메뉴 건너뛰기




Volumn 49, Issue 9, 2003, Pages 1559-1560

Microscopic urinalysis and automated flow cytometry in a nephrology laboratory [7]

Author keywords

[No Author keywords available]

Indexed keywords

AUTOANALYSIS; COMPUTER PROGRAM; ERYTHROCYTE SHAPE; FLOW CYTOMETRY; HUMAN; INTERMETHOD COMPARISON; LETTER; LEUKOCYTE; MAJOR CLINICAL STUDY; MICROSCOPY; URINALYSIS;

EID: 0041942553     PISSN: 00099147     EISSN: None     Source Type: Journal    
DOI: 10.1373/49.9.1559     Document Type: Letter
Times cited : (8)

References (8)
  • 1
    • 0037380114 scopus 로고    scopus 로고
    • Quantitative urine particle analysis: Integrative approach for the optimal combination of automation with UF-100 and microscopic review with KOVA cell chamber
    • Ottiger C, Huber AR. Quantitative urine particle analysis: integrative approach for the optimal combination of automation with UF-100 and microscopic review with KOVA cell chamber. Clin Chem 2003;49:617-23.
    • (2003) Clin Chem , vol.49 , pp. 617-623
    • Ottiger, C.1    Huber, A.R.2
  • 2
    • 0031982981 scopus 로고    scopus 로고
    • Evaluation of the Sysmex UF-100 automated urinalysis analyzer
    • Ben-Ezra J, Bork L, McPherson RA. Evaluation of the Sysmex UF-100 automated urinalysis analyzer. Clin Chem 1998;44:92-5.
    • (1998) Clin Chem , vol.44 , pp. 92-95
    • Ben-Ezra, J.1    Bork, L.2    McPherson, R.A.3
  • 4
    • 0344994653 scopus 로고    scopus 로고
    • Routine workflow for use of urine strips and urine flow cytometer UF-100 in the hospital laboratory
    • Lun A, Ziebig R, Priem F, Filler G, Sinha P. Routine workflow for use of urine strips and urine flow cytometer UF-100 in the hospital laboratory. Clin Chem 1999;45:1305-7.
    • (1999) Clin Chem , vol.45 , pp. 1305-1307
    • Lun, A.1    Ziebig, R.2    Priem, F.3    Filler, G.4    Sinha, P.5
  • 5
    • 0033883130 scopus 로고    scopus 로고
    • European urinalysis guidelines
    • European Urinalysis Group. European urinalysis guidelines. Scand J Lab Invest 2000;60:1-96.
    • (2000) Scand J Lab Invest , vol.60 , pp. 1-96
  • 6
    • 0034871859 scopus 로고    scopus 로고
    • Assessment of haematuria: Automated urine flowmetry vs microscopy
    • Apeland T, Mestad O, Hetland O. Assessment of haematuria: automated urine flowmetry vs microscopy. Nephrol Dial Transplant 2001;16:1615-9.
    • (2001) Nephrol Dial Transplant , vol.16 , pp. 1615-1619
    • Apeland, T.1    Mestad, O.2    Hetland, O.3
  • 7
    • 0032867308 scopus 로고    scopus 로고
    • Differential diagnosis between glomerular and nonglomerular haematuria by automated urinary flow cytometer. Kitasato University Kidney Center criteria
    • Hyodo T, Kumano K, Sakai T. Differential diagnosis between glomerular and nonglomerular haematuria by automated urinary flow cytometer. Kitasato University Kidney Center criteria. Nephron 1999;82:312-23.
    • (1999) Nephron , vol.82 , pp. 312-323
    • Hyodo, T.1    Kumano, K.2    Sakai, T.3
  • 8
    • 0025816179 scopus 로고
    • Acanthocyturia - A characteristic marker for glomerular bleeding
    • Kohler H, Wandel E, Brunck B. Acanthocyturia - a characteristic marker for glomerular bleeding. Kidney Int 1991;40:115-20.
    • (1991) Kidney Int , vol.40 , pp. 115-120
    • Kohler, H.1    Wandel, E.2    Brunck, B.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.