메뉴 건너뛰기




Volumn 26, Issue 7, 1999, Pages 1312-1319

Self-normalizing method to measure the detective quantum efficiency of a wide range of x-ray detectors

Author keywords

Detective quantum efficiency; Digital radiography; DQE measurement method; Noise equivalent quanta; Noise power spectra

Indexed keywords

EFFICIENCY; MEDICAL IMAGING; X RAY APPARATUS; X RAY DETECTORS; X RAY RADIOGRAPHY; X RAYS;

EID: 0032800112     PISSN: 00942405     EISSN: None     Source Type: Journal    
DOI: 10.1118/1.598626     Document Type: Article
Times cited : (59)

References (19)
  • 1
    • 0029145191 scopus 로고
    • Toward consensus on quantitative assessment of medical imaging systems
    • C. E. Metz, R. F. Wagner, K. Doi, D. G. Brown, R. M. Nishikawa, and K. J. Myers, "Toward consensus on quantitative assessment of medical imaging systems," Med. Phys. 22, 1057-1061 (1995).
    • (1995) Med. Phys. , vol.22 , pp. 1057-1061
    • Metz, C.E.1    Wagner, R.F.2    Doi, K.3    Brown, D.G.4    Nishikawa, R.M.5    Myers, K.J.6
  • 3
    • 0042098598 scopus 로고
    • Detective quantum efficiency of photodetectors with some amplifying mechanisms
    • H. J. Zwieg. "Detective quantum efficiency of photodetectors with some amplifying mechanisms," J. Opt. Soc. Am. 55, 525-528 (1965).
    • (1965) J. Opt. Soc. Am. , vol.55 , pp. 525-528
    • Zwieg, H.J.1
  • 4
    • 0015667930 scopus 로고
    • Absorption and noise in x-ray phosphors
    • R. K. Swank, "Absorption and noise in x-ray phosphors," J. Appl. Phys. 44, 4199-4203 (1973).
    • (1973) J. Appl. Phys. , vol.44 , pp. 4199-4203
    • Swank, R.K.1
  • 5
    • 0021075243 scopus 로고
    • Absorption and noise in cesium iodide x-ray image intensifiers
    • J. A. Rowlands and K. W. Taylor, "Absorption and noise in cesium iodide x-ray image intensifiers," Med. Phys. 10, 786-795 (1983).
    • (1983) Med. Phys. , vol.10 , pp. 786-795
    • Rowlands, J.A.1    Taylor, K.W.2
  • 6
    • 0023339134 scopus 로고
    • Detective quantum efficiency of imaging systems with amplifying and scattering mechanisms
    • M. Rabbani and R. Shaw, "Detective quantum efficiency of imaging systems with amplifying and scattering mechanisms," J. Opt. Soc. Am. A 4, 895-901 (1987).
    • (1987) J. Opt. Soc. Am. A , vol.4 , pp. 895-901
    • Rabbani, M.1    Shaw, R.2
  • 7
    • 0021812629 scopus 로고
    • SNR and DQE analysis of broad spectrum x-ray imaging
    • M. Tapiovaara and R. F. Wagner, "SNR and DQE analysis of broad spectrum x-ray imaging," Phys. Med. Biol. 30, 519-529 (1985).
    • (1985) Phys. Med. Biol. , vol.30 , pp. 519-529
    • Tapiovaara, M.1    Wagner, R.F.2
  • 8
    • 0023611229 scopus 로고
    • Imaging performance of a digital storage phosphor system
    • W. Hillen, U. Schiebel, and T. Zaengel, "Imaging performance of a digital storage phosphor system," Med. Phys. 14, 744-751 (1987).
    • (1987) Med. Phys. , vol.14 , pp. 744-751
    • Hillen, W.1    Schiebel, U.2    Zaengel, T.3
  • 10
    • 0031453264 scopus 로고    scopus 로고
    • Digital radiology using active matrix readout of amorphous selenium: Construction and evaluation of a prototype real-time detector
    • W. Zhao, I. Blevis, S. Germann, and J. A. Rowlands, "Digital radiology using active matrix readout of amorphous selenium: Construction and evaluation of a prototype real-time detector," Med. Phys. 24, 1834-1843 (1997).
    • (1997) Med. Phys. , vol.24 , pp. 1834-1843
    • Zhao, W.1    Blevis, I.2    Germann, S.3    Rowlands, J.A.4
  • 11
    • 0025907199 scopus 로고
    • Analysis and correction of imperfections in the image intensifier-TV-digitizer imaging chain
    • J. M. Boone, J. A. Seibert, W. A. Barrett, and E. A. Blood, "Analysis and correction of imperfections in the image intensifier-TV-digitizer imaging chain," Med. Phys. 18, 236-242 (1991).
    • (1991) Med. Phys. , vol.18 , pp. 236-242
    • Boone, J.M.1    Seibert, J.A.2    Barrett, W.A.3    Blood, E.A.4
  • 12
    • 0021253653 scopus 로고
    • Investigation of basic imaging properties in digital radiography. I. Modulation transfer function
    • M. L. Giger and K. Doi, "Investigation of basic imaging properties in digital radiography. I. Modulation transfer function," Med. Phys. 11, 287-295 (1984).
    • (1984) Med. Phys. , vol.11 , pp. 287-295
    • Giger, M.L.1    Doi, K.2
  • 14
    • 0345656965 scopus 로고
    • Imaging performance of a selenium-based detector for high-resolution radiography
    • W. Hillen, S. Rupp, U. Schiebel, and T. Zaengel, "Imaging performance of a selenium-based detector for high-resolution radiography," Proc. SPIE 1090, 296-305 (1989).
    • (1989) Proc. SPIE , vol.1090 , pp. 296-305
    • Hillen, W.1    Rupp, S.2    Schiebel, U.3    Zaengel, T.4
  • 16
    • 0021155080 scopus 로고
    • Messung der modulationsübertragungsfunktion von film-folien-kombinationen mit einem bleiraster
    • D. Hoeschen, W. Mirandé, "Messung der Modulationsübertragungsfunktion von Film-Folien-Kombinationen mit einem Bleiraster," Fortschr. Röntgenstr. 140, 600-604 (1984).
    • (1984) Fortschr. Röntgenstr. , vol.140 , pp. 600-604
    • Hoeschen, D.1    Mirandé, W.2
  • 17
    • 85027231121 scopus 로고    scopus 로고
    • note
    • German standard DIN 6872, Teil 1, Strahlenqualitäten für Messungen in der radiologischen Technik; Patientendurchlassstrahlung ohne Streustrahlenanteil in der Röntgendiagnostik (Radiation qualities to be used for radiological measurements; diagnostic primary x-radiation beyond the patient without scatter), Nov. 1983.
  • 19
    • 0029712073 scopus 로고    scopus 로고
    • Amorphous silicon x-ray image sensor
    • J. Chabbal et al., "Amorphous silicon x-ray image sensor," Proc. SPIE 2708, 499-510 (1996).
    • (1996) Proc. SPIE , vol.2708 , pp. 499-510
    • Chabbal, J.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.