Impedance cardiography: More questions than answers

Author keywords

[No Author keywords available]

Indexed keywords

ANGIOTENSIN 2 RECEPTOR ANTAGONIST; BETA ADRENERGIC RECEPTOR BLOCKING AGENT; CALCIUM CHANNEL BLOCKING AGENT; DIPEPTIDYL CARBOXYPEPTIDASE INHIBITOR; DIURETIC AGENT; VASODILATOR AGENT;

EID: 33845439357     PISSN: 15469530     EISSN: 15469549     Source Type: Journal    
DOI: 10.1007/s11897-006-0009-7     Document Type: Review
Times cited : (16)

References (53)
  • 1
    • 0033170999 scopus 로고    scopus 로고
    • Electrophysiologic principles and theory of stroke volume determination by thoracic electrical bioimpedance
    • Osypka MJ, Bernstein DP: Electrophysiologic principles and theory of stroke volume determination by thoracic electrical bioimpedance. AACN Clin issues 1999, 10:385-395. A fairly technical article that details the development of ICG theory and contains an appendix on basic electrical theory.
    • (1999) AACN Clin Issues , vol.10 , pp. 385-395
    • Osypka, M.J.1    Bernstein, D.P.2
  • 2
    • 0029825393 scopus 로고    scopus 로고
    • Impedance cardiography. Importance of the equation and the electrode configuration
    • van der Meer BJ, Woltjer HH, Sousman AM, et al.: Impedance cardiography. Importance of the equation and the electrode configuration. Intensive Care Med 1996, 22:1120-1124.
    • (1996) Intensive Care Med , vol.22 , pp. 1120-1124
    • Van Der Meer, B.J.1    Woltjer, H.H.2    Sousman, A.M.3
  • 3
    • 0013978742 scopus 로고
    • Development and evaluation of an impedance cardiac output system
    • Kubicek WG, Karnegis JN, Patterson RP, et al.: Development and evaluation of an impedance cardiac output system. Aerosp Med 1966, 37:1208-1212.
    • (1966) Aerosp Med , vol.37 , pp. 1208-1212
    • Kubicek, W.G.1    Karnegis, J.N.2    Patterson, R.P.3
  • 4
    • 0026547308 scopus 로고
    • Esophageal electrodes allow precise assessment of cardiac output by bioimpedance
    • Balestra B, Malacrida R, Leonardi L, et al.: Esophageal electrodes allow precise assessment of cardiac output by bioimpedance. Crit Care Med 1992, 20:62-67.
    • (1992) Crit Care Med , vol.20 , pp. 62-67
    • Balestra, B.1    Malacrida, R.2    Leonardi, L.3
  • 5
    • 0030477530 scopus 로고    scopus 로고
    • Standardization of non-invasive impedance cardiography for assessment of stroke volume: Comparison with thermodilution
    • Woltjer HH, Bogaard HJ, Scheffer GJ, et al.: Standardization of non-invasive impedance cardiography for assessment of stroke volume: comparison with thermodilution. Br J Anaesth 1996, 77:748-752.
    • (1996) Br J Anaesth , vol.77 , pp. 748-752
    • Woltjer, H.H.1    Bogaard, H.J.2    Scheffer, G.J.3
  • 6
    • 0001952126 scopus 로고
    • Stroke volume equation with a linear base impedance model and its accuracy as compared to thermodilution and magnetic flowmeter techniques in humans and animals
    • Zadar, Yugoslovia; September 12-14
    • Sramek BB, Rose DM, Miyamoto A: Stroke volume equation with a linear base impedance model and its accuracy as compared to thermodilution and magnetic flowmeter techniques in humans and animals. Proceedings of the Sixth International Conference on Electrical Bioimpedance. Zadar, Yugoslovia; September 12-14, 1983.
    • (1983) Proceedings of the Sixth International Conference on Electrical Bioimpedance
    • Sramek, B.B.1    Rose, D.M.2    Miyamoto, A.3
  • 7
    • 0022980897 scopus 로고
    • New stroke volume equation for thoracic electrical bioimpedance: Theory and rationale
    • Bernstein DP: New stroke volume equation for thoracic electrical bioimpedance: theory and rationale. Crit Care Med 1986, 14:904-909.
