메뉴 건너뛰기




Volumn 32, Issue 12, 2006, Pages 1191-1193

Vickers Hardness Investigation of Work-Hardening in Used NiTi Rotary Instruments

Author keywords

[No Author keywords available]

Indexed keywords

DENTAL ALLOY; NICKEL; TITANIUM; TITANIUM NICKELIDE;

EID: 33845284872     PISSN: 00992399     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.joen.2006.07.007     Document Type: Article
Times cited : (23)

References (22)
  • 1
    • 0033147312 scopus 로고    scopus 로고
    • Dynamic and cyclic fatigue of engine-driven rotary nickel-titanium endodontic instruments
    • Haikel Y., Serfaty R., Bateman G., Senger B., and Allemann C. Dynamic and cyclic fatigue of engine-driven rotary nickel-titanium endodontic instruments. J Endod 25 (1999) 434-440
    • (1999) J Endod , vol.25 , pp. 434-440
    • Haikel, Y.1    Serfaty, R.2    Bateman, G.3    Senger, B.4    Allemann, C.5
  • 2
    • 0036691839 scopus 로고    scopus 로고
    • Behaviour of Hero NiTi instruments used by an experienced operator under access limitations
    • Yared G.M. Behaviour of Hero NiTi instruments used by an experienced operator under access limitations. Aust Endod J 28 (2002) 64-67
    • (2002) Aust Endod J , vol.28 , pp. 64-67
    • Yared, G.M.1
  • 3
    • 0036597338 scopus 로고    scopus 로고
    • Cyclic fatigue of endodontic nickel titanium rotary instruments: static and dynamic tests
    • Li U.M., Lee B.S., Shih C.T., Lan W.H., and Lin C.P. Cyclic fatigue of endodontic nickel titanium rotary instruments: static and dynamic tests. J Endod 28 (2002) 448-451
    • (2002) J Endod , vol.28 , pp. 448-451
    • Li, U.M.1    Lee, B.S.2    Shih, C.T.3    Lan, W.H.4    Lin, C.P.5
  • 4
    • 0036632661 scopus 로고    scopus 로고
    • The effect of preflaring on the rates of separation for 0.04 taper nickel titanium rotary instruments
    • Roland D.D., Andelin W.E., Browning D.F., Hsu G.H., and Torabinejad M. The effect of preflaring on the rates of separation for 0.04 taper nickel titanium rotary instruments. J Endod 28 (2002) 543-545
    • (2002) J Endod , vol.28 , pp. 543-545
    • Roland, D.D.1    Andelin, W.E.2    Browning, D.F.3    Hsu, G.H.4    Torabinejad, M.5
  • 5
    • 0034208054 scopus 로고    scopus 로고
    • Rationale for the use of low-torque endodontic motors in root canal instrumentation
    • Gambarini G. Rationale for the use of low-torque endodontic motors in root canal instrumentation. Endod Dent Traumatol 16 (2000) 95-100
    • (2000) Endod Dent Traumatol , vol.16 , pp. 95-100
    • Gambarini, G.1
  • 6
    • 0035656334 scopus 로고    scopus 로고
    • Cyclic fatigue of nickel-titanium rotary instruments after clinical use with low- and high-torque endodontic motors
    • Gambarini G. Cyclic fatigue of nickel-titanium rotary instruments after clinical use with low- and high-torque endodontic motors. J Endod 27 (2001) 772-774
    • (2001) J Endod , vol.27 , pp. 772-774
    • Gambarini, G.1
  • 7
    • 2442680167 scopus 로고    scopus 로고
    • K3 Endo, ProTaper, and ProFile systems: breakage and distortion in severely curved roots of molars
    • Ankrum M.T., Hartwell G.R., and Truitt J.E. K3 Endo, ProTaper, and ProFile systems: breakage and distortion in severely curved roots of molars. J Endod 30 (2004) 234-237
    • (2004) J Endod , vol.30 , pp. 234-237
    • Ankrum, M.T.1    Hartwell, G.R.2    Truitt, J.E.3
  • 8
    • 5444247733 scopus 로고    scopus 로고
    • Factors influencing defects of rotary nickel-titanium endodontic instruments after clinical use
    • Parashos P., Gordon I., and Messer H.H. Factors influencing defects of rotary nickel-titanium endodontic instruments after clinical use. J Endod 30 (2004) 722-725
    • (2004) J Endod , vol.30 , pp. 722-725
    • Parashos, P.1    Gordon, I.2    Messer, H.H.3
  • 9
    • 13544259558 scopus 로고    scopus 로고
    • The influence of a manual glide path on the separation rate of NiTi rotary instruments
    • Patino P.V., Biedma B.M., Liebana C.R., Cantatore G., and Bahillo J.G. The influence of a manual glide path on the separation rate of NiTi rotary instruments. J Endod 31 (2005) 114-116
    • (2005) J Endod , vol.31 , pp. 114-116
    • Patino, P.V.1    Biedma, B.M.2    Liebana, C.R.3    Cantatore, G.4    Bahillo, J.G.5
  • 10
    • 0024052338 scopus 로고
    • An initial investigation of the bending and torsional properties of nitinol root canal files
