메뉴 건너뛰기




Volumn 17, Issue 12, 2006, Pages 1310-1319

Improving SVT discrimination in single-chamber ICDs: A new electrogram morphology-based algorithm

Author keywords

Implantable cardioverter defibrillator; SVT discrimination; Tachyarrhythmias

Indexed keywords

ADULT; AGED; ALGORITHM; ARTICLE; DEFIBRILLATOR; ELECTROGRAPHY; FEMALE; HEART BUNDLE BRANCH BLOCK; HEART VENTRICLE TACHYCARDIA; HUMAN; MAJOR CLINICAL STUDY; MALE; PERFORMANCE; PRIORITY JOURNAL; SENSITIVITY AND SPECIFICITY; SUPRAVENTRICULAR TACHYCARDIA;

EID: 33750695506     PISSN: 10453873     EISSN: 15408167     Source Type: Journal    
DOI: 10.1111/j.1540-8167.2006.00643.x     Document Type: Article
Times cited : (80)

References (31)
  • 2
    • 7744220529 scopus 로고    scopus 로고
    • Randomized controlled study of detection enhancements versus rate-only detection to prevent inappropriate therapy in a dual-chamber implantable cardioverter-defibrillator
    • Dorian P, Philippon F, Thibault B, Kimber S, Sterns L, Greene M, Newman D, Gelaznikas R, Barr A: Randomized controlled study of detection enhancements versus rate-only detection to prevent inappropriate therapy in a dual-chamber implantable cardioverter-defibrillator. Heart Rhythm 2004;1:540-547.
    • (2004) Heart Rhythm , vol.1 , pp. 540-547
    • Dorian, P.1    Philippon, F.2    Thibault, B.3    Kimber, S.4    Sterns, L.5    Greene, M.6    Newman, D.7    Gelaznikas, R.8    Barr, A.9
  • 3
    • 10644292742 scopus 로고    scopus 로고
    • Prevention of inappropriate therapy in implantable cardioverter- defibrillators: Results of a prospective, randomized study of tachyarrhythmia detection algorithms
    • Theuns DA, Klootwijk AP, Goedhart DM, Jordaens LJ: Prevention of inappropriate therapy in implantable cardioverter-defibrillators: Results of a prospective, randomized study of tachyarrhythmia detection algorithms. J Am Coll Cardiol 2004;44:2362-2367.
    • (2004) J Am Coll Cardiol , vol.44 , pp. 2362-2367
    • Theuns, D.A.1    Klootwijk, A.P.2    Goedhart, D.M.3    Jordaens, L.J.4
  • 4
    • 7544220287 scopus 로고    scopus 로고
    • Prospective randomized multicenter trial of empirical antitachycardia pacing versus shocks for spontaneous rapid ventricular tachycardia in patients with implantable cardioverter-defibrillators: Pacing Fast Ventricular Tachycardia Reduces Shock Therapies (PainFREE Rx II) trial results
    • Wathen MS, DeGroot PJ, Sweeney MO, Stark AJ, Otterness MF, Adkisson WO, Canby RC, Khalighi K, Machado C, Rubenstein DS, Volosin KJ: Prospective randomized multicenter trial of empirical antitachycardia pacing versus shocks for spontaneous rapid ventricular tachycardia in patients with implantable cardioverter-defibrillators: Pacing Fast Ventricular Tachycardia Reduces Shock Therapies (PainFREE Rx II) trial results. Circulation 2004;110:2591-2596.
    • (2004) Circulation , vol.110 , pp. 2591-2596
    • Wathen, M.S.1    DeGroot, P.J.2    Sweeney, M.O.3    Stark, A.J.4    Otterness, M.F.5    Adkisson, W.O.6    Canby, R.C.7    Khalighi, K.8    Machado, C.9    Rubenstein, D.S.10    Volosin, K.J.11
  • 5
    • 33644693959 scopus 로고    scopus 로고
    • Complications of implantable cardioverter defibrillator therapy in 440 consecutive patients
    • Alter P, Waldhans S, Plachta E, Moosdorf R, Grimm W: Complications of implantable cardioverter defibrillator therapy in 440 consecutive patients. Pacing Clin Electrophysiol 2005;28:926-932.
    • (2005) Pacing Clin Electrophysiol , vol.28 , pp. 926-932
    • Alter, P.1    Waldhans, S.2    Plachta, E.3    Moosdorf, R.4    Grimm, W.5
  • 6
    • 13244260702 scopus 로고    scopus 로고
    • Implantable cardioverter-defibrillators, induced anxiety, and quality of life