    • (1986) Crit Care Med , vol.14 , pp. 904-909
    • Bernstein, D.P.1
  • 8
    • 0033009507 scopus 로고    scopus 로고
    • A meta-analysis of three decades of validating thoracic impedance cardiography
    • Raaijmakers E, Faes TJ, Scholten RJ, et al.: A meta-analysis of three decades of validating thoracic impedance cardiography. Crit Care Med 1999, 27:1203-1213. Meta-analysis from 1999 summarizing data available at that time.
    • (1999) Crit Care Med , vol.27 , pp. 1203-1213
    • Raaijmakers, E.1    Faes, T.J.2    Scholten, R.J.3
  • 9
    • 0038385882 scopus 로고    scopus 로고
    • Impedance cardiography: The next vital sign technology?
    • van de Water JVD, Miller T, Vogel R, et al.: Impedance cardiography: the next vital sign technology? Chest 2003, 123:2028-2033.
    • (2003) Chest , vol.123 , pp. 2028-2033
    • Van De Water, J.V.D.1    Miller, T.2    Vogel, R.3
  • 10
    • 0036171177 scopus 로고    scopus 로고
    • Equivalence of bioimpedance and thermodilution in measuring cardiac index after cardiac surgery
    • Sageman WS, Riffenburgh RH, Spiess BD: Equivalence of bioimpedance and thermodilution in measuring cardiac index after cardiac surgery. J Cardiothorac Vasc Anesth 2002, 16:8-14.
    • (2002) J Cardiothorac Vasc Anesth , vol.16 , pp. 8-14
    • Sageman, W.S.1    Riffenburgh, R.H.2    Spiess, B.D.3
  • 11
    • 12144256186 scopus 로고    scopus 로고
    • Comparison of cardiac output determined by bioimpedance, thermodilution, and the Fick method
    • Engoren M, Barbee D: Comparison of cardiac output determined by bioimpedance, thermodilution, and the Fick method. Am J Crit Care 2005, 14:40-45.
    • (2005) Am J Crit Care , vol.14 , pp. 40-45
    • Engoren, M.1    Barbee, D.2
  • 12
    • 0032247707 scopus 로고    scopus 로고
    • Multicenter study of noninvasive monitoring systems as alternatives to invasive monitoring of acutely ill emergency patients
    • Shoemaker WC, Belzberg H, Wo CC, et al.: Multicenter study of noninvasive monitoring systems as alternatives to invasive monitoring of acutely ill emergency patients. Chest 1998, 114:1643-1652.
    • (1998) Chest , vol.114 , pp. 1643-1652
    • Shoemaker, W.C.1    Belzberg, H.2    Wo, C.C.3
  • 13
    • 33750665574 scopus 로고    scopus 로고
    • Comparison of the use of the pulmonary artery catheter versus thoracic electrical bioimpedance in a medical intensive care unit
    • Ziegler D, Grotti L, Krucke G: Comparison of the use of the pulmonary artery catheter versus thoracic electrical bioimpedance in a medical intensive care unit. Crit Care Med 1999, 27(Suppl S):223
    • (1999) Crit Care Med , vol.27 , Issue.SUPPL. S , pp. 223
    • Ziegler, D.1    Grotti, L.2    Krucke, G.3
  • 14
    • 8644266685 scopus 로고    scopus 로고
    • Equivalence of the bioimpedance and thermodilution methods in measuring cardiac output in hospitalized patients with advanced, decompensated chronic heart failure
    • Albert NM, Hail MD, Li J, Young JB: Equivalence of the bioimpedance and thermodilution methods in measuring cardiac output in hospitalized patients with advanced, decompensated chronic heart failure. Am J Crit Care 2004, 13:469-479.
    • (2004) Am J Crit Care , vol.13 , pp. 469-479
    • Albert, N.M.1    Hail, M.D.2    Li, J.3    Young, J.B.4
  • 15
    • 0037090669 scopus 로고    scopus 로고
    • Comparison of impedance cardiography with invasive hemodynamic measurements in patients with heart failure secondary to ischemic or nonischemic cardiomyopathy
    • 2. The authors also note poor correlation between TFC and wedge pressure.
