메뉴 건너뛰기




Volumn 81, Issue 2, 2006, Pages 184-189

Motion and shape change when using an endorectal balloon during prostate radiation therapy

Author keywords

Endorectal balloon; Immobilization; Inter fraction motion; Prostate

Indexed keywords

ARTICLE; BALLOON; CLINICAL ARTICLE; ENDORECTAL BALLOON; HUMAN; MALE; PRIORITY JOURNAL; PROSTATE CANCER; TISSUE DISTRIBUTION;

EID: 33750703684     PISSN: 01678140     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.radonc.2006.10.004     Document Type: Article
Times cited : (14)

References (21)
  • 1
    • 4444270625 scopus 로고    scopus 로고
    • Measurements of intrafraction motion and inter-fraction and inter-imaging rotation of prostate by three-dimensional analysis of daily portal imaging with radiopaque markers
    • Aubry J.-F., Beaulieu L., Girouard L.-M., et al. Measurements of intrafraction motion and inter-fraction and inter-imaging rotation of prostate by three-dimensional analysis of daily portal imaging with radiopaque markers. Int J Radiat Oncol Biol Phys 60 (2004) 30-39
    • (2004) Int J Radiat Oncol Biol Phys , vol.60 , pp. 30-39
    • Aubry, J.-F.1    Beaulieu, L.2    Girouard, L.-M.3
  • 2
    • 4444285372 scopus 로고    scopus 로고
    • On-line aSi portal imaging of implanted ficudial markers for the reduction on inter-fraction error during conformal radiotherapy of prostate carcinoma
    • Chung P.W.M., Haycocks T., Brown T., et al. On-line aSi portal imaging of implanted ficudial markers for the reduction on inter-fraction error during conformal radiotherapy of prostate carcinoma. Int J Radiat Oncol Biol Phys 60 (2004) 329-334
    • (2004) Int J Radiat Oncol Biol Phys , vol.60 , pp. 329-334
    • Chung, P.W.M.1    Haycocks, T.2    Brown, T.3
  • 3
    • 0036804489 scopus 로고    scopus 로고
    • On-line correction of beam portals in the treatment of prostate cancer using an endorectal balloon device
    • Ciernik I.F., Baumert B.G., Egli P., Glanzmann C., and Lutolf U.M. On-line correction of beam portals in the treatment of prostate cancer using an endorectal balloon device. Radiother Oncol 65 (2002) 39-45
    • (2002) Radiother Oncol , vol.65 , pp. 39-45
    • Ciernik, I.F.1    Baumert, B.G.2    Egli, P.3    Glanzmann, C.4    Lutolf, U.M.5
  • 4
    • 0142025618 scopus 로고    scopus 로고
    • Automatic registration of the prostate for computed-tomography-guided radiotherapy
    • Court L.E., and Dong L. Automatic registration of the prostate for computed-tomography-guided radiotherapy. Med Phys 30 (2003) 2750-2757
    • (2003) Med Phys , vol.30 , pp. 2750-2757
    • Court, L.E.1    Dong, L.2
  • 5
    • 17844400938 scopus 로고    scopus 로고
    • An automatic CT-guided adaptive radiation therapy technique by online modification of multileaf collimator leaf positions for prostate cancer
    • Court L.E., Dong L., Lee A.K., et al. An automatic CT-guided adaptive radiation therapy technique by online modification of multileaf collimator leaf positions for prostate cancer. Int J Radiat Oncol Biol Phys 61 (2005) 154-163
    • (2005) Int J Radiat Oncol Biol Phys , vol.61 , pp. 154-163
    • Court, L.E.1    Dong, L.2    Lee, A.K.3
  • 6
    • 2442551959 scopus 로고    scopus 로고
    • Evaluation of a contour-alignment technique for CT-guided prostate radiotherapy: an intra- and interobserver study
    • Court L.E., Dong L., Taylor N., et al. Evaluation of a contour-alignment technique for CT-guided prostate radiotherapy: an intra- and interobserver study. Int J Radiat Oncol Biol Phys 59 (2004) 412-418
    • (2004) Int J Radiat Oncol Biol Phys , vol.59 , pp. 412-418
