메뉴 건너뛰기




Volumn 6, Issue , 2006, Pages

Imaging corticospinal tract connectivity in injured rat spinal cord using manganese-enhanced MRI

Author keywords

[No Author keywords available]

Indexed keywords

MANGANESE CHLORIDE;

EID: 33845455457     PISSN: 14712342     EISSN: 14712342     Source Type: Journal    
DOI: 10.1186/1471-2342-6-15     Document Type: Article
Times cited : (26)

References (15)
  • 3
    • 0036436365 scopus 로고    scopus 로고
    • Reorganization of descending motor tracts in the rat spinal cord
    • Raineteau O, Fouad K, Bareyre FM, Schwab ME: Reorganization of descending motor tracts in the rat spinal cord. Eur J Neurosci 2002, 16(9):1761-1771.
    • (2002) Eur J Neurosci , vol.16 , Issue.9 , pp. 1761-1771
    • Raineteau, O.1    Fouad, K.2    Bareyre, F.M.3    Schwab, M.E.4
  • 4
    • 0034869395 scopus 로고    scopus 로고
    • A novel method for simultaneous anterograde and retrograde labeling of spinal cord motor tracts in the same animal
    • Tsai EC, van Bendegem RL, Hwang SW, Tator CH: A novel method for simultaneous anterograde and retrograde labeling of spinal cord motor tracts in the same animal. J Histochem Cytochem 2001, 49(9):1111-1122.
    • (2001) J Histochem Cytochem , vol.49 , Issue.9 , pp. 1111-1122
    • Tsai, E.C.1    van Bendegem, R.L.2    Hwang, S.W.3    Tator, C.H.4
  • 5
    • 0033962518 scopus 로고    scopus 로고
    • Recent techniques for tracing pathways in the central nervous system of developing and adult mammals
    • Vercelli A, Repici M, Garbossa D, Grimaldi A: Recent techniques for tracing pathways in the central nervous system of developing and adult mammals. Brain Res Bull 2000, 51(1):11-28.
    • (2000) Brain Res Bull , vol.51 , Issue.1 , pp. 11-28
    • Vercelli, A.1    Repici, M.2    Garbossa, D.3    Grimaldi, A.4
  • 6
    • 28644436113 scopus 로고    scopus 로고
    • Transgenic labeling of the corticospinal tract for monitoring axonal responses to spinal cord injury
    • Bareyre FM, Kerschensteiner M, Misgeld T, Sanes JR: Transgenic labeling of the corticospinal tract for monitoring axonal responses to spinal cord injury. Nat Med 2005, 11(12):1355-1360.
    • (2005) Nat Med , vol.11 , Issue.12 , pp. 1355-1360
    • Bareyre, F.M.1    Kerschensteiner, M.2    Misgeld, T.3    Sanes, J.R.4
  • 8
    • 33745750132 scopus 로고    scopus 로고
    • Electrical stimulation of cortex improves corticospinal tract tracing in rat spinal cord using manganese-enhanced MRI
    • Bilgen M, Peng W, Al-Hafez B, Dancause N, He YY, Cheney PD: Electrical stimulation of cortex improves corticospinal tract tracing in rat spinal cord using manganese-enhanced MRI. J Neurosci Methods 2006.
    • (2006) J Neurosci Methods
    • Bilgen, M.1    Peng, W.2    Al-Hafez, B.3    Dancause, N.4    He, Y.Y.5    Cheney, P.D.6
  • 9
    • 24044458211 scopus 로고    scopus 로고
    • A new device for experimental modeling of central nervous system injuries
    • Bilgen M: A new device for experimental modeling of central nervous system injuries. Neurorehabil Neural Repair 2005, 19(3):219-226.
    • (2005) Neurorehabil Neural Repair , vol.19 , Issue.3 , pp. 219-226
    • Bilgen, M.1
  • 10
    • 20344394129 scopus 로고    scopus 로고
    • Ex vivo magnetic resonance imaging of rat spinal cord at 9.4 T
    • T MM, I VS
    • Bilgen M, Al-Hafez B, T MM, I VS: Ex vivo magnetic resonance imaging of rat spinal cord at 9.4 T. Magn Reson Imaging 2005, 23(4):601-605.
    • (2005) Magn Reson Imaging , vol.23 , Issue.4 , pp. 601-605
    • Bilgen, M.1    Al-Hafez, B.2
  • 11
    • 32844461622 scopus 로고    scopus 로고
    • IR-SE and IR-MEMRI allow in vivo visualization of oscine neuroarchitecture including the main forebrain regions of the song control system
    • Tindemans I, Boumans T, Verhoye M, Van der Linden A: IR-SE and IR-MEMRI allow in vivo visualization of oscine neuroarchitecture including the main forebrain regions of the song control system. NMR Biomed 2006, 19(1):18-29.
    • (2006) NMR Biomed , vol.19 , Issue.1 , pp. 18-29
    • Tindemans, I.1    Boumans, T.2    Verhoye, M.3    Van der Linden, A.4
  • 12
    • 4744349564 scopus 로고    scopus 로고
    • Simple, low-cost multipurpose RF coil for MR microscopy at 9.4 T
    • Bilgen M: Simple, low-cost multipurpose RF coil for MR microscopy at 9.4 T. Magn Reson Med 2004, 52(4):937-940.
    • (2004) Magn Reson Med , vol.52 , Issue.4 , pp. 937-940
    • Bilgen, M.1
  • 14
    • 0035166631 scopus 로고    scopus 로고
    • Validation of diffusion tensor magnetic resonance axonal fiber imaging with registered manganese-enhanced optic tracts
    • Lin CP, Tseng WY, Cheng HC, Chen JH: Validation of diffusion tensor magnetic resonance axonal fiber imaging with registered manganese-enhanced optic tracts. Neuroimage 2001, 14(5):1035-1047.
    • (2001) Neuroimage , vol.14 , Issue.5 , pp. 1035-1047
    • Lin, C.P.1    Tseng, W.Y.2    Cheng, H.C.3    Chen, J.H.4
  • 15
    • 0041806856 scopus 로고    scopus 로고
    • Mohr diagram interpretation of anisotropic diffusion indices in MRI
    • Bilgen M, Narayana PA: Mohr diagram interpretation of anisotropic diffusion indices in MRI. Magn Reson Imaging 2003, 21(5):567-572.
    • (2003) Magn Reson Imaging , vol.21 , Issue.5 , pp. 567-572
    • Bilgen, M.1    Narayana, P.A.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.