메뉴 건너뛰기




Volumn 299, Issue 4-5, 2007, Pages 757-773

Vibration control of a tall building subjected to earthquake excitation

Author keywords

[No Author keywords available]

Indexed keywords

COMPUTER SIMULATION; COST EFFECTIVENESS; DAMPING; EARTHQUAKE EFFECTS; SLIDING MODE CONTROL; VIBRATION CONTROL;

EID: 33750626198     PISSN: 0022460X     EISSN: 10958568     Source Type: Journal    
DOI: 10.1016/j.jsv.2006.07.016     Document Type: Article
Times cited : (87)

References (17)
  • 5
    • 0023983333 scopus 로고
    • Variable structure control of nonlinear multivariable system: a tutorial
    • DeCarlo R.A., Zak S.H., and Matthnews G.P. Variable structure control of nonlinear multivariable system: a tutorial. IEEE 76 (1988) 212-232
    • (1988) IEEE , vol.76 , pp. 212-232
    • DeCarlo, R.A.1    Zak, S.H.2    Matthnews, G.P.3
  • 7
    • 0016368711 scopus 로고
    • Application of fuzzy algorithms for control of simple dynamic plants
    • Mamdani E.H. Application of fuzzy algorithms for control of simple dynamic plants. IEE 121 12 (1974) 1585-1588
    • (1974) IEE , vol.121 , Issue.12 , pp. 1585-1588
    • Mamdani, E.H.1
  • 9
    • 0022957445 scopus 로고
    • Fuzzy logic for estimation of earthquake intensity based on building damage records
    • Juang C., and Elton D.J. Fuzzy logic for estimation of earthquake intensity based on building