    • Court, L.E.1    Dong, L.2    Taylor, N.3
  • 7
    • 0038377171 scopus 로고    scopus 로고
    • Evaluation of mechanical precision and alignment uncertainties for an integrated CT/LINAC system
    • Court L.E., Rosen I., Mohan R., and Dong L. Evaluation of mechanical precision and alignment uncertainties for an integrated CT/LINAC system. Med Phys 30 (2003) 1198-1210
    • (2003) Med Phys , vol.30 , pp. 1198-1210
    • Court, L.E.1    Rosen, I.2    Mohan, R.3    Dong, L.4
  • 8
    • 0035576802 scopus 로고    scopus 로고
    • A practical method to achieve prostate gland immobilization and target verification for daily treatment
    • D'Amico A.V., Manola J., Loffredo M., et al. A practical method to achieve prostate gland immobilization and target verification for daily treatment. Int J Radiat Oncol Biol Phys 51 (2001) 1431-1436
    • (2001) Int J Radiat Oncol Biol Phys , vol.51 , pp. 1431-1436
    • D'Amico, A.V.1    Manola, J.2    Loffredo, M.3
  • 9
    • 0037966410 scopus 로고    scopus 로고
    • Clinical feasibility study for the use of implanted gold seeds in the prostate as reliable positioning markers during megavoltage irradiation
    • Dehnad H., Nederveen A.J., van der Heide U.A., et al. Clinical feasibility study for the use of implanted gold seeds in the prostate as reliable positioning markers during megavoltage irradiation. Radiother Oncol 67 (2003) 295-302
    • (2003) Radiother Oncol , vol.67 , pp. 295-302
    • Dehnad, H.1    Nederveen, A.J.2    van der Heide, U.A.3
  • 10
    • 0034192299 scopus 로고    scopus 로고
    • 3D conformal radiation therapy (3DCRT) for high grade prostate cancer: a multi-institutional review
    • Fiveash J.B., Hanks G., Roach M., et al. 3D conformal radiation therapy (3DCRT) for high grade prostate cancer: a multi-institutional review. Int J Radiat Oncol Biol Phys 47 (2000) 335-342
    • (2000) Int J Radiat Oncol Biol Phys , vol.47 , pp. 335-342
    • Fiveash, J.B.1    Hanks, G.2    Roach, M.3
  • 12
    • 14744296853 scopus 로고    scopus 로고
    • Strategies to reduce the systematic error due to tumor and rectum motion in radiotherapy of prostate cancer
    • Hoogeman M.S., van Herk M., de Bois J., and Lebesque J.V. Strategies to reduce the systematic error due to tumor and rectum motion in radiotherapy of prostate cancer. Radiother Oncol 74 (2005) 177-185
    • (2005) Radiother Oncol , vol.74 , pp. 177-185
    • Hoogeman, M.S.1    van Herk, M.2    de Bois, J.3    Lebesque, J.V.4
  • 13
    • 0033753216 scopus 로고    scopus 로고
    • Ultrasound-based stereotactic guidance in prostate cancer - quantification of organ motion and set-up erros in external beam radiation therapy
    • Lattanzi J., McNeeley S., Donnelly S., et al. Ultrasound-based stereotactic guidance in prostate cancer - quantification of organ motion and set-up erros in external beam radiation therapy. Comput Aided Surg 5 (2000) 289-295
    • (2000) Comput Aided Surg , vol.5 , pp. 289-295
    • Lattanzi, J.1    McNeeley, S.2    Donnelly, S.3
  • 14
    • 0036680186 scopus 로고    scopus 로고
    • Implementation and utility of a daily ultrasound-based localization system with intensity-modulated radiotherapy for prostate cancer
    • Morr J., DiPetrillo T., Tsai J.S., et al. Implementation and utility of a daily ultrasound-based localization system with intensity-modulated radiotherapy for prostate cancer. Int J Radiat Oncol Biol Phys 53 (2002) 1124-1129
    • (2002) Int J Radiat Oncol Biol Phys , vol.53 , pp. 1124-1129
    • Morr, J.1    DiPetrillo, T.2    Tsai, J.S.3
  • 15