    • (2002) Am J Cardiol , vol.89 , pp. 993-995
    • Drazner, M.H.1    Thompson, B.2    Rosenberg, P.B.3
  • 16
    • 33646386315 scopus 로고    scopus 로고
    • Bioimpedance monitoring in patients with chronic heart failure
    • Funk M, Nystrom KV, Hutchinson C, et al.: Bioimpedance monitoring in patients with chronic heart failure. J Cardiac Fail 2003, 9(5 Suppl): S6.
    • (2003) J Cardiac Fail , vol.9 , Issue.5 SUPPL.
    • Funk, M.1    Nystrom, K.V.2    Hutchinson, C.3
  • 17
    • 33646426816 scopus 로고    scopus 로고
    • Diagnostic implications of impedance cardiography in the setting of severe acute decompensated heart failure: Results of the bioimpedance cardiography (BIG) substudy in the ESCAPE trial
    • Yancy CW, Rogers J, Pauly DF, et al.: Diagnostic implications of impedance cardiography in the setting of severe acute decompensated heart failure: results of the bioimpedance cardiography (BIG) substudy in the ESCAPE trial. Circulation 2005, 112:11-639-11-640. The largest and highest quality study correlating ICG measurements to PAC measurements. Currently in abstract form, the final manuscript detailing poor correlation with PAC measurements should be interesting.
    • (2005) Circulation , vol.112 , pp. 11639-11640
    • Yancy, C.W.1    Rogers, J.2    Pauly, D.F.3
  • 18
    • 0026409914 scopus 로고
    • Non-invasive measurement of cardiac output by thoracic electrical bioimpedance: A study of reproducibility and comparison with thermodilution
    • Jewkes C, Sear JW, Verhoeff F, et al.: Non-invasive measurement of cardiac output by thoracic electrical bioimpedance: a study of reproducibility and comparison with thermodilution. Br J Anaesth 1991, 67:788-794.
    • (1991) Br J Anaesth , vol.67 , pp. 788-794
    • Jewkes, C.1    Sear, J.W.2    Verhoeff, F.3
  • 19
    • 0029907058 scopus 로고    scopus 로고
    • The influence of weight on stroke volume determination by means of impedance cardiography in cardiac surgery patients
    • Woltjer HH, Bogaard HJ, van der Spoel HI, de Vries PM: The influence of weight on stroke volume determination by means of impedance cardiography in cardiac surgery patients. Intensive Care Med 1996, 22:766-771.
    • (1996) Intensive Care Med , vol.22 , pp. 766-771
    • Woltjer, H.H.1    Bogaard, H.J.2    Van Der Spoel, H.I.3    De Vries, P.M.4
  • 20
    • 18844386766 scopus 로고    scopus 로고
    • Functional valvular incompetence in decompensated heart failure: Noninvasive monitoring and response to medical management
    • Campos PC, D'Cruz IA, Johnson LS, et al.: Functional valvular incompetence in decompensated heart failure: noninvasive monitoring and response to medical management. Am J Med Sci 2005, 329:217-221.
    • (2005) Am J Med Sci , vol.329 , pp. 217-221
    • Campos, P.C.1    D'Cruz, I.A.2    Johnson, L.S.3
  • 21
    • 3042825525 scopus 로고    scopus 로고
    • Comparison of changes in ejection fraction to changes in impedance cardiography cardiac index and systolic time ratio
    • Parrott CW, Burnham KM, Quale C, Lewis DL: Comparison of changes in ejection fraction to changes in impedance cardiography cardiac index and systolic time ratio. Congest Heart Fail 2004, 10(2 Suppl 2):11-13.
    • (2004) Congest Heart Fail , vol.10 , Issue.2 SUPPL. 2 , pp. 11-13
    • Parrott, C.W.1    Burnham, K.M.2    Quale, C.3    Lewis, D.L.4
  • 22
    • 24944488027 scopus 로고    scopus 로고
    • Method and demonstration of direct confirmation of response to cardiac resynchronization therapy via preimplant temporary biventricular pacing and impedance cardiography
    • Gimbel JR: Method and demonstration of direct confirmation of response to cardiac resynchronization therapy via preimplant temporary biventricular pacing and impedance cardiography. Am J Cardiol 2005, 96:874-876.
    • (2005) Am J Cardiol , vol.96 , pp. 874-876
    • Gimbel, J.R.1
  • 23
    • 7944230371 scopus 로고    scopus 로고
    • Impedance cardiography for acute pacing AV optimization
    • Johnson W, Voegtlin L, Bailin, SJ, Hoyt RH: Impedance cardiography for acute pacing AV optimization. J Card Fail 2001, 7(Suppl 2):52.
