메뉴 건너뛰기




Volumn 126, Issue 5, 2006, Pages 748-755

The effect of specimen hemolysis on coagulation test results

Author keywords

Activated partial thromboplastin time; aPTT; Coagulation; Hemolysis; Prothrombin time; PT

Indexed keywords

ARTICLE; BLOOD CLOTTING TEST; BLOOD SAMPLING; CONTROLLED STUDY; HEMOGLOBIN DETERMINATION; HEMOLYSIS; HUMAN; HUMAN TISSUE; LABORATORY DIAGNOSIS; PARTIAL THROMBOPLASTIN TIME; PRIORITY JOURNAL; PROTHROMBIN TIME; ULTRACENTRIFUGATION;

EID: 33750739241     PISSN: 00029173     EISSN: None     Source Type: Journal    
DOI: 10.1309/03FK3378YTRA1FRF     Document Type: Article
Times cited : (61)

References (18)
  • 1
    • 30444433613 scopus 로고    scopus 로고
    • A comparison of glass and plastic blood collection tubes for routine and specialized coagulation assays
    • Kratz A, Stanganelli N, Van Gott E. A comparison of glass and plastic blood collection tubes for routine and specialized coagulation assays. Arch Pathol Lab Med. 2006;130:39-44.
    • (2006) Arch Pathol Lab Med , vol.130 , pp. 39-44
    • Kratz, A.1    Stanganelli, N.2    Van Gott, E.3
  • 2
    • 0017541553 scopus 로고
    • Effects of preanalytical factors on the individual variation of analytes in the blood of healthy human subjects: Consideration of preparation of the subject and the time of venipuncture
    • Statland BE, Winkel P. Effects of preanalytical factors on the individual variation of analytes in the blood of healthy human subjects: consideration of preparation of the subject and the time of venipuncture. CRC Crit Rev Clin Lab Sci. 1977;8:105-144.
    • (1977) CRC Crit Rev Clin Lab Sci , vol.8 , pp. 105-144
    • Statland, B.E.1    Winkel, P.2
  • 4
    • 0035065278 scopus 로고    scopus 로고
    • Effects of blood-collection systems and tubes on hematologic, chemical, and coagulation tests and on plasma hemoglobin
    • letter
    • Almagor M, Lavid-Levy O. Effects of blood-collection systems and tubes on hematologic, chemical, and coagulation tests and on plasma hemoglobin [letter]. Clin Chem. 2001;47:794-795.
    • (2001) Clin Chem , vol.47 , pp. 794-795
    • Almagor, M.1    Lavid-Levy, O.2
  • 5
    • 7044239520 scopus 로고    scopus 로고
    • Effect of specimen collection on routine coagulation assays and D-dimer measurement
    • Lippi G, Guidi GC. Effect of specimen collection on routine coagulation assays and D-dimer measurement. Clin Chem. 2004;50:2150-2152.
    • (2004) Clin Chem , vol.50 , pp. 2150-2152
    • Lippi, G.1    Guidi, G.C.2
  • 6
    • 0035056646 scopus 로고    scopus 로고
    • Preanalytical aspects of routine coagulation measurements
    • letter
    • Horsti J. Preanalytical aspects of routine coagulation measurements [letter]. Scand J Clin Lab Invest. 2001;61:167-168.
    • (2001) Scand J Clin Lab Invest , vol.61 , pp. 167-168
    • Horsti, J.1
  • 7
    • 0034815620 scopus 로고    scopus 로고
    • Reduction of preanalytical errors due to in vitro activation of coagulation
    • Bartels PC, Schoorl M, van Bodegraven AA. Reduction of preanalytical errors due to in vitro activation of coagulation. Clin Lab. 2001;47:449-452.
    • (2001) Clin Lab , vol.47 , pp. 449-452
    • Bartels, P.C.1    Schoorl, M.2    Van Bodegraven, A.A.3
  • 8
    • 0036592849 scopus 로고    scopus 로고
    • Rejection of specimens for prothrombin time and relating pre-analytical factors in blood collection
    • letter
    • Wiwanitkit V. Rejection of specimens for prothrombin time and relating pre-analytical factors in blood collection [letter]. Blood Coagul Fibrinolysis. 2002;13:371-372.
