메뉴 건너뛰기




Volumn 2006, Issue , 2006, Pages 296-300

Acute performance of the thin-film longitudinal intra-fascicular electrode

Author keywords

Neural interface; Peripheral nerve; Selective recording; Thin film electrode

Indexed keywords

BIOMEDICAL ENGINEERING; NEUROLOGY; POLYIMIDES; PROSTHETICS; THIN FILMS;

EID: 33845589411     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/BIOROB.2006.1639102     Document Type: Conference Paper
Times cited : (22)

References (15)
  • 1
    • 0025818911 scopus 로고
    • Chronically implanted intrafascicular recording electrodes
    • Lefurge, T., Goodall, E., Horch, K., Stensaas, L., and Schoenberg, A., "Chronically implanted intrafascicular recording electrodes," Ann.Biomed.Eng, vol. 19, no. 2, pp. 197-207, 1991.
    • (1991) Ann. Biomed. Eng , vol.19 , Issue.2 , pp. 197-207
    • Lefurge, T.1    Goodall, E.2    Horch, K.3    Stensaas, L.4    Schoenberg, A.5
  • 2
    • 0026229639 scopus 로고
    • Information contained in sensory nerve recordings made with intrafascicular electrodes
    • Sept.
    • Goodall, E. V., Lefurge, T. M., and Horch, K. W., "Information contained in sensory nerve recordings made with intrafascicular electrodes," IEEE Trans.Biomed.Eng, vol. 38, no. 9, pp. 846-850, Sept.1991.
    • (1991) IEEE Trans. Biomed. Eng , vol.38 , Issue.9 , pp. 846-850
    • Goodall, E.V.1    Lefurge, T.M.2    Horch, K.W.3
  • 3
    • 0026833038 scopus 로고
    • Separation of action potentials in multiunit intrafascicular recordings
    • Mar.
    • Goodall, E. V. and Horch, K. W., "Separation of action potentials in multiunit intrafascicular recordings.," IEEE Transactions on Biomedical Engineering, vol. 39, no. 3, pp. 289-295, Mar.1992.
    • (1992) IEEE Transactions on Biomedical Engineering , vol.39 , Issue.3 , pp. 289-295
    • Goodall, E.V.1    Horch, K.W.2
  • 5
    • 0032957207 scopus 로고    scopus 로고
    • Characterization of signals and noise rejection with bipolar longitudinal intrafascicular electrodes
    • Feb.
    • Yoshida, K. and Stein, R. B., "Characterization of signals and noise rejection with bipolar longitudinal intrafascicular electrodes," IEEE Trans.Biomed.Eng, vol. 46, no. 2, pp. 226-234, Feb. 1999.
    • (1999) IEEE Trans.Biomed.Eng , vol.46 , Issue.2 , pp. 226-234
    • Yoshida, K.1    Stein, R.B.2
  • 6
    • 0026206943 scopus 로고
    • Muscle recruitment with intrafascicular electrodes
    • Aug.
    • Nannini, N. and Horch, K., "Muscle recruitment with intrafascicular electrodes.," IEEE Transactions on Biomedical Engineering, vol. 38, no. 8, pp. 769-776, Aug. 1991.
    • (1991) IEEE Transactions on Biomedical Engineering , vol.38 , Issue.8 , pp. 769-776
    • Nannini, N.1    Horch, K.2
  • 7
    • 0027588996 scopus 로고
    • Selective stimulation of peripheral nerve fibers using dual intrafascicular electrodes
    • May
    • Yoshida, K. and Horch, K., "Selective stimulation of peripheral nerve fibers using dual intrafascicular electrodes.," IEEE Transactions on Biomedical Engineering, vol. 40, no. 5, pp. 492-494, May1993.
    • (1993) IEEE Transactions on Biomedical Engineering , vol.40 , Issue.5 , pp. 492-494
    • Yoshida, K.1    Horch, K.2
  • 8
    • 3142743126 scopus 로고    scopus 로고
    • Residual function in peripheral nerve stumps of amputees: Implications for neural control of artificial limbs
    • July
    • Dhillon, G. S., Lawrence, S. M., Hutchinson, D. T., and Horch, K. W., "Residual function in peripheral nerve stumps of amputees: implications for neural control of artificial limbs," J Hand Surg.[Am.], vol. 29, no. 4, pp. 605-615, July2004.
    • (2004) J Hand Surg.[Am.] , vol.29 , Issue.4 , pp. 605-615
    • Dhillon, G.S.1    Lawrence, S.M.2    Hutchinson, D.T.3    Horch, K.W.4
  • 9
    • 17744366189 scopus 로고    scopus 로고
    • Effects of short-term training on sensory and motor function in severed nerves of long-term human amputees
    • May
    • Dhillon, G. S., Kruger, T. B., Sandhu, J. S., and Horch, K. W., "Effects of short-term training on sensory and motor function in severed nerves of long-term human amputees," J Neurophysiol., vol. 93, no. 5, pp. 2625-2633, May2005.
    • (2005) J Neurophysiol. , vol.93 , Issue.5 , pp. 2625-2633
    • Dhillon, G.S.1    Kruger, T.B.2    Sandhu, J.S.3    Horch, K.W.4
  • 10
    • 0036381714 scopus 로고    scopus 로고
    • Long-term biocompatibility of implanted polymer-based intrafascicular electrodes
    • Lawrence, S. M., Larsen, J. O., Horch, K. W., Riso, R., and Sinkjaer, T., "Long-term biocompatibility of implanted polymer-based intrafascicular electrodes," J.Biomed.Mater.Res., vol. 63, no. 5, pp. 501-506, 2002.
    • (2002) J.Biomed.Mater.Res. , vol.63 , Issue.5 , pp. 501-506
    • Lawrence, S.M.1    Larsen, J.O.2    Horch, K.W.3    Riso, R.4    Sinkjaer, T.5
  • 14
    • 33845590400 scopus 로고    scopus 로고
    • New technologies in manufacturing of different implantable micro electrodes as an interface to the peripheral nervous system
    • Hoffmann, K. P., Koch, K. P., Dörge, T., and Micera, S. New technologies in manufacturing of different implantable micro electrodes as an interface to the peripheral nervous system. Proc.BioRob2006. 2006.
    • (2006) Proc.BioRob2006.
    • Hoffmann, K.P.1    Koch, K.P.2    Dörge, T.3    Micera, S.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.