    • (2001) J Card Fail , vol.7 , Issue.SUPPL. 2 , pp. 52
    • Johnson, W.1    Voegtlin, L.2    Bailin, S.J.3    Hoyt, R.H.4
  • 24
    • 0037247636 scopus 로고    scopus 로고
    • Impedance cardiography for atrioventricular interval optimization during permanent left ventricular pacing
    • Tse HF, Yu C, Park E, Lau CP: Impedance cardiography for atrioventricular interval optimization during permanent left ventricular pacing. Pacing Clin Electrophysiol 2003, 26(1 Part 2):189-191.
    • (2003) Pacing Clin Electrophysiol , vol.26 , Issue.1 PART 2 , pp. 189-191
    • Tse, H.F.1    Yu, C.2    Park, E.3    Lau, C.P.4
  • 25
    • 0028306040 scopus 로고
    • Electrical impedance measured changes in thoracic fluid content during thoracentesis
    • Petersen JR, Jensen BV, Drabaek H, et al.: Electrical impedance measured changes in thoracic fluid content during thoracentesis. Clin Physiol 1994, 15:459-466.
    • (1994) Clin Physiol , vol.15 , pp. 459-466
    • Petersen, J.R.1    Jensen, B.V.2    Drabaek, H.3
  • 26
    • 14744282940 scopus 로고    scopus 로고
    • Reproducibility of impedance cardiography parameters in outpatients with clinically stable coronary artery disease
    • Treister N, Wagner K, Jansen PR: Reproducibility of impedance cardiography parameters in outpatients with clinically stable coronary artery disease. Am J Hypertens 2005, 18(2 Part 2):44S-50S.
    • (2005) Am J Hypertens , vol.18 , Issue.2 PART 2
    • Treister, N.1    Wagner, K.2    Jansen, P.R.3
  • 27
    • 0347325156 scopus 로고    scopus 로고
    • Reproducibility of noninvasive bioimpedance measurements of cardiac function
    • Verhoeve PE, Cadwell CA: Reproducibility of noninvasive bioimpedance measurements of cardiac function. J Card Fail 1998, 4(Suppl 1):53.
    • (1998) J Card Fail , vol.4 , Issue.SUPPL. 1 , pp. 53
    • Verhoeve, P.E.1    Cadwell, C.A.2
  • 28
    • 0034426946 scopus 로고    scopus 로고
    • Reproducibility of impedance cardiography hemodynamic measures in clinically stable heart failure patients
    • Greenberg BH, Hermann DD, Pranulis MF, et al.: Reproducibility of impedance cardiography hemodynamic measures in clinically stable heart failure patients. Congest Heart Fail 2000, 6:74-80.
    • (2000) Congest Heart Fail , vol.6 , pp. 74-80
    • Greenberg, B.H.1    Hermann, D.D.2    Pranulis, M.F.3
  • 29
    • 33645310534 scopus 로고    scopus 로고
    • Clinical utility of impedance cardiography in diagnosing congestive heart failure
    • Han J, Lindsell C, Tsurov A, Storrow AB: Clinical utility of impedance cardiography in diagnosing congestive heart failure. Acad Emerg Med 2002, 9:439-440.
    • (2002) Acad Emerg Med , vol.9 , pp. 439-440
    • Han, J.1    Lindsell, C.2    Tsurov, A.3    Storrow, A.B.4
  • 30
    • 22644438455 scopus 로고    scopus 로고
    • Noninvasive bioimpedance monitoring differentiates cardiogenic from pulmonary causes of acute dyspnea in the emergency department
    • Marrocco A, Eskin B, Nashed AH, et al.: Noninvasive bioimpedance monitoring differentiates cardiogenic from pulmonary causes of acute dyspnea in the emergency department. Acad Emerg Med 1998, 5:476-477.
    • (1998) Acad Emerg Med , vol.5 , pp. 476-477
    • Marrocco, A.1    Eskin, B.2    Nashed, A.H.3
  • 31
    • 3042786485 scopus 로고    scopus 로고
    • Utility of impedance cardiography to determine cardiac vs. noncardiac cause of dyspnea in the emergency department
    • Springfield CL, Sebat F, Johnson D, et al.: Utility of impedance cardiography to determine cardiac vs. noncardiac cause of dyspnea in the emergency department. Congest Heart Fail 2004, 10(2 Suppl 2):14-16.