    • 0038303679 scopus 로고    scopus 로고
    • Rectal dose sparing with a balloon catheter and ultrasound localization in conformal radiation therapy for prostate cancer
    • Patel R.R., Orton N., Tome W.A., Chappell R., and Ritter M.A. Rectal dose sparing with a balloon catheter and ultrasound localization in conformal radiation therapy for prostate cancer. Radiother Oncol 67 (2003) 285-294
    • (2003) Radiother Oncol , vol.67 , pp. 285-294
    • Patel, R.R.1    Orton, N.2    Tome, W.A.3    Chappell, R.4    Ritter, M.A.5
  • 16
    • 0036680314 scopus 로고    scopus 로고
    • Prostate cancer radiation dose response: results of the M.D. Anderson phase III randomized trial
    • Pollack A., Zagars G.K., Starkschall G., et al. Prostate cancer radiation dose response: results of the M.D. Anderson phase III randomized trial. Int J Radiat Oncol Biol Phys 53 (2002) 1097-1105
    • (2002) Int J Radiat Oncol Biol Phys , vol.53 , pp. 1097-1105
    • Pollack, A.1    Zagars, G.K.2    Starkschall, G.3
  • 17
    • 0034653323 scopus 로고    scopus 로고
    • 3-D portal image analysis in clinical practice: an evaluation of 2-D and 3-D analysis techniques as applied to 30 prostate cancer patients
    • Remeijer P., Geerlof E., Ploeger L., et al. 3-D portal image analysis in clinical practice: an evaluation of 2-D and 3-D analysis techniques as applied to 30 prostate cancer patients. Int J Radiat Oncol Biol Phys 46 (2000) 1281-1290
    • (2000) Int J Radiat Oncol Biol Phys , vol.46 , pp. 1281-1290
    • Remeijer, P.1    Geerlof, E.2    Ploeger, L.3
  • 18
    • 0034307033 scopus 로고    scopus 로고
    • Complications from radiotherapy dose escalation in prostate cancer: preliminary results of a randomized trial
    • Storey M.R., Pollack A., Zagars G., et al. Complications from radiotherapy dose escalation in prostate cancer: preliminary results of a randomized trial. Int J Radiat Oncol Biol Phys 48 (2000) 635-642
    • (2000) Int J Radiat Oncol Biol Phys , vol.48 , pp. 635-642
    • Storey, M.R.1    Pollack, A.2    Zagars, G.3
  • 19
    • 11144352756 scopus 로고    scopus 로고
    • The effect of an endorectal balloon and off-line correction on the inter-imaging systematic and random prostate position variations: a comparative study
    • Van Lin E.N.J.T., Van Der Vight L.P., Witjes J.A., et al. The effect of an endorectal balloon and off-line correction on the inter-imaging systematic and random prostate position variations: a comparative study. Int J Radiat Oncol Biol Phys 61 (2005) 278-288
    • (2005) Int J Radiat Oncol Biol Phys , vol.61 , pp. 278-288
    • Van Lin, E.N.J.T.1    Van Der Vight, L.P.2    Witjes, J.A.3
  • 20
    • 33750736868 scopus 로고    scopus 로고
    • Controlling geometry in prostate irradiation: implanted markers and endorectal balloons
    • Visser A.G., van Lin E.N.J.T., Hoffmann A.L., et al. Controlling geometry in prostate irradiation: implanted markers and endorectal balloons. Radiother Oncol 68 (2003) S34
    • (2003) Radiother Oncol , vol.68
    • Visser, A.G.1    van Lin, E.N.J.T.2    Hoffmann, A.L.3
  • 21
    • 0034891284 scopus 로고    scopus 로고
    • High dose radiation delivered by intensity modulated conformal radiotherapy improves the outcome of localized prostate cancer
    • Zelefsky M.J., Fuks Z., Hunt M., et al. High dose radiation delivered by intensity modulated conformal radiotherapy improves the outcome of localized prostate cancer. J Urol 166 (2001) 876-881
    • (2001) J Urol , vol.166 , pp. 876-881
    • Zelefsky, M.J.1    Fuks, Z.2    Hunt, M.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.