메뉴 건너뛰기




Volumn 44, Issue 11, 2006, Pages 1330-1334

Urine flow cytometry and detection of glomerular hematuria

Author keywords

Glomerular hematuria; Non glomerular hematuria; Sediment analysis; Urine flow cytometry

Indexed keywords

ADOLESCENT; ADULT; AGED; ARTICLE; BLEEDING; CHILD; DEVICE; DISEASE CLASSIFICATION; ERYTHROCYTE; ERYTHROCYTE URINE LEVEL; FEMALE; FLOW CYTOMETRY; GLOMERULAR HEMATURIA; GLOMERULOPATHY; HEMATURIA; HUMAN; INFANT; KIDNEY DISEASE; LABORATORY TEST; MAJOR CLINICAL STUDY; MALE; MICTURITION; NEWBORN; PRIORITY JOURNAL; SENSITIVITY AND SPECIFICITY; URINALYSIS; URINE SEDIMENT;

EID: 33750687904     PISSN: 14346621     EISSN: 14346621     Source Type: Journal    
DOI: 10.1515/CCLM.2006.248     Document Type: Article
Times cited : (12)

References (22)
  • 1
    • 0023268696 scopus 로고
    • The significance of asymptomatic microhematuria in men 50 or more years old: Findings of a home screening study using urinary dipsticks
    • Messing EM, Young TB, Hunt VB, Emoto SE, Wehbie JM. The significance of asymptomatic microhematuria in men 50 or more years old: findings of a home screening study using urinary dipsticks. J Urol 1987;137:919-22.
    • (1987) J Urol , vol.137 , pp. 919-922
    • Messing, E.M.1    Young, T.B.2    Hunt, V.B.3    Emoto, S.E.4    Wehbie, J.M.5
  • 2
    • 0024427807 scopus 로고
    • Dipstick haematuria and bladder cancer in men over 60: Results of a community study
    • Britton JP, Dowell AC, Whelan P. Dipstick haematuria and bladder cancer in men over 60: results of a community study. Br Med J 1989;299:1010-2.
    • (1989) Br Med J , vol.299 , pp. 1010-1012
    • Britton, J.P.1    Dowell, A.C.2    Whelan, P.3
  • 3
    • 0018797399 scopus 로고
    • Haematuria: Glomerular or non-glomerular?
    • Birch DF, Fairley KF. Haematuria: glomerular or non-glomerular? Lancet 1979;2:845-6.
    • (1979) Lancet , vol.2 , pp. 845-846
    • Birch, D.F.1    Fairley, K.F.2
  • 4
    • 0020053362 scopus 로고
    • Hematuria: A simple method for identifying glomerular bleeding
    • Fairley KF, Birch DF. Hematuria: a simple method for identifying glomerular bleeding. Kidney Int 1982;21:105-8.
    • (1982) Kidney Int , vol.21 , pp. 105-108
    • Fairley, K.F.1    Birch, D.F.2
  • 6
    • 0025816179 scopus 로고
    • Acanthocyturia - A characteristic marker for glomerular bleeding
    • Köhler H, Wandel E, Brunck B. Acanthocyturia - a characteristic marker for glomerular bleeding. Kidney Int 1991;40:115-20.
    • (1991) Kidney Int , vol.40 , pp. 115-120
    • Köhler, H.1    Wandel, E.2    Brunck, B.3
  • 8
    • 0016366144 scopus 로고
    • Urine microscopy, an ill-defined method, examined by a multifactorial technique
    • Winkel P, Statland BE, Jorgensen K. Urine microscopy, an ill-defined method, examined by a multifactorial technique. Clin Chem 1974;20:436-9.
    • (1974) Clin Chem , vol.20 , pp. 436-439
    • Winkel, P.1    Statland, B.E.2    Jorgensen, K.3
  • 9
    • 0023033282 scopus 로고
    • A blind controlled trial of phase-contrast microscopy by two observers for evaluating the source of haematuria
    • Venkat Raman G, Pead L, Lee HA, Maskell R. A blind controlled trial of phase-contrast microscopy by two observers for evaluating the source of haematuria. Nephron 1986;44:304-8.
    • (1986) Nephron , vol.44 , pp. 304-308
    • Venkat Raman, G.1    Pead, L.2    Lee, H.A.3    Maskell, R.4
  • 11
    • 0033883130 scopus 로고    scopus 로고
    • European urinalysis guidelines
    • European Confederation of Laboratory Medicine
    • European Confederation of Laboratory Medicine. European urinalysis guidelines. Scand J Clin Lab Invest Suppl 2000;231:1-86.
    • (2000) Scand J Clin Lab Invest Suppl , vol.231 , pp. 1-86
  • 12
    • 0032418219 scopus 로고    scopus 로고
    • The automation of sediment urinalysis using a new urine flow cytometer (UF-100)
    • Fenili D, Pirovano B. The automation of sediment urinalysis using a new urine flow cytometer (UF-100). Clin Chem Lab Med 1998;36:909-17.
    • (1998) Clin Chem Lab Med , vol.36 , pp. 909-917
    • Fenili, D.1    Pirovano, B.2
  • 13
    • 0032858501 scopus 로고    scopus 로고
    • Automation of urine sediment examination: A comparison of the Sysmex UF-100 automated flow cytometer with routine manual diagnosis (microscopy, test strips, and bacterial culture)