    • (2004) Congest Heart Fail , vol.10 , Issue.2 SUPPL. 2 , pp. 14-16
    • Springfield, C.L.1    Sebat, F.2    Johnson, D.3
  • 32
    • 14744286067 scopus 로고    scopus 로고
    • Combination of B-type natriuretic peptide levels and non-invasive hemodynamic parameters in diagnosing congestive heart failure in the emergency department
    • Barcarse E, Kazanegra R, Chen A, et al.: Combination of B-type natriuretic peptide levels and non-invasive hemodynamic parameters in diagnosing congestive heart failure in the emergency department. Congest Heart Fail 2004, 10:171-176.
    • (2004) Congest Heart Fail , vol.10 , pp. 171-176
    • Barcarse, E.1    Kazanegra, R.2    Chen, A.3
  • 33
    • 33646430232 scopus 로고    scopus 로고
    • Impedance cardiography in heart failure patients in the intensive care unit: Its value in the detection of left ventricular systolic dysfunction and correlation with the echocardiogram
    • Ramirez MFL, Yamamoto ME, Caguioa EVS: Impedance cardiography in heart failure patients in the intensive care unit: its value in the detection of left ventricular systolic dysfunction and correlation with the echocardiogram. J Am Coll Cardiol 2004, 43(5 Suppl A):207A.
    • (2004) J Am Coll Cardiol , vol.43 , Issue.5 SUPPL. A
    • Ramirez, M.F.L.1    Yamamoto, M.E.2    Caguioa, E.V.S.3
  • 34
    • 14744299646 scopus 로고    scopus 로고
    • Is impedance cardiography-derived systolic time ratio a useful method to determine left ventricular systolic dysfunction in heart failure
    • Thompson B, Drazner MH, Dries DL, Yancy CW: Is impedance cardiography-derived systolic time ratio a useful method to determine left ventricular systolic dysfunction in heart failure. J Card Fail 2004, 10(Suppl 4):S38.
    • (2004) J Card Fail , vol.10 , Issue.SUPPL. 4
    • Thompson, B.1    Drazner, M.H.2    Dries, D.L.3    Yancy, C.W.4
  • 35
    • 0003447880 scopus 로고    scopus 로고
    • The utility of thoracic impedance to evaluate chest radiograph changes from acute heart failure patients in the emergency department
    • Milzman DP, Hogan C, Zlindenny A, et al.: The utility of thoracic impedance to evaluate chest radiograph changes from acute heart failure patients in the emergency department. J Card Fail 1998, 4(Suppl 1):37.
    • (1998) J Card Fail , vol.4 , Issue.SUPPL. 1 , pp. 37
    • Milzman, D.P.1    Hogan, C.2    Zlindenny, A.3
  • 36
    • 0034426920 scopus 로고    scopus 로고
    • Bioimpedance monitoring: Better than chest x-ray for predicting abnormal pulmonary fluid?
    • Peacock WF, Albert NM, Kies P, et al.: Bioimpedance monitoring: better than chest x-ray for predicting abnormal pulmonary fluid? Congest Heart Fail 1999, 6:86-89.
    • (1999) Congest Heart Fail , vol.6 , pp. 86-89
    • Peacock, W.F.1    Albert, N.M.2    Kies, P.3
  • 37
    • 20444380846 scopus 로고    scopus 로고
    • Emergent dyspnea impedance cardiography-aided assessment changes therapy: The ED-IMPACT trial
    • Peacock W, Summers R, Emerman C: Emergent dyspnea impedance cardiography-aided assessment changes therapy: the ED-IMPACT trial. Ann Emerg Med 2003, 42:582.
    • (2003) Ann Emerg Med , vol.42 , pp. 582
    • Peacock, W.1    Summers, R.2    Emerman, C.3
  • 38
    • 26044460566 scopus 로고    scopus 로고
    • Evaluation study of congestive heart failure and pulmonary artery catheterization effectiveness: The ESCAPE trial
    • Binanay C, Califf RM, Hasselblad V, et al.: Evaluation study of congestive heart failure and pulmonary artery catheterization effectiveness: the ESCAPE trial. JAMA 2005, 294:1625-1633. A well-controlled study that shows having hemodynamic information does not necessarily lead to better outcomes.
