메뉴 건너뛰기




Volumn 6, Issue 5, 2005, Pages 519-522

Prospective assessment of guidelines for determining appropriate depth of endotracheal tube placement in children

Author keywords

Airway; Emergency room; Endotracheal tube; Mechanical ventilation; Pediatric advanced life support; Pediatric critical care

Indexed keywords

ACCURACY; ARTICLE; ARTIFICIAL VENTILATION; CALCULATION; CHILD; DEMOGRAPHY; EMERGENCY WARD; ENDOTRACHEAL TUBE; HUMAN; INFANT; INTENSIVE CARE; MAJOR CLINICAL STUDY; NEWBORN; PEDIATRICS; POSITION; PRACTICE GUIDELINE; PRIORITY JOURNAL; PROSPECTIVE STUDY; RELIABILITY; RESUSCITATION; THORAX RADIOGRAPHY;

EID: 24944591430     PISSN: 15297535     EISSN: None     Source Type: Journal    
DOI: 10.1097/01.PCC.0000165802.32383.9E     Document Type: Article
Times cited : (54)

References (8)
  • 1
    • 17144466194 scopus 로고    scopus 로고
    • Pediatric Advanced Life Support. Circulation 2000; 102(Suppl 1):291-342
    • (2000) Circulation , vol.102 , Issue.SUPPL. 1 , pp. 291-342
  • 2
    • 0141677974 scopus 로고    scopus 로고
    • The intubation depth marker: The confusion of the black line
    • Goel S, Lim SL: The intubation depth marker: The confusion of the black line. Paediatr Anaesth 2003; 13:579-583
    • (2003) Paediatr Anaesth , vol.13 , pp. 579-583
    • Goel, S.1    Lim, S.L.2
  • 3
    • 0036088825 scopus 로고    scopus 로고
    • Estimation of the length of nasotracheal tube to be introduced in children
    • de la Sierra AM, Lopez-Herce JRM, Garcia C, et al: Estimation of the length of nasotracheal tube to be introduced in children. J Pediatr 2002; 40:772-774
    • (2002) J Pediatr , vol.40 , pp. 772-774
    • De La Sierra, A.M.1    Lopez-Herce, J.R.M.2    Garcia, C.3
  • 4
    • 0033788576 scopus 로고    scopus 로고
    • Appropriateness of endotracheal tube size and insertion depth in children undergoing air medical transport
    • Orf J, Thomas SH, Ahmed W, et al: Appropriateness of endotracheal tube size and insertion depth in children undergoing air medical transport. Pediatr Emerg Care 2000; 16: 321-327
    • (2000) Pediatr Emerg Care , vol.16 , pp. 321-327
    • Orf, J.1    Thomas, S.H.2    Ahmed, W.3
  • 5
    • 6544276932 scopus 로고    scopus 로고
    • Estimation of endotracheal tube depth placement in children
    • Robertson CL, Orr R, Allen B, et al: Estimation of endotracheal tube depth placement in children. Crit Care Med 1998; 26(1 Suppl):A58
    • (1998) Crit Care Med , vol.26 , Issue.1 SUPPL.
    • Robertson, C.L.1    Orr, R.2    Allen, B.3
  • 7
    • 0018730907 scopus 로고
    • Orotracheal intubation in the newborn infant: A method for determining depth of tube insertion
    • Tochen ML: Orotracheal intubation in the newborn infant: A method for determining depth of tube insertion. J Pediatr 1979; 95: 1050-1051
    • (1979) J Pediatr , vol.95 , pp. 1050-1051
    • Tochen, M.L.1
  • 8
    • 0020042965 scopus 로고
    • Linear airway dimensions in children: Including those with cleft palate
    • Morgan GR, Steward DJ: Linear airway dimensions in children: Including those with cleft palate. Can Anaesth Soc J 1982; 29:1-8
    • (1982) Can Anaesth Soc J , vol.29 , pp. 1-8
    • Morgan, G.R.1    Steward, D.J.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.