메뉴 건너뛰기




Volumn 22, Issue 8, 1996, Pages 766-771

The influence of weight on stroke volume determination by means of impedance cardiography in cardiac surgery patients

Author keywords

Body weight; Impedance cardiography; Miscalculation; Stroke volume

Indexed keywords

ACCURACY; ADULT; AGED; ARTICLE; BODY WEIGHT; CLINICAL ARTICLE; CORONARY ARTERY BYPASS SURGERY; CORRELATION FUNCTION; FEMALE; HEART STROKE VOLUME; HUMAN; IMPEDANCE CARDIOGRAPHY; INTERMETHOD COMPARISON; MALE; OBESITY; THERMODILUTION;

EID: 0029907058     PISSN: 03424642     EISSN: None     Source Type: Journal    
DOI: 10.1007/BF01709519     Document Type: Article
Times cited : (20)

References (28)
  • 2
    • 0020422439 scopus 로고
    • Continuous noninvasive monitoring of left ventricular function during exercise by thoracic impedance cardiography-automated deviation of systolic time intervals
    • Sheps DS, Petrovick ML, Kizakcvich PN, Wolfe C. Craige E (1982) Continuous noninvasive monitoring of left ventricular function during exercise by thoracic impedance cardiography-automated deviation of systolic time intervals. Am Heart J 103:519-524
    • (1982) Am Heart J , vol.103 , pp. 519-524
    • Sheps, D.S.1    Petrovick, M.L.2    Kizakcvich, P.N.3    Wolfe, C.4    Craige, E.5
  • 5
    • 0022872571 scopus 로고
    • Comparison of transthoracic electrical impedance and thermodilution methods for measuring cardiac output
    • Donovan KD, Geoffrey J, Dobb GJ, Woods WPD (1986) Comparison of transthoracic electrical impedance and thermodilution methods for measuring cardiac output. Crit Care Med 14: 1038-1044
    • (1986) Crit Care Med , vol.14 , pp. 1038-1044
    • Donovan, K.D.1    Geoffrey, J.2    Dobb, G.J.3    Woods, W.P.D.4
  • 6
    • 0022979027 scopus 로고
    • Continuous noninvasive real time monitoring of stroke volume and cardiac output by thoracic electrical bioimpedance
    • Bernstein DP (1986) Continuous noninvasive real time monitoring of stroke volume and cardiac output by thoracic electrical bioimpedance. Crit Care Med 14: 898-901
    • (1986) Crit Care Med , vol.14 , pp. 898-901
    • Bernstein, D.P.1
  • 7
    • 0027458319 scopus 로고
    • Comparison of thoracical electrical bioimpedance and thermodilution for measurement of cardiac index in patients with severe sepsis
    • Young JD, McQuillan P (1993) Comparison of thoracical electrical bioimpedance and thermodilution for measurement of cardiac index in patients with severe sepsis. Br J Anaesth 70: 58-62
    • (1993) Br J Anaesth , vol.70 , pp. 58-62
    • Young, J.D.1    McQuillan, P.2
  • 8
    • 0025786660 scopus 로고
    • Bioimpedance versus thermodilution cardiac output measurement: The Bomed NCCOM3 after coronary bypass surgery
    • Thomas AN, Ryan J, Doran BRH, Pollard BJ (1991) Bioimpedance versus thermodilution cardiac output measurement: the Bomed NCCOM3 after coronary bypass surgery. Intensive Care Med 17: 383-386
    • (1991) Intensive Care Med , vol.17 , pp. 383-386
    • Thomas, A.N.1    Ryan, J.2    Doran, B.R.H.3    Pollard, B.J.4
  • 11
    • 84981642933 scopus 로고
    • Impedance cardiography as a noninvasive method of monitoring cardiac function and other parameters of the cardiovascular system
    • Kubicek WG, Patterson RP, Wisoe DA (1970) Impedance cardiography as a noninvasive method of monitoring cardiac function and other parameters of the cardiovascular system. Ann NY Acad Sci 170: 724
    • (1970) Ann NY Acad Sci , vol.170 , pp. 724
    • Kubicek, W.G.1    Patterson, R.P.2    Wisoe, D.A.3
  • 12
    • 0001952126 scopus 로고
    • Stroke volume equation with a linear base impedance model and its accuracy as compared to thermodilution and magnetic flowmeter techniques in humans and animals
    • Zadar, Yugoslavia
    • Sramek BB, Rose DM, Miyamoto A (1983) Stroke volume equation with a linear base impedance model and its accuracy as compared to thermodilution and magnetic flowmeter techniques in humans and animals. In: Proceedings of the Sixth International Conference on Electr Bioimp, Zadar, Yugoslavia, p 38
    • (1983) Proceedings of the Sixth International Conference on Electr Bioimp , pp. 38
    • Sramek, B.B.1    Rose, D.M.2    Miyamoto, A.3
  • 13
    • 0022980897 scopus 로고
    • A new stroke volume equation for thoracic electrical bioimpedance: Theory and rationale
    • Bernstein DP (1986) A new stroke volume equation for thoracic electrical bioimpedance: theory and rationale. Crit Care Med 14: 904-909
    • (1986) Crit Care Med , vol.14 , pp. 904-909
    • Bernstein, D.P.1
  • 14
    • 0024323057 scopus 로고
    • Comparison of two impedance cardiographic techniques for measuring cardiac output in critically ill patients
    • Gotshall RW, Wood VC, Miles DS (1990) Comparison of two impedance cardiographic techniques for measuring cardiac output in critically ill patients. Crit Care Med 17: 806-811
