메뉴 건너뛰기




Volumn 16, Issue 1, 1998, Pages 87-90

Estimation of the noise in magnitude MR images

Author keywords

Double acquisition; Noise estimation; Rice distribution

Indexed keywords

ARTICLE; DATA ANALYSIS; IMAGE ANALYSIS; NOISE; NUCLEAR MAGNETIC RESONANCE IMAGING; PRIORITY JOURNAL;

EID: 0031983116     PISSN: 0730725X     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0730-725X(97)00199-9     Document Type: Article
Times cited : (239)

References (13)
  • 5
    • 0021948756 scopus 로고
    • Measurement of signal intensities in the presence of noise in MR images
    • Henkelman R.M. Measurement of signal intensities in the presence of noise in MR images. Medical Physics. 12:(2):1985;232-233.
    • (1985) Medical Physics , vol.12 , Issue.2 , pp. 232-233
    • Henkelman, R.M.1
  • 7
    • 0003012335 scopus 로고
    • NEMA standards. Performance standards for clinical magnetic resonance systems
    • R.L. Dixon. Madison, WI: Medical Physics Publishing Corp
    • Sano R.M. NEMA standards. Performance standards for clinical magnetic resonance systems. Dixon R.L. MRI Acceptance Testing and Quality Control - The Role of the Clinical Medical Physicist. 1988;185-189 Medical Physics Publishing Corp, Madison, WI.
    • (1988) MRI Acceptance Testing and Quality Control - The Role of the Clinical Medical Physicist , pp. 185-189
    • Sano, R.M.1
  • 9
    • 0030425801 scopus 로고    scopus 로고
    • Quantification and improvement of the signal-to-noise ratio in a magnetic resonance image acquisition procedure
    • Sijbers J., Scheunders P., Bonnet N., Van Dyck D., Raman E. Quantification and improvement of the signal-to-noise ratio in a magnetic resonance image acquisition procedure. Magn. Reson. Imaging. 14:(10):1996;1157-1163.
    • (1996) Magn. Reson. Imaging , vol.14 , Issue.10 , pp. 1157-1163
    • Sijbers, J.1    Scheunders, P.2    Bonnet, N.3    Van Dyck, D.4    Raman, E.5
  • 10
  • 12
    • 0027453763 scopus 로고
    • The use of power images to perform quantitative analysis on low SNR MR images
    • Miller A.J., Joseph P.M. The use of power images to perform quantitative analysis on low SNR MR images. Magn. Reson. Imaging. 11:1993;1051-1056.
    • (1993) Magn. Reson. Imaging , vol.11 , pp. 1051-1056
    • Miller, A.J.1    Joseph, P.M.2
  • 13
    • 0027317240 scopus 로고
    • An unbiased signal-to-noise ratio measure for magnetic resonance images
    • McGibney G., Smith M.R. An unbiased signal-to-noise ratio measure for magnetic resonance images. Medical Physics. 20:(4):1993;1077-1078.
    • (1993) Medical Physics , vol.20 , Issue.4 , pp. 1077-1078
    • McGibney, G.1    Smith, M.R.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.