메뉴 건너뛰기




Volumn 2006, Issue , 2006, Pages 3832-3837

Active mechatronic interface for haptic perception studies with functional magnetic resonance imaging: Compatibility and design criteria

Author keywords

[No Author keywords available]

Indexed keywords

ACTUATORS; BIOCOMPATIBILITY; COGNITIVE SYSTEMS; COMPUTER SIMULATION; DEGREES OF FREEDOM (MECHANICS); MAGNETIC RESONANCE IMAGING; MECHATRONICS; STATISTICAL METHODS;

EID: 33750886421     PISSN: 10504729     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/ROBOT.2006.1642288     Document Type: Conference Paper
Times cited : (13)

References (13)
  • 1
    • 0030013529 scopus 로고    scopus 로고
    • The role of magnetic susceptibility in magnetic resonance imaging: MRI magnetic compatibility of the first and second kinds
    • June
    • J. Schenck, "The role of magnetic susceptibility in magnetic resonance imaging: MRI magnetic compatibility of the first and second kinds," Medical Physics, vol. 23, no. 6, pp. 815-850, June 1996.
    • (1996) Medical Physics , vol.23 , Issue.6 , pp. 815-850
    • Schenck, J.1
  • 2
    • 0022352939 scopus 로고
    • Susceptibility artefacts in NMR imaging
    • K. Ludeke, P. Roschmann, and R. Tischler, "Susceptibility artefacts in NMR imaging," Magn Reson Imaging, vol. 3, no. 4, pp. 329-343, 1985.
    • (1985) Magn Reson Imaging , vol.3 , Issue.4 , pp. 329-343
    • Ludeke, K.1    Roschmann, P.2    Tischler, R.3
  • 3
    • 33845607609 scopus 로고    scopus 로고
    • A primer on medical device interactions with magnetic resonance imaging systems
    • Food and D. Administration, http://www.fda.gov/cdrh/ode/primerf6.html, [Online]
    • Food and D. Administration, "A primer on medical device interactions with magnetic resonance imaging systems," U.S. Department of Health and Human Services, http://www.fda.gov/cdrh/ode/primerf6.html, 1997. [Online]. Available: http://www.fda.gov/cdrh/ode/primerf6.html
    • (1997) U.S. Department of Health and Human Services
  • 4
  • 8
    • 19544362414 scopus 로고    scopus 로고
    • Quality assurance in clinical and research echo planar functional MRI
    • B. P. Moonen, CTW, Ed. Springer-Verlag
    • K. Thulborn, "Quality assurance in clinical and research echo planar functional MRI," in Functional MRI, B. P. Moonen, CTW, Ed. Springer-Verlag, 2000.
    • (2000) Functional MRI
    • Thulborn, K.1
  • 12
    • 0030727106 scopus 로고    scopus 로고
    • Parametric analysis of fMRI data analysis using linear system methods
    • M. Cohen, "Parametric analysis of fMRI data analysis using linear system methods," Neuroimage, vol. 6, no. 2, pp. 93-103, 1997.
    • (1997) Neuroimage , vol.6 , Issue.2 , pp. 93-103
    • Cohen, M.1
  • 13
    • 0030175198 scopus 로고    scopus 로고
    • AFNI: Software for analysis and visualization of functional magnetic resonance neuroimages
    • R. Cox, "AFNI: software for analysis and visualization of functional magnetic resonance neuroimages," Comput Biomed Res, vol. 29, no. 3, pp. 162-173, 1996.
    • (1996) Comput Biomed Res , vol.29 , Issue.3 , pp. 162-173
    • Cox, R.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.