    • (1990) Crit Care Med , vol.17 , pp. 806-811
    • Gotshall, R.W.1    Wood, V.C.2    Miles, D.S.3
  • 15
    • 0023864184 scopus 로고
    • Noninvasive assessment of cardiac output by impedance cardiography: Disagreement between two equations to estimate stroke volume
    • DeMey C, Enterling D (1988) Noninvasive assessment of cardiac output by impedance cardiography: disagreement between two equations to estimate stroke volume. Aviat Space Environ Med 59: 57-62
    • (1988) Aviat Space Environ Med , vol.59 , pp. 57-62
    • DeMey, C.1    Enterling, D.2
  • 16
    • 0017756202 scopus 로고
    • Evaluation of impedance cardiography during anaesthesia in extremely obese patients
    • Rasmussen JP, Eriksen J, Andersen J (1970) Evaluation of impedance cardiography during anaesthesia in extremely obese patients. Acta Anaesth Scand 21: 342-345
    • (1970) Acta Anaesth Scand , vol.21 , pp. 342-345
    • Rasmussen, J.P.1    Eriksen, J.2    Andersen, J.3
  • 17
    • 0029023737 scopus 로고
    • Comparison between spot and band electrodes and between two equations for calculation of stroke volume by means of impedance cardiography
    • Woltjer HH, van der Meer BJM, Bogaard HJ, de Vries PMJM (1995) Comparison between spot and band electrodes and between two equations for calculation of stroke volume by means of impedance cardiography. Med Biol Eng Comput 33: 330-334
    • (1995) Med Biol Eng Comput , vol.33 , pp. 330-334
    • Woltjer, H.H.1    Van Der Meer, B.J.M.2    Bogaard, H.J.3    De Vries, P.M.J.M.4
  • 20
    • 0026679307 scopus 로고
    • A new ensemble averaging technique in impedance cardiography for estimation of stroke volume during treadmill exercise
    • Kim DW, Song CG, Lee MH (1992) A new ensemble averaging technique in impedance cardiography for estimation of stroke volume during treadmill exercise. Front Med Biol Eng 4: 179-188
    • (1992) Front Med Biol Eng , vol.4 , pp. 179-188
    • Kim, D.W.1    Song, C.G.2    Lee, M.H.3
  • 21
    • 0019796990 scopus 로고
    • Influence of respiration on stroke volume determined by impedunee cardiography
    • Doerr BM, Miles D, Frey BMA (1981) Influence of respiration on stroke volume determined by impedunee cardiography. Aviat Space Environ Med 52: 394-398
    • (1981) Aviat Space Environ Med , vol.52 , pp. 394-398
    • Doerr, B.M.1    Miles, D.2    Frey, B.M.A.3
  • 22
    • 0019596368 scopus 로고
    • Variability of thoracic impedance cardiograms in man
    • Souza WM, Panerai RB (1981) Variability of thoracic impedance cardiograms in man. Med Biol Eng Comput 19: 411-415
    • (1981) Med Biol Eng Comput , vol.19 , pp. 411-415
    • Souza, W.M.1    Panerai, R.B.2
  • 23
    • 0015629580 scopus 로고
    • The specific resistance of blood at body temperature
    • Geddes LA, Sadler C (1973) The specific resistance of blood at body temperature. Med Biol Eng Comput 11: 336-339
    • (1973) Med Biol Eng Comput , vol.11 , pp. 336-339
    • Geddes, L.A.1    Sadler, C.2
  • 24
    • 0016482620 scopus 로고
    • The importance of blood resistivity in the mesurement of cardiac output by the thoracic impedance method
    • Hill DW, Thompson FD (1975) The importance of blood resistivity in the mesurement of cardiac output by the thoracic impedance method. Med Biol Eng Comput 3: 187-190
    • (1975) Med Biol Eng Comput , vol.3 , pp. 187-190
    • Hill, D.W.1    Thompson, F.D.2
  • 25
    • 84908219488 scopus 로고
    • Statistical methods for assessing agreement between two methods of clinical measurement
    • Bland JM, Altman DG (1986) Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1: 307-310
    • (1986) Lancet , vol.1 , pp. 307-310
    • Bland, J.M.1    Altman, D.G.2
  • 26
  • 27
    • 0019914587 scopus 로고
    • Evaluation of the parallel conductor theory for measuring human limb blood flow by electrical admittance plethysmography
    • Shimazu H, Yamakoshi K, Togawa T, Gukuoka M, Ito H (1982) Evaluation of the parallel conductor theory for measuring human limb blood flow by electrical admittance plethysmography. IEEE Trans Biomed Eng 29: 1-7
    • (1982) IEEE Trans Biomed Eng , vol.29 , pp. 1-7
    • Shimazu, H.1    Yamakoshi, K.2    Togawa, T.3    Gukuoka, M.4    Ito, H.5
  • 28
    • 84943729998 scopus 로고
    • Investigation of the parallel conductor model of impedance cardiography by means of exchange transfusion with stroma free haemoglobin solution in the dog
    • Visser KR, Lamberts R, Zijlstra WG (1987) Investigation of the parallel conductor model of impedance cardiography by means of exchange transfusion with stroma free haemoglobin solution in the dog. Cardiovasc Res 21: 637-645
    • (1987) Cardiovasc Res , vol.21 , pp. 637-645
    • Visser, K.R.1    Lamberts, R.2    Zijlstra, W.G.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.