    • (2005) JAMA , vol.294 , pp. 1625-1633
    • Binanay, C.1    Califf, R.M.2    Hasselblad, V.3
  • 39
    • 0028951035 scopus 로고
    • Time course of improvement in left ventricular function, mass and geometry in patients with congestive heart failure treated with beta-adrenergic blockade
    • Hall SA, Cigarroa CG, Marcoux L, et al.: Time course of improvement in left ventricular function, mass and geometry in patients with congestive heart failure treated with beta-adrenergic blockade. J Am Coll Cardiol 1995, 25:1154-1161.
    • (1995) J Am Coll Cardiol , vol.25 , pp. 1154-1161
    • Hall, S.A.1    Cigarroa, C.G.2    Marcoux, L.3
  • 40
    • 0037181515 scopus 로고    scopus 로고
    • Short-term intravenous milrinone for acute exacerbation of chronic heart failure: A randomized controlled trial
    • Cuffe MS, Califf RM, Adams KF Jr, et al.: Short-term intravenous milrinone for acute exacerbation of chronic heart failure: a randomized controlled trial. JAMA 2002, 287:1541-1547.
    • (2002) JAMA , vol.287 , pp. 1541-1547
    • Cuffe, M.S.1    Califf, R.M.2    Adams Jr., K.F.3
  • 41
    • 0038342705 scopus 로고    scopus 로고
    • Outpatient cardiovascular management utilizing impedance cardiography
    • Lasater M, Von Rueden KT: Outpatient cardiovascular management utilizing impedance cardiography. AACN Clin Issues 2003, 14:240-250.
    • (2003) AACN Clin Issues , vol.14 , pp. 240-250
    • Lasater, M.1    Von Rueden, K.T.2
  • 42
    • 14744287524 scopus 로고    scopus 로고
    • Use of systolic time ratio and B-type natriuretic peptide to predict mortality in patients with heart failure
    • Zewail A, Broom C, Eastwood C, et al.: Use of systolic time ratio and B-type natriuretic peptide to predict mortality in patients with heart failure. J Card Fail 2003, 9(Suppl):S105.
    • (2003) J Card Fail , vol.9 , Issue.SUPPL.
    • Zewail, A.1    Broom, C.2    Eastwood, C.3
  • 43
    • 33646407203 scopus 로고    scopus 로고
    • Utility of impedance cardiography for the identification of short-term risk of clinical decompensation in stable patients with chronic heart failure
    • in press
    • Packer M, Abraham WT, Mehra MR, et al.: Utility of impedance cardiography for the identification of short-term risk of clinical decompensation in stable patients with chronic heart failure. J Am Coll Cardiol 2006, in press.
    • (2006) J Am Coll Cardiol
    • Packer, M.1    Abraham, W.T.2    Mehra, M.R.3
  • 44
    • 0027443446 scopus 로고
    • Registration of thoracic electrical bioimpedance for early diagnosis of rejection after heart transplantation
    • Weinhold C, Reichenspurner H, Fulle P, et al.: Registration of thoracic electrical bioimpedance for early diagnosis of rejection after heart transplantation. J Heart Lung Transplant 1993, 12:832-836.
    • (1993) J Heart Lung Transplant , vol.12 , pp. 832-836
    • Weinhold, C.1    Reichenspurner, H.2    Fulle, P.3
  • 45
    • 0031439024 scopus 로고    scopus 로고
    • The importance of the left atrioventricular interval during atrioventricular sequential pacing
    • Chevalier S, Basta M, Leitch JW: The importance of the left atrioventricular interval during atrioventricular sequential pacing. Pacing Clin Electrophysiol 1997, 20(12 Part 1):2958-2966.
    • (1997) Pacing Clin Electrophysiol , vol.20 , Issue.12 PART 1 , pp. 2958-2966
    • Chevalier, S.1    Basta, M.2    Leitch, J.W.3
  • 46
    • 0030858277 scopus 로고    scopus 로고
    • Systolic and diastolic effects of variable atrioventricular delay in patients with complete heart block and normal ventricular function
    • Leonelli FM, Wang K, Youssef M, et al.: Systolic and diastolic effects of variable atrioventricular delay in patients with complete heart block and normal ventricular function. Am J Cardiol 1997, 80:294-298.