    • Sola CL, Bostwick JM: Implantable cardioverter-defibrillators, induced anxiety, and quality of life. Mayo Clin Proc 2005;80:232-237.
    • (2005) Mayo Clin Proc , vol.80 , pp. 232-237
    • Sola, C.L.1    Bostwick, J.M.2
  • 7
    • 32944470264 scopus 로고    scopus 로고
    • Predictors of quality of life in patients with implantable cardioverter defibrillators
    • Sears SF, Lewis TS, Kuhl EA, Conti JB: Predictors of quality of life in patients with implantable cardioverter defibrillators. Psychosomatics 2005;46:451-457.
    • (2005) Psychosomatics , vol.46 , pp. 451-457
    • Sears, S.F.1    Lewis, T.S.2    Kuhl, E.A.3    Conti, J.B.4
  • 8
    • 0037339924 scopus 로고    scopus 로고
    • Understanding implantable cardioverter defibrillator shocks and storms: Medical and psychosocial considerations for research and clinical care
    • Sears SE Jr., Conti JB: Understanding implantable cardioverter defibrillator shocks and storms: Medical and psychosocial considerations for research and clinical care. Clin Cardiol 2003;26:107-111.
    • (2003) Clin Cardiol , vol.26 , pp. 107-111
    • Sears Jr., S.E.1    Conti, J.B.2
  • 11
    • 18944406617 scopus 로고    scopus 로고
    • Quality of life in implanted cardioverter defibrillator recipients: The impact of a device shock
    • Carroll DL, Hamilton GA: Quality of life in implanted cardioverter defibrillator recipients: The impact of a device shock. Heart Lung 2005;34:169-178.
    • (2005) Heart Lung , vol.34 , pp. 169-178
    • Carroll, D.L.1    Hamilton, G.A.2
  • 12
    • 17044420522 scopus 로고    scopus 로고
    • Measuring patient acceptance of implantable cardiac device therapy: Initial psychometric investigation of the Florida Patient Acceptance Survey
    • Burns JL, Serber ER, Keim S, Sears SF: Measuring patient acceptance of implantable cardiac device therapy: Initial psychometric investigation of the Florida Patient Acceptance Survey. J Cardiovasc Electrophysiol 2005;16:384-390.
    • (2005) J Cardiovasc Electrophysiol , vol.16 , pp. 384-390
    • Burns, J.L.1    Serber, E.R.2    Keim, S.3    Sears, S.F.4
  • 14
    • 14644422645 scopus 로고    scopus 로고
    • Inappropriate therapy and fatal proarrhythmia by an implantable cardioverter-defibrillator
    • Vollmann D, Luthje L, Vonhof S, Unterberg C: Inappropriate therapy and fatal proarrhythmia by an implantable cardioverter-defibrillator. Heart Rhythm 2005;2:307-309.
    • (2005) Heart Rhythm , vol.2 , pp. 307-309
    • Vollmann, D.1    Luthje, L.2    Vonhof, S.3    Unterberg, C.4
  • 17
    • 0031464459 scopus 로고    scopus 로고
    • Underdetection of ventricular tachycardia using a 40 ms stability criterion: Effect of antiarrhythmic therapy
    • Le Franc P, Kus T, Vinet A, Rocque P, Molin F, Costi P: Underdetection of ventricular tachycardia using a 40 ms stability criterion: Effect of antiarrhythmic therapy. Pacing Clin Electrophysiol 1997;20(12 Pt 1):2882-2892.
    • (1997) Pacing Clin Electrophysiol , vol.20 , Issue.12 PART 1 , pp. 2882-2892
    • Le Franc, P.1    Kus, T.2    Vinet, A.3    Rocque, P.4    Molin, F.5    Costi, P.6
  • 18
    • 0028941056 scopus 로고
    • Programmable VT detection enhancements in implantable cardioverter defibrillator therapy
    • Neuzner J, Pitschner HF, Schlepper M: Programmable VT detection enhancements in implantable cardioverter defibrillator therapy. Pacing Clin Electrophysiol 1995;18(3 Pt 2):539-547.
    • (1995) Pacing Clin Electrophysiol , vol.18 , Issue.3 PART 2 , pp. 539-547
    • Neuzner, J.1    Pitschner, H.F.2    Schlepper, M.3
  • 19
    • 0030581450 scopus 로고    scopus 로고
    • Enhanced detection criteria in implantable cardioverter-defibrillators to avoid inappropriate therapy
