1
-
-
1842377447
-
Improved survival with preoperative radiotherapy in resectable rectal cancer
-
Swedish Rectal Cancer Trial
-
Swedish Rectal Cancer Trial, " Improved survival with preoperative radiotherapy in resectable rectal cancer., " N. Engl. J. Med. 336, 980-987 (1997).
-
(1997)
N. Engl. J. Med.
, vol.336
, pp. 980-987
-
-
-
2
-
-
0035975394
-
Preoperative radiotherapy combined with total mesorectal excision for resectable rectal cancer
-
E. Kapiteijn, " Preoperative radiotherapy combined with total mesorectal excision for resectable rectal cancer., " N. Engl. J. Med. 345, 638-646 (2001).
-
(2001)
N. Engl. J. Med.
, vol.345
, pp. 638-646
-
-
Kapiteijn, E.1
-
3
-
-
6044226542
-
Preoperative versus Postoperative Chemoradiotherapy for Rectal Cancer
-
R. Sauer, " Preoperative versus Postoperative Chemoradiotherapy for Rectal Cancer., " N. Engl. J. Med. 351, 1731-1740 (2004).
-
(2004)
N. Engl. J. Med.
, vol.351
, pp. 1731-1740
-
-
Sauer, R.1
-
4
-
-
0034706001
-
Preoperative Radiotherapy for Resectable Rectal Cancer: A Meta-analysis
-
C. Camm̀, M. Giunta, F. Fiorica, L. Pagliaro, A. Craxì, and M. Cottone, " Preoperative Radiotherapy for Resectable Rectal Cancer: A Meta-analysis., " J. Am. Med. Assoc. 284, 1008-1015 (2000).
-
(2000)
J. Am. Med. Assoc.
, vol.284
, pp. 1008-1015
-
-
Camm̀, C.1
Giunta, M.2
Fiorica, F.3
Pagliaro, L.4
Craxì, A.5
Cottone, M.6
-
5
-
-
0035922657
-
Adjuvant radiotherapy for rectal cancer: A systematic overview of 8507 patients from 22 randomized trials
-
Colorectal Cancer Collaborative Group, "
-
Colorectal Cancer Collaborative Group, " Adjuvant radiotherapy for rectal cancer: a systematic overview of 8507 patients from 22 randomized trials., " Lancet 358, 1291-1304 (2001).
-
(2001)
Lancet
, vol.358
, pp. 1291-1304
-
-
-
6
-
-
2942750356
-
Improved sphincter preservation with high dose preoperative radiotherapy: The Lyon R96-02 randomized trial
-
J. P. Gerard, " Improved sphincter preservation with high dose preoperative radiotherapy: The Lyon R96-02 randomized trial., " J. Clin. Oncol. 22, 2404-2409 (2004).
-
(2004)
J. Clin. Oncol.
, vol.22
, pp. 2404-2409
-
-
Gerard, J.P.1
-
7
-
-
25144448513
-
High-dose-rate endorectal brachytherapy in the treatment of locally advanced rectal carcinoma: Technical aspects
-
T. Vuong, S. Devic, B. Moftah, M. Evans, and E. B. Podgorsak, " High-dose-rate endorectal brachytherapy in the treatment of locally advanced rectal carcinoma: Technical aspects., " Brachytherapy 4, 230-235 (2005).
-
(2005)
Brachytherapy
, vol.4
, pp. 230-235
-
-
Vuong, T.1
Devic, S.2
Moftah, B.3
Evans, M.4
Podgorsak, E.B.5
-
8
-
-
18744391935
-
Conformal preoperative endorectal brachytherapy treatment for locally advanced rectal cancer
-
T. Vuong, P. J. Belliveau, R. P. Michel, B. A. Moftah, J. Parent, J. L. Trudel, C. Reinhold, and L. Souhami, " Conformal preoperative endorectal brachytherapy treatment for locally advanced rectal cancer., " Dis. Colon Rectum 45, 1486-1495 (2002).
-
(2002)
Dis. Colon Rectum
, vol.45
, pp. 1486-1495
-
-
Vuong, T.1
Belliveau, P.J.2
Michel, R.P.3
Moftah, B.A.4
Parent, J.5
Trudel, J.L.6
Reinhold, C.7
Souhami, L.8
-
9
-
-
85026339264
-
Advantages of inflatable multichannel endorectal applicator in the neo-adjuvant treatment of patients with locally advanced rectal cancer with HDR brachytherapy
-
S. Devic, T. Vuong, and B. Moftah, " Advantages of inflatable multichannel endorectal applicator in the neo-adjuvant treatment of patients with locally advanced rectal cancer with HDR brachytherapy., " J. Appl. Clin. Med. Phys. 6, 44-49 (2005).
