메뉴 건너뛰기




Volumn 17, Issue 11 I, 2006, Pages 1845-1849

Retrieval of trapped Günther Tulip inferior vena cava filters: Snare-over-guide wire loop technique

Author keywords

[No Author keywords available]

Indexed keywords

ADULT; ARTICLE; CASE REPORT; DEVICE; DEVICE REMOVAL; FEMALE; GUIDE WIRE; HUMAN; INTERMETHOD COMPARISON; INTERNAL JUGULAR VEIN; MALE; PRIORITY JOURNAL; SNARE OVER GUIDE WIRE LOOP TECHNIQUE; TECHNIQUE; ULTRASOUND; VENA CAVA FILTER;

EID: 33751272174     PISSN: 10510443     EISSN: None     Source Type: Journal    
DOI: 10.1097/01.RVI.0000241946.40524.85     Document Type: Article
Times cited : (50)

References (12)
  • 1
    • 33751298668 scopus 로고    scopus 로고
    • Bloomington, IN: Cook Inc., Available at: Accessed February 2006
    • Günther Tulip vena cava filter [product overview]. Bloomington, IN: Cook Inc., 2005. Available at: http://www.cookmedical.com/di/datasheetFeature. do?id=1357. Accessed February 2006.
    • (2005) Günther Tulip Vena Cava Filter [Product Overview]
  • 2
    • 0034852141 scopus 로고    scopus 로고
    • Günther Tulip retrievable vena cava filter: Results from the registry of the Canadian Interventional Radiology Association
    • Millward SF, Oliva VL, Bell SD, et al. Günther Tulip retrievable vena cava filter: results from the registry of the Canadian Interventional Radiology Association. J Vasc Interv Radiol 2001; 12:1053-1058.
    • (2001) J Vasc Interv Radiol , vol.12 , pp. 1053-1058
    • Millward, S.F.1    Oliva, V.L.2    Bell, S.D.3
  • 3
    • 29544447179 scopus 로고    scopus 로고
    • Vena cava filters: Continuing the search for an ideal device
    • Millward SF. Vena cava filters: continuing the search for an ideal device. J Vasc Interv Radiol 2005; 16:1423-1425.
    • (2005) J Vasc Interv Radiol , vol.16 , pp. 1423-1425
    • Millward, S.F.1
  • 4
    • 8444232424 scopus 로고    scopus 로고
    • Extended interval for retrieval of Günther Tulip filters
    • Terhaar OA, Lyon SM, Given MF, et al. Extended interval for retrieval of Günther Tulip filters. J Vasc Interv Radiol 2004; 15:1257-1262.
    • (2004) J Vasc Interv Radiol , vol.15 , pp. 1257-1262
    • Terhaar, O.A.1    Lyon, S.M.2    Given, M.F.3
  • 5
    • 14844360318 scopus 로고    scopus 로고
    • Inferior vena cava filter removal after 317-day implantation
    • Binkert CA, Bansal A, Gates J. Inferior vena cava filter removal after 317-day implantation. J Vasc Interv Radiol 2005; 16:395-398.
    • (2005) J Vasc Interv Radiol , vol.16 , pp. 395-398
    • Binkert, C.A.1    Bansal, A.2    Gates, J.3
  • 6
    • 0142121613 scopus 로고    scopus 로고
    • The Günther Tulip retrievable filter: Prolonged temporary filtration by repositioning within the inferior vena cava
    • De Gregorio MA, Gamboa P, Gimeno MJ, et al. The Günther Tulip retrievable filter: prolonged temporary filtration by repositioning within the inferior vena cava. J Vasc Interv Radiol 2003; 14:1259-1265.
    • (2003) J Vasc Interv Radiol , vol.14 , pp. 1259-1265
    • De Gregorio, M.A.1    Gamboa, P.2    Gimeno, M.J.3
  • 7
    • 0027283608 scopus 로고
    • New retrievable percutaneous vena cava filter: Experimental in-vitro and in vivo evaluation
    • Neuerburg J, Günther RW, Rassmussen E. New retrievable percutaneous vena cava filter: experimental in-vitro and in vivo evaluation. Cardiovasc Intervent Radiol 1993; 16:224-229.
    • (1993) Cardiovasc Intervent Radiol , vol.16 , pp. 224-229
    • Neuerburg, J.1    Günther, R.W.2    Rassmussen, E.3
  • 8
    • 29544441896 scopus 로고    scopus 로고
    • A modified technique to minimize filter tilting during deployment of the Günther Tulip filter: In vitro study
    • Lopera JE, Araki JU, Kirsch D, et al. A modified technique to minimize filter tilting during deployment of the Günther Tulip filter: in vitro study. J Vasc Interv Radiol 2005; 16:1539-1544.
    • (2005) J Vasc Interv Radiol , vol.16 , pp. 1539-1544
    • Lopera, J.E.1    Araki, J.U.2    Kirsch, D.3
  • 9
    • 33744733085 scopus 로고    scopus 로고
    • Successful retrieval of a Günther Tulip vena cava filter with the assistance of a curved sheath introducer
    • Yamagami T, Kato T, Nishimura T. Successful retrieval of a Günther Tulip vena cava filter with the assistance of a curved sheath introducer. J Vasc Interv Radiol 2005; 16:1760-1762.
    • (2005) J Vasc Interv Radiol , vol.16 , pp. 1760-1762
    • Yamagami, T.1    Kato, T.2    Nishimura, T.3
  • 10
    • 33745294000 scopus 로고    scopus 로고
    • Difficult retrieval of a retrievable inferior vena cava filter placed in an inverted orientation
    • Kwok PC, Wong WK, Siu KW, et al. Difficult retrieval of a retrievable inferior vena cava filter placed in an inverted orientation. J Vasc Interv Radiol 2006; 17:153-155.
    • (2006) J Vasc Interv Radiol , vol.17 , pp. 153-155
    • Kwok, P.C.1    Wong, W.K.2    Siu, K.W.3
  • 11
    • 33746902417 scopus 로고    scopus 로고
    • Wall-embedded Recovery inferior vena cava filters: Imaging features and technique for removal
    • Stavropoulos SW, Solomon JA, Trerotola SO. Wall-embedded Recovery inferior vena cava filters: imaging features and technique for removal. J Vasc Interv Radiol 2006; 17:379-382.
    • (2006) J Vasc Interv Radiol , vol.17 , pp. 379-382
    • Stavropoulos, S.W.1    Solomon, J.A.2    Trerotola, S.O.3
  • 12
    • 0038165094 scopus 로고    scopus 로고
    • In vitro study of guide wire entrapment in currently available inferior vena cava filters
    • Stavropoulos SW, Itkin M, Trerotola SO. In vitro study of guide wire entrapment in currently available inferior vena cava filters. J Vasc Interv Radiol 2003; 14:905-910.
    • (2003) J Vasc Interv Radiol , vol.14 , pp. 905-910
    • Stavropoulos, S.W.1    Itkin, M.2    Trerotola, S.O.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.