    • (1997) Am J Cardiol , vol.80 , pp. 294-298
    • Leonelli, F.M.1    Wang, K.2    Youssef, M.3
  • 47
    • 0028876281 scopus 로고
    • Dual-chamber pacing with a short atrioventricular delay in congestive heart failure: A randomized study
    • Gold MR, Feliciano Z, Gottlieb SS, Fisher ML: Dual-chamber pacing with a short atrioventricular delay in congestive heart failure: a randomized study. J Am Coll Cardiol 1995, 26:967-973.
    • (1995) J Am Coll Cardiol , vol.26 , pp. 967-973
    • Gold, M.R.1    Feliciano, Z.2    Gottlieb, S.S.3    Fisher, M.L.4
  • 48
    • 0039543337 scopus 로고    scopus 로고
    • Atrioventricular interval optimization technique: Impedance measurements vs. echo/Doppler
    • Hayes DL, Hayes SN, Hyberger LK: Atrioventricular interval optimization technique: impedance measurements vs. echo/Doppler. Pacing Clin Electrophysiol 1998, 21:969.
    • (1998) Pacing Clin Electrophysiol , vol.21 , pp. 969
    • Hayes, D.L.1    Hayes, S.N.2    Hyberger, L.K.3
  • 49
    • 7944233622 scopus 로고    scopus 로고
    • Atrioventricular interval optimization after biventricular pacing: Echo/Doppler vs. impedance plethysmography
    • Hayes DL, Hayes SN, Hyberger LK, et al.: Atrioventricular interval optimization after biventricular pacing: echo/Doppler vs. impedance plethysmography. Pacing Clin Electrophysiol 2000, 23:59.
    • (2000) Pacing Clin Electrophysiol , vol.23 , pp. 59
    • Hayes, D.L.1    Hayes, S.N.2    Hyberger, L.K.3
  • 50
    • 25444523480 scopus 로고    scopus 로고
    • Impedance cardiography as a noninvasive technique for atrioventricular interval optimization in cardiac resynchronization therapy
    • Braun MU, Schnabel A, Rauwolf T, et al.: Impedance cardiography as a noninvasive technique for atrioventricular interval optimization in cardiac resynchronization therapy. J Interv Card Electrophysiol 2005, 13:223-229.
    • (2005) J Interv Card Electrophysiol , vol.13 , pp. 223-229
    • Braun, M.U.1    Schnabel, A.2    Rauwolf, T.3
  • 51
    • 14744296144 scopus 로고    scopus 로고
    • Noninvasive hemodynamic profiles in hypertensive subjects
    • Abdelhammed AI, Smith RD, Levy P, et al.: Noninvasive hemodynamic profiles in hypertensive subjects. Am J Hypertens 2005, 18(2 Part 2):51S-59S.
    • (2005) Am J Hypertens , vol.18 , Issue.2 PART 2
    • Abdelhammed, A.I.1    Smith, R.D.2    Levy, P.3
  • 52
    • 0036107152 scopus 로고    scopus 로고
    • Resistant hypertension: Comparing hemodynamic management to specialist care
    • Taler SJ, Textor SC, Augustine JE: Resistant hypertension: comparing hemodynamic management to specialist care. Hypertension 2002, 39:982-988.
    • (2002) Hypertension , vol.39 , pp. 982-988
    • Taler, S.J.1    Textor, S.C.2    Augustine, J.E.3
  • 53
    • 33645802371 scopus 로고    scopus 로고
    • Value of noninvasive hemodynamics to achieve blood pressure control in hypertensive subjects
    • for the Consideration of Noninvasive Hemodynamic Monitoring to Target Reduction of Blood Pressure Levels Study Group
    • Smith RD, Levy P, Ferrario CM, for the Consideration of Noninvasive Hemodynamic Monitoring to Target Reduction of Blood Pressure Levels Study Group: Value of noninvasive hemodynamics to achieve blood pressure control in hypertensive subjects. Hypertension 2006, 47:769-775. Controlled trial of use of ICG to adjust hypertensive medications shows improved blood pressure control. However, it does not answer the question as to whether the benefit is because of better medications used or because of personalized drug selection.
    • (2006) Hypertension , vol.47 , pp. 769-775
    • Smith, R.D.1    Levy, P.2    Ferrario, C.M.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.