-
(2005)
J. Appl. Clin. Med. Phys.
, vol.6
, pp. 44-49
-
-
Devic, S.1
Vuong, T.2
Moftah, B.3
-
10
-
-
0028919251
-
Dosimetry of interstitial brachytherapy sources: Recommendations of the AAPM RadiationTherapy Committee Task Group No. 43
-
R. Nath, L. L. Anderson, G. Luxton, K. A. Weaver, J. F. Williamson, and A. S. Meigooni, " Dosimetry of interstitial brachytherapy sources: Recommendations of the AAPM RadiationTherapy Committee Task Group No. 43., " Med. Phys. 22, 209-234 (1995).
-
(1995)
Med. Phys.
, vol.22
, pp. 209-234
-
-
Nath, R.1
Anderson, L.L.2
Luxton, G.3
Weaver, K.A.4
Williamson, J.F.5
Meigooni, A.S.6
-
12
-
-
0031739032
-
Monte Carlo-aided dosimetry of a new high dose-rate brachytherapy source
-
G. M. Daskalov, E. Löffler, and J. F. Williamson, " Monte Carlo-aided dosimetry of a new high dose-rate brachytherapy source., " Med. Phys. 25, 2200-2208 (1998).
-
(1998)
Med. Phys.
, vol.25
, pp. 2200-2208
-
-
Daskalov, G.M.1
Löffler, E.2
Williamson, J.F.3
-
13
-
-
84864166247
-
-
a web-based database maintained by the National Nuclear Data Center, Brookhaven National Laboratory (Upton, NY)
-
NuDat 2.0 National Nuclear Data Center 2004 Nuclear data from NuDat, a web-based database maintained by the National Nuclear Data Center, Brookhaven National Laboratory (Upton, NY) http://www.nndc.bnl.gov/nudat2.
-
NuDat 2.0 National Nuclear Data Center 2004 Nuclear Data from NuDat
-
-
-
14
-
-
0034806529
-
Beta versus gamma dosimetry close to Ir-192 brachytherapy sources
-
D. Baltas, P. Karaiskos, P. Papagiannis, L. Sakelliou, E. Loeffler, and N. Zamboglou, " Beta versus gamma dosimetry close to Ir-192 brachytherapy sources., " Med. Phys. 28, 1875-1882 (2001).
-
(2001)
Med. Phys.
, vol.28
, pp. 1875-1882
-
-
Baltas, D.1
Karaiskos, P.2
Papagiannis, P.3
Sakelliou, L.4
Loeffler, E.5
Zamboglou, N.6
-
15
-
-
0036703411
-
Dose characterization in the near-source region for two high dose rate brachytherapy sources
-
R. Wang and X. A. Li, " Dose characterization in the near-source region for two high dose rate brachytherapy sources., " Med. Phys. 29, 1678-1686 (2002).
-
(2002)
Med. Phys.
, vol.29
, pp. 1678-1686
-
-
Wang, R.1
Li, X.A.2
-
16
-
-
79960251481
-
-
GEANT4 Collaboration
-
GEANT4 Collaboration," Physics Reference Manual., " (online), available at http://geant4.web.cern.ch/geant4/.
-
Physics Reference Manual
-
-
-
17
-
-
14644405544
-
Accuracy of the photon and electron physics in GEANT4 for radiotherapy applications
-
E. Poon and F. Verhaegen, " Accuracy of the photon and electron physics in GEANT4 for radiotherapy applications., " Med. Phys. 32, 1696-1711 (2005).
-
(2005)
Med. Phys.
, vol.32
, pp. 1696-1711
-
-
Poon, E.1
Verhaegen, F.2
-
18
-
-
0004007304
-
-
D. E. Cullen, J. H. Hubbell, and L. Kissel, " EPDL97: The Evaluated Photon Data Library, '97 Version., " Lawrence Livermore National Laboratory, UCRL-50400, Vol. 6, Rev. 5, Livermore, (1997).
-
(1997)
EPDL97: The Evaluated Photon Data Library, '97 Version
, vol.6
-
-
Cullen, D.E.1
Hubbell, J.H.2
Kissel, L.3
-
19
-
-
0003462162
-
-
UCRL-50400, Vol.