    • Hannemann-Pohl K, Kampf SC. Automation of urine sediment examination: a comparison of the Sysmex UF-100 automated flow cytometer with routine manual diagnosis (microscopy, test strips, and bacterial culture). Clin Chem Lab Med 1999;37:753-64.
    • (1999) Clin Chem Lab Med , vol.37 , pp. 753-764
    • Hannemann-Pohl, K.1    Kampf, S.C.2
  • 15
    • 0035010759 scopus 로고    scopus 로고
    • Urine analysis performed by flow cytometry: Reference range determination and comparison to morphological findings, dipstick chemistry and bacterial culture results - A multicenter study
    • Regeniter A, Haenni V, Risch L, Kochli HP, Colombo JP, Frei R, et al. Urine analysis performed by flow cytometry: reference range determination and comparison to morphological findings, dipstick chemistry and bacterial culture results - a multicenter study. Clin Nephrol 2001;55:384-92.
    • (2001) Clin Nephrol , vol.55 , pp. 384-392
    • Regeniter, A.1    Haenni, V.2    Risch, L.3    Kochli, H.P.4    Colombo, J.P.5    Frei, R.6
  • 16
    • 0023895690 scopus 로고
    • Red-cell-volume distribution curves in diagnosis of glomerular and non-glomerular haematuria
    • Shichiri M, Hosoda K, Nishio Y, Ogura M, Suenaga M, Saito H, et al. Red-cell-volume distribution curves in diagnosis of glomerular and non-glomerular haematuria. Lancet 1988;1:908-11.
    • (1988) Lancet , vol.1 , pp. 908-911
    • Shichiri, M.1    Hosoda, K.2    Nishio, Y.3    Ogura, M.4    Suenaga, M.5    Saito, H.6
  • 17
    • 0343883507 scopus 로고    scopus 로고
    • Evaluation of Sysmex UF-100 urine flow cytometer vs. chamber counting of supravitally stained specimens and conventional bacterial cultures
    • Kouri TT, Kahkonen U, Malminiemi K, Vuento R, Rowan RM. Evaluation of Sysmex UF-100 urine flow cytometer vs. chamber counting of supravitally stained specimens and conventional bacterial cultures. Am J Clin Pathol 1999;112:25-35.
    • (1999) Am J Clin Pathol , vol.112 , pp. 25-35
    • Kouri, T.T.1    Kahkonen, U.2    Malminiemi, K.3    Vuento, R.4    Rowan, R.M.5
  • 18
    • 33750729504 scopus 로고    scopus 로고
    • Sysmex Corporation. Kobe, Japan: Sysmex
    • Sysmex Corporation. Clinical case study 2. Kobe, Japan: Sysmex, 2001:13-4.
    • (2001) Clinical Case Study 2 , pp. 13-14
  • 19
    • 0032867308 scopus 로고    scopus 로고
    • Differential diagnosis between glomerular and nonglomerular hematuria by automated urinary flow cytometer. Kitasato University Kidney Center criteria
    • Hyodo T, Kumano K, Sakai T. Differential diagnosis between glomerular and nonglomerular hematuria by automated urinary flow cytometer. Kitasato University Kidney Center criteria. Nephron 1999;82:312-23.
    • (1999) Nephron , vol.82 , pp. 312-323
    • Hyodo, T.1    Kumano, K.2    Sakai, T.3
  • 20
    • 0034871859 scopus 로고    scopus 로고
    • Assessment of haematuria: Automated urine flowmetry vs. microscopy
    • Apeland T, Mestad O, Hetland O. Assessment of haematuria: automated urine flowmetry vs. microscopy. Nephrol Dial Transplant 2001;16:1615-19.
    • (2001) Nephrol Dial Transplant , vol.16 , pp. 1615-1619
    • Apeland, T.1    Mestad, O.2    Hetland, O.3
  • 21
    • 0041942553 scopus 로고    scopus 로고
    • Microscopic urinalysis and automated flow cytometry in a nephrology laboratory
    • Gai M, Piccoli GB, Segoloni GP, Lanfranco G. Microscopic urinalysis and automated flow cytometry in a nephrology laboratory. Clin Chem 2003;49:1559-60.
    • (2003) Clin Chem , vol.49 , pp. 1559-1560
    • Gai, M.1    Piccoli, G.B.2    Segoloni, G.P.3    Lanfranco, G.4
  • 22
    • 0037334168 scopus 로고    scopus 로고
    • Comparison of red blood cell volume distribution curves and phase-contrast microscopy in localization of the origin of hematuria
    • Game X, Soulie M, Fontanilles A, Benoit J-M, Corberand J-X, Plante P. Comparison of red blood cell volume distribution curves and phase-contrast microscopy in localization of the origin of hematuria. Urology 2003;61:507-11.
    • (2003) Urology , vol.61 , pp. 507-511
    • Game, X.1    Soulie, M.2    Fontanilles, A.3    Benoit, J.-M.4    Corberand, J.-X.5    Plante, P.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.