    • Schaumann A, von zur Muhlen F, Gonska BD, Kreuzer H: Enhanced detection criteria in implantable cardioverter-defibrillators to avoid inappropriate therapy. Am J Cardiol 1996;78(5A):42-50.
    • (1996) Am J Cardiol , vol.78 , Issue.5 A , pp. 42-50
    • Schaumann, A.1    Von Zur Muhlen, F.2    Gonska, B.D.3    Kreuzer, H.4
  • 20
    • 0028074708 scopus 로고
    • Underdetection of ventricular tachycardia by algorithms to enhance specificity in a tiered-therapy cardioverter-defibrillator
    • Swerdlow CD, Ahern T, Chen PS, Hwang C, Gang E, Mandel W, Kass RM, Peter CT: Underdetection of ventricular tachycardia by algorithms to enhance specificity in a tiered-therapy cardioverter-defibrillator. JAm Coll Cardiol 1994;24:416-424.
    • (1994) JAm Coll Cardiol , vol.24 , pp. 416-424
    • Swerdlow, C.D.1    Ahern, T.2    Chen, P.S.3    Hwang, C.4    Gang, E.5    Mandel, W.6    Kass, R.M.7    Peter, C.T.8
  • 21
    • 0031857916 scopus 로고    scopus 로고
    • Intracardiac QRS electrogram width-an arrhythmia detection feature for implantable cardioverter defibrillators: Exercise induced variation as a base for device programming
    • Klingenheben T, Sticherling C, Skupin M, Hohnloser SH: Intracardiac QRS electrogram width-an arrhythmia detection feature for implantable cardioverter defibrillators: Exercise induced variation as a base for device programming. Pacing Clin Electrophysiol 1998;21:1609-1617.
    • (1998) Pacing Clin Electrophysiol , vol.21 , pp. 1609-1617
    • Klingenheben, T.1    Sticherling, C.2    Skupin, M.3    Hohnloser, S.H.4
  • 26
    • 0036257741 scopus 로고    scopus 로고
    • Discrimination of ventricular tachycardia from supraventricular tachycardia by a downloadedwavelet-transform morphology algorithm: Aparadigm for development of implantable cardioverter defibrillator detection algorithms
    • Swerdlow CD, Brown ML, Lurie K, Zhang J, Wood NM, Olson WH, Gillberg JM: Discrimination of ventricular tachycardia from supraventricular tachycardia by a downloadedwavelet-transform morphology algorithm: Aparadigm for development of implantable cardioverter defibrillator detection algorithms. J Cardiovasc Electrophysiol 2002;13:432-441.
    • (2002) J Cardiovasc Electrophysiol , vol.13 , pp. 432-441
    • Swerdlow, C.D.1    Brown, M.L.2    Lurie, K.3    Zhang, J.4    Wood, N.M.5    Olson, W.H.6    Gillberg, J.M.7
  • 27
    • 0024205301 scopus 로고
    • Models for longitudinal data: A generalized estimating equation approach
    • Zeger SL, Liang KY, Albert PS: Models for longitudinal data: A generalized estimating equation approach. Biometrics 1988;44:1049-1060.
    • (1988) Biometrics , vol.44 , pp. 1049-1060
    • Zeger, S.L.1    Liang, K.Y.2    Albert, P.S.3
  • 29
    • 0035936534 scopus 로고    scopus 로고
    • Critical analysis of dual-chamber implantable cardioverter-defibrillator arrhythmia detection: Results and technical considerations
    • Wilkoff BL, Kuhlkamp V, Volosin K, Ellenbogen K, Waldecker B, Kacet S, Gillberg JM, DeSouza CM: Critical analysis of dual-chamber implantable cardioverter-defibrillator arrhythmia detection: Results and technical considerations. Circulation 2001;103:381-386.
    • (2001) Circulation , vol.103 , pp. 381-386
    • Wilkoff, B.L.1    Kuhlkamp, V.2    Volosin, K.3    Ellenbogen, K.4    Waldecker, B.5    Kacet, S.6    Gillberg, J.M.7    DeSouza, C.M.8
  • 31
    • 0033942379 scopus 로고    scopus 로고
    • Pitfalls of the concept of incremental specificity used in comparisons of dual chamber VT/VF detection algorithms
    • Malik M: Pitfalls of the concept of incremental specificity used in comparisons of dual chamber VT/VF detection algorithms. Pacing Clin Electrophysiol 2000;23:1166-1170.
    • (2000) Pacing Clin Electrophysiol , vol.23 , pp. 1166-1170
    • Malik, M.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.