-
S. T. Perkins, D. E. Cullen, M. H. Chen, J. H. Hubbell, J. Rathkopf, and J. Scofield, " Tables and graphs of atomic subshell and relaxation data derived from the LLNL evaluated Atomic Data Library (EADL), Z=1-100., " Lawrence Livermore National Laboratory Report UCRL-50400, Vol. 30, Livermore, 1991.
-
(1991)
Tables and Graphs of Atomic Subshell and Relaxation Data Derived from the LLNL Evaluated Atomic Data Library (EADL), Z=1-100
, vol.30
-
-
Perkins, S.T.1
Cullen, D.E.2
Chen, M.H.3
Hubbell, J.H.4
Rathkopf, J.5
Scofield, J.6
-
21
-
-
0033461145
-
Radial dose distribution, dose to water and dose rate constant for monoenergetic photon point sources from 10 keV to 2 MeV: EGS4 Monte Carlo model calculation
-
G. Luxton and G. Jozsef, " Radial dose distribution, dose to water and dose rate constant for monoenergetic photon point sources from 10 keV to 2 MeV: EGS4 Monte Carlo model calculation., Med. Phys. 26, 2531-2538 (1999).
-
(1999)
Med. Phys.
, vol.26
, pp. 2531-2538
-
-
Luxton, G.1
Jozsef, G.2
-
23
-
-
0023514509
-
Monte Carlo evaluation of kerma at a point for photon transport problems
-
J. F. Williamson, " Monte Carlo evaluation of kerma at a point for photon transport problems., " Med. Phys. 14, 567-576 (1987).
-
(1987)
Med. Phys.
, vol.14
, pp. 567-576
-
-
Williamson, J.F.1
-
24
-
-
0038715538
-
Incorporation of a combinatorial geometry package and improved scoring capabilities in the EGSnrc Monte Carlo code system
-
M. Fragoso, J. Seco, A. E. Nahum, and F. Verhaegen, " Incorporation of a combinatorial geometry package and improved scoring capabilities in the EGSnrc Monte Carlo code system., " Med. Phys. 30, 1076-1085 (2003).
-
(2003)
Med. Phys.
, vol.30
, pp. 1076-1085
-
-
Fragoso, M.1
Seco, J.2
Nahum, A.E.3
Verhaegen, F.4
-
25
-
-
0037241039
-
IVBTMC, a Monte Carlo dose calculation tool for intravascular brachytherapy
-
O. Chibani and X. A. Li, " IVBTMC, A Monte Carlo dose calculation tool for intravascular brachytherapy., " Med. Phys. 30, 44-51 (2003).
-
(2003)
Med. Phys.
, vol.30
, pp. 44-51
-
-
Chibani, O.1
Li, X.A.2
-
26
-
-
33644999267
-
MCPI: A sub-minute Monte Carlo dose calculation engine for prostate implants
-
O. Chibani and J. F. Williamson, " MCPI: A sub-minute Monte Carlo dose calculation engine for prostate implants., " Med. Phys. 32, 3688-3698 (2005).
-
(2005)
Med. Phys.
, vol.32
, pp. 3688-3698
-
-
Chibani, O.1
Williamson, J.F.2
-
27
-
-
33644624376
-
Impact of interseed attenuation and tissue composition for permanent prostate implants
-
J. F. Carrier, L. Beaulieu, F. Therriault-Proulx, and R. Roy, " Impact of interseed attenuation and tissue composition for permanent prostate implants., " Med. Phys. 33, 595-604 (2006).
-
(2006)
Med. Phys.
, vol.33
, pp. 595-604
-
-
Carrier, J.F.1
Beaulieu, L.2
Therriault-Proulx, F.3
Roy, R.4
-
28
-
-
27644471150
-
Weak energy dependence of EBT GAFCHROMIC film dose response in the 50 kVp - 10 MVp x-ray range
-
M. J. Butson, T. Cheung, and P. K. N. Yu, " Weak energy dependence of EBT GAFCHROMIC film dose response in the 50 kVp - 10 MVp x-ray range., " Appl. Radiat. Isot. 64, 60-62 (2006).
-
(2006)
Appl. Radiat. Isot.
, vol.64
, pp. 60-62
-
-
Butson, M.J.1
Cheung, T.2
Yu, P.K.N.3
-
29
-
-
22544440841
-
Precise radiochromic film dosimetry using a flat-bed document scanner
-
S. Devic, J. Seuntjens, E. Sham, E. B. Podgorsak, C. R. Schmidtlein, A. S. Kirov, and C. G. Soares, " Precise radiochromic film dosimetry using a flat-bed document scanner., " Med. Phys. 32, 2245-2253 (2005).
-
(2005)
Med. Phys.
, vol.32
, pp. 2245-2253
-
-
Devic, S.1
Seuntjens, J.2
Sham, E.3
Podgorsak, E.B.4
Schmidtlein, C.R.5
Kirov, A.S.6
Soares, C.G.7
-
30
-
-
33845298833
-
Sensitivity of document scanners used for radiochromic film dosimetry
-
Y. Wang, D. Lewis, E. Poon, F. Verhaegen, E. Podgorsak, and S. Devic, " Sensitivity of document scanners used for radiochromic film dosimetry., " Med. Phys. 33, 2135 (2006).
-
(2006)
Med. Phys.
, vol.33
, pp. 2135
-
-
Wang, Y.1
Lewis, D.2
Poon, E.3
Verhaegen, F.4
Podgorsak, E.5
Devic, S.6
-
31
-
-
0024157010
-
On the choice of phantom material for the dosimetry of Ir192 sources
-
J. A. Meli, A. S. Meigooni, and R. Nath, " On the choice of phantom material for the dosimetry of Ir192 sources., " Int. J. Radiat. Oncol., Biol., Phys. 14, 587-594 (1988).
-
(1988)
Int. J. Radiat. Oncol., Biol., Phys.
, vol.14
, pp. 587-594
-
-
Meli, J.A.1
Meigooni, A.S.2
Nath, R.3
-
32
-
-
0036852599
-
Evaluation and characterization of parallel plate microchamber's functionalities in small beam dosimetry
-
H. R. Lee, M. Pankuch, J. C. Chu, and J. J. Spokas, " Evaluation and characterization of parallel plate microchamber's functionalities in small beam dosimetry., " Med. Phys. 29, 2489-2496 (2002).
-
(2002)
Med. Phys.
, vol.29
, pp. 2489-2496
-
-
Lee, H.R.1
Pankuch, M.2
Chu, J.C.3
Spokas, J.J.4
-
33
-
-
0029944194
-
Measurement and calculation of heterogeneity correction factors for an Ir-192 high dose-rate brachytherapy source behind tungsten alloy and steel shields
-
A. S. Kirov, J. F. Williamson, A. S. Meigooni, and Y. Zhu, " Measurement and calculation of heterogeneity correction factors for an Ir-192 high dose-rate brachytherapy source behind tungsten alloy and steel shields., " Med. Phys. 23, 911-919 (1996).
-
(1996)
Med. Phys.
, vol.23
, pp. 911-919
-
-
Kirov, A.S.1
Williamson, J.F.2
Meigooni, A.S.3
Zhu, Y.4
-
34
-
-
0028158549
-
Dose distributions produced by a shielded vaginal cylinder using a high-activity iridium-192 source
-
F. M. Waterman and D. E. Holcomb, " Dose distributions produced by a shielded vaginal cylinder using a high-activity iridium-192 source., " Med. Phys. 21, 101-106 (1994).
-
(1994)
Med. Phys.
, vol.21
, pp. 101-106
-
-
Waterman, F.M.1
Holcomb, D.E.2
-
35
-
-
1142304255
-
Update of AAPM Task Group No. 43 Report: A revised AAPM protocol for brachytherapy dose calculations
-
M. J. Rivard, B. M. Coursey, L. A. DeWerd, W. F. Hanson, M. S. Huq, G. S. Ibbott, M. G. Mitch, R. Nath, and J. F. Williamson, " Update of AAPM Task Group No. 43 Report: A revised AAPM protocol for brachytherapy dose calculations., " Med. Phys. 31, 633-674 (2004).
-
(2004)
Med. Phys.
, vol.31
, pp. 633-674
-
-
Rivard, M.J.1
Coursey, B.M.2
Dewerd, L.A.3
Hanson, W.F.4
Huq, M.S.5
Ibbott, G.S.6
Mitch, M.G.7
Nath, R.8
Williamson, J.F.9
-
36
-
-
0028320064
-
Activity determination of Ir192 solid sources by ionization chamber measurements using calculated corrections for self-absorption
-
L. Büermann, H. M. Kramer, H. Schrader, and H. J. Selbach, " Activity determination of Ir192 solid sources by ionization chamber measurements using calculated corrections for self-absorption., " Nucl. Instrum. Methods Phys. Res. A 339, 369-376 (1994).
-
(1994)
Nucl. Instrum. Methods Phys. Res. a
, vol.339
, pp. 369-376
-
-
Büermann, L.1
Kramer, H.M.2
Schrader, H.3
Selbach, H.J.4
|