    • Walia H., Brantley W.A., and Gerstein H. An initial investigation of the bending and torsional properties of nitinol root canal files. J Endod 14 (1988) 346-351
    • (1988) J Endod , vol.14 , pp. 346-351
    • Walia, H.1    Brantley, W.A.2    Gerstein, H.3
  • 11
    • 0034231421 scopus 로고    scopus 로고
    • An overview of nickel-titanium alloys used in dentistry
    • Thompson S.A. An overview of nickel-titanium alloys used in dentistry. Int Endod J 33 (2000) 297-310
    • (2000) Int Endod J , vol.33 , pp. 297-310
    • Thompson, S.A.1
  • 12
    • 0035432084 scopus 로고    scopus 로고
    • Influence of structure on nickel-titanium endodontic instruments failure
    • Kuhn G., Tavernier B., and Jordan L. Influence of structure on nickel-titanium endodontic instruments failure. J Endod 27 (2001) 516-520
    • (2001) J Endod , vol.27 , pp. 516-520
    • Kuhn, G.1    Tavernier, B.2    Jordan, L.3
  • 13
    • 0036835867 scopus 로고    scopus 로고
    • Differential scanning calorimetric studies of nickel-titanium rotary endodontic instruments after simulated clinical use
    • Brantley W.A., Svec T.A., Iijima M., Powers J.M., and Grentzer T.H. Differential scanning calorimetric studies of nickel-titanium rotary endodontic instruments after simulated clinical use. J Endod 28 (2002) 774-778
    • (2002) J Endod , vol.28 , pp. 774-778
    • Brantley, W.A.1    Svec, T.A.2    Iijima, M.3    Powers, J.M.4    Grentzer, T.H.5
  • 14
    • 12344257590 scopus 로고    scopus 로고
    • SEM observations of nickel-titanium rotary endodontic instruments that fractured during clinical use
    • Alapati S.B., Brantley W.A., Svec T.A., Powers J.M., Nusstein J.M., and Daehn G.S. SEM observations of nickel-titanium rotary endodontic instruments that fractured during clinical use. J Endod 31 (2005) 40-43
    • (2005) J Endod , vol.31 , pp. 40-43
    • Alapati, S.B.1    Brantley, W.A.2    Svec, T.A.3    Powers, J.M.4    Nusstein, J.M.5    Daehn, G.S.6
  • 18
    • 0035496468 scopus 로고    scopus 로고
    • Mechanical root canal preparation with NiTi rotary instruments: rationale, performance and safety. Status report for the American Journal of Dentistry
    • Bergmans L., Van Cleynenbreugel J., Wevers M., and Lambrechts P. Mechanical root canal preparation with NiTi rotary instruments: rationale, performance and safety. Status report for the American Journal of Dentistry. Am J Dent 14 (2001) 324-333
    • (2001) Am J Dent , vol.14 , pp. 324-333
    • Bergmans, L.1    Van Cleynenbreugel, J.2    Wevers, M.3    Lambrechts, P.4
  • 19
    • 2442680173 scopus 로고    scopus 로고
    • Proposed role of embedded dentin chips for the clinical failure of nickel-titanium rotary instruments
    • Alapati S.B., Brantley W.A., Svec T.A., Powers J.M., Nusstein J.M., and Daehn G.S. Proposed role of embedded dentin chips for the clinical failure of nickel-titanium rotary instruments. J Endod 30 (2004) 339-341
    • (2004) J Endod , vol.30 , pp. 339-341
    • Alapati, S.B.1    Brantley, W.A.2    Svec, T.A.3    Powers, J.M.4    Nusstein, J.M.5    Daehn, G.S.6
  • 20
    • 0032229551 scopus 로고    scopus 로고
    • Hardness and strength of endodontic instruments made from NiTi alloy
    • Brockhurst P., and Hsu E. Hardness and strength of endodontic instruments made from NiTi alloy. Aust Endod J 24 (1998) 115-119
    • (1998) Aust Endod J , vol.24 , pp. 115-119
    • Brockhurst, P.1    Hsu, E.2
  • 21
    • 0030253003 scopus 로고    scopus 로고
    • Enhanced surface hardness by boron implantation in nitinol alloy
    • Lee D.H., Park B., Saxena A., and Serene T.P. Enhanced surface hardness by boron implantation in nitinol alloy. J Endod 22 (1996) 543-546
    • (1996) J Endod , vol.22 , pp. 543-546
    • Lee, D.H.1    Park, B.2    Saxena, A.3    Serene, T.P.4
  • 22
    • 0035458398 scopus 로고    scopus 로고
    • Wear of nickel-titanium endodontic instruments evaluated by scanning electron microscopy: effect of ion implantation
    • Rapisarda E., Bonaccorso A., Tripi T.R., Condorelli G.G., and Torrisi L. Wear of nickel-titanium endodontic instruments evaluated by scanning electron microscopy: effect of ion implantation. J Endod 27 (2001) 588-592
    • (2001) J Endod , vol.27 , pp. 588-592
    • Rapisarda, E.1    Bonaccorso, A.2    Tripi, T.R.3    Condorelli, G.G.4    Torrisi, L.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.