    • Saleh, M.B.1    Saad, S.M.H.2    Abdel Gaber, A.A.3    Abdel Kream, N.A.4
  • 6
    • 0034755412 scopus 로고    scopus 로고
    • PVC-based 1,3,5-trithiane coated graphite electrode for determination of cerium(III) ions
    • Shamsipur, M.; Yousefi, M.; Hosseini, M.; Ganjali, M.R. PVC-based 1,3,5-trithiane coated graphite electrode for determination of cerium(III) ions. Anal. Lett. 2001, 34, 2249-2253.
    • (2001) Anal. Lett. , vol.34 , pp. 2249-2253
    • Shamsipur, M.1    Yousefi, M.2    Hosseini, M.3    Ganjali, M.R.4
  • 7
    • 0034213926 scopus 로고    scopus 로고
    • PVC-based 1,3,5-trithiane sensor for cerium(III) ions
    • Shamsipur, M.; Yousefi, M.; Ganjali, M.R. PVC-based 1,3,5-trithiane sensor for cerium(III) ions. Anal. Chem. 2000, 72, 2391-2394.
    • (2000) Anal. Chem. , vol.72 , pp. 2391-2394
    • Shamsipur, M.1    Yousefi, M.2    Ganjali, M.R.3
  • 10
    • 0033955839 scopus 로고    scopus 로고
    • Iron(III) ionophores based on formyl salicylic acid derivatives as sensors for ion-selective electrodes
    • Saleh, M.B. Iron(III) ionophores based on formyl salicylic acid derivatives as sensors for ion-selective electrodes. Analyst 2000, 125, 179-183.
    • (2000) Analyst , vol.125 , pp. 179-183
    • Saleh, M.B.1
  • 11
    • 0027325714 scopus 로고
    • Lipophilic and immobilized anionic additives in solvent polymeric membranes of cation-selective chemical sensor
    • Rosatzin, T.; Bakker, E.; Suzuki, K.; Simon, W. Lipophilic and immobilized anionic additives in solvent polymeric membranes of cation-selective chemical sensor. Anal. Chim. Acta 1993, 280, 197-208.
    • (1993) Anal. Chim. Acta , vol.280 , pp. 197-208
    • Rosatzin, T.1    Bakker, E.2    Suzuki, K.3    Simon, W.4
  • 12
    • 0000644872 scopus 로고    scopus 로고
    • Lead-selective membrane electrodes based on dithiophenediazacrown ether drivatives
    • Yang, X.; Kumar, M.; Chi, H.; Hibbert, D.B.; Alexander, P.W. Lead-selective membrane electrodes based on dithiophenediazacrown ether drivatives. Electroanalysis 1997, 9, 549-553.
    • (1997) Electroanalysis , vol.9 , pp. 549-553
    • Yang, X.1    Kumar, M.2    Chi, H.3    Hibbert, D.B.4    Alexander, P.W.5
  • 13
    • 0035387928 scopus 로고    scopus 로고
    • A schiff base complex of Zn(II) as a neutral carrier for highly selective PVC membrane sensors for the sulfate ion
    • Shamsipur, M.; Yousefi, M.; Hosseini, M.; Ganjali, M.R.; Sharghi, H.; Naemi, H. A schiff base complex of Zn(II) as a neutral carrier for highly selective PVC membrane sensors for the sulfate ion. Anal. Chem. 2001, 73 (13), 2869-2874.
    • (2001) Anal. Chem. , vol.73 , Issue.13 , pp. 2869-2874
    • Shamsipur, M.1    Yousefi, M.2    Hosseini, M.3    Ganjali, M.R.4    Sharghi, H.5    Naemi, H.6
  • 14
    • 0036467150 scopus 로고    scopus 로고
    • Highly selective sulfate PVC-membrane electrode based on 2,5-diphenyl-1,2,4,5-tetraaza-bicyclo[2.2.1]heptane as a neutral carrier
    • Shamsipur, M.; Yousefi, M.; Ganjali, M.R.; Poursaberi, T.; Faal-Rastgar, M. Highly selective sulfate PVC-membrane electrode based on 2,5-diphenyl-1,2,4,5-tetraaza-bicyclo[2.2.1]heptane as a neutral carrier. Sens. Actuators 2002, 82, 105-110.
    • (2002) Sens. Actuators , vol.82 , pp. 105-110
    • Shamsipur, M.1    Yousefi, M.2    Ganjali, M.R.3    Poursaberi, T.4    Faal-Rastgar, M.5
  • 16
    • 46549096850 scopus 로고
    • Lipophilic salts as membrane additives and their influence on the properties of macro- and microelectrodes based on neutral carriers
    • Ammann, D.; Pretsch, E.; Simon, W.; Lindner, E.; Bezegh, A.; Pungor, E. Lipophilic salts as membrane additives and their influence on the properties of macro- and microelectrodes based on neutral carriers. Anal. Chim. Acta 1985, 171, 119-129.
    • (1985) Anal. Chim. Acta , vol.171 , pp. 119-129
    • Ammann, D.1    Pretsch, E.2    Simon, W.3    Lindner, E.4    Bezegh, A.5    Pungor, E.6
  • 18
    • 84987539052 scopus 로고
    • Catalysis of ion transfer by tetraphenylborates in neutral carrier-based ion selective electrodes
    • Gehring, P.; Morf, W.E.; Welti, M.; Pretsch, E.; Simon, W. Catalysis of ion transfer by tetraphenylborates in neutral carrier-based ion selective electrodes. Helv. Chim. Acta 1990, 73, 203-212.
    • (1990) Helv. Chim. Acta , vol.73 , pp. 203-212
    • Gehring, P.1    Morf, W.E.2    Welti, M.3    Pretsch, E.4    Simon, W.5
  • 19
    • 84956088296 scopus 로고
    • Commission on analytical nomenclature recommendations for nomenclature for ion-selective electrodes
    • IUPAC Analytical Chemistry Division. commission on analytical nomenclature recommendations for nomenclature for ion-selective electrodes. Pure Appl. Chem. 1976, 48, 127.
    • (1976) Pure Appl. Chem. , vol.48 , pp. 127
  • 20
    • 84876596105 scopus 로고
    • Selectivity coefficients for ion-selective electrodes, recommended methods for reporting values
    • Umezawa, Y.; Umezawa, K.; Sato, H. Selectivity coefficients for ion-selective electrodes, recommended methods for reporting values. Pure Appl. Chem. 1995, 67, 507-518.
    • (1995) Pure Appl. Chem. , vol.67 , pp. 507-518
    • Umezawa, Y.1    Umezawa, K.2    Sato, H.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.