    • (2002) Blood Coagul Fibrinolysis , vol.13 , pp. 371-372
    • Wiwanitkit, V.1
  • 9
    • 84941841395 scopus 로고
    • Haemolysis as an interference factor in clinical chemistry
    • Sonntag G. Haemolysis as an interference factor in clinical chemistry. J Clin Chem Clin Biochem. 1986;24:127-139.
    • (1986) J Clin Chem Clin Biochem , vol.24 , pp. 127-139
    • Sonntag, G.1
  • 10
    • 0033972513 scopus 로고    scopus 로고
    • Hemolyzed specimens: A reason for rejection or a clinical challenge
    • letter
    • Carraro P, Servidio G, Plebani M. Hemolyzed specimens: a reason for rejection or a clinical challenge [letter]? Clin Chem. 2000;46:306-307.
    • (2000) Clin Chem , vol.46 , pp. 306-307
    • Carraro, P.1    Servidio, G.2    Plebani, M.3
  • 11
    • 0017189846 scopus 로고
    • The effects of 0.1% and 1.0% erythrocytes and hemolysis on serum chemistry values
    • Laessig RH, Hassemer DJ, Paskey TA, et al. The effects of 0.1% and 1.0% erythrocytes and hemolysis on serum chemistry values. Am J Clin Pathol. 1976;66:639-644.
    • (1976) Am J Clin Pathol , vol.66 , pp. 639-644
    • Laessig, R.H.1    Hassemer, D.J.2    Paskey, T.A.3
  • 12
    • 0026720420 scopus 로고
    • Effect of in vitro hemolysis on 25 common biochemical tests
    • Yucel D, Dalva K. Effect of in vitro hemolysis on 25 common biochemical tests. Clin Chem. 1992;38:575-577.
    • (1992) Clin Chem , vol.38 , pp. 575-577
    • Yucel, D.1    Dalva, K.2
  • 13
    • 0027960559 scopus 로고
    • Interference with clinical laboratory analyses
    • Kroll MH, Elin RJ. Interference with clinical laboratory analyses. Clin Chem. 1994;40:1996-2005.
    • (1994) Clin Chem , vol.40 , pp. 1996-2005
    • Kroll, M.H.1    Elin, R.J.2
  • 14
    • 0016759701 scopus 로고
    • A spectrophotometric scanning technique for the rapid determination of plasma hemoglobin
    • Blakney GB, Dinwoodie AJ. A spectrophotometric scanning technique for the rapid determination of plasma hemoglobin. Clin Biochem. 1975;8:96-102.
    • (1975) Clin Biochem , vol.8 , pp. 96-102
    • Blakney, G.B.1    Dinwoodie, A.J.2
  • 15
    • 32544458178 scopus 로고    scopus 로고
    • Interference of blood cell lysis of routine coagulation testing
    • Lippi G, Montagnana M, Salvano GL, et al. Interference of blood cell lysis of routine coagulation testing. Arch Pathol Lab Med. 2006;130:181-184.
    • (2006) Arch Pathol Lab Med , vol.130 , pp. 181-184
    • Lippi, G.1    Montagnana, M.2    Salvano, G.L.3
  • 16
    • 0037242909 scopus 로고    scopus 로고
    • Hemolysis in needleless connectors for phlebotomy
    • Sharp K, Mohammad SF. Hemolysis in needleless connectors for phlebotomy. ASAIO J. 2003;49:128-130.
    • (2003) ASAIO J , vol.49 , pp. 128-130
    • Sharp, K.1    Mohammad, S.F.2
  • 17
    • 0017073174 scopus 로고
    • Effects of stroma-free haemoglobin solution on the blood-clotting system in dogs
    • Uszynski L, Schier J, Rudowski W, et al. Effects of stroma-free haemoglobin solution on the blood-clotting system in dogs. Eur Surg Res. 1976;8:204-210.
    • (1976) Eur Surg Res , vol.8 , pp. 204-210
    • Uszynski, L.1    Schier, J.2    Rudowski, W.3
  • 18
    • 0036728110 scopus 로고    scopus 로고
    • Effects of hemoglobin glutamer-250 (bovine) (HBOC-201, Hemopure) on coagulation testing
    • Jahr JS, Lurie F, Gosselin R, et al. Effects of hemoglobin glutamer-250 (bovine) (HBOC-201, Hemopure) on coagulation testing. Am J Ther. 2002;9:431-436.
    • (2002) Am J Ther , vol.9 , pp. 431-436
    • Jahr, J.S.1    Lurie, F.2    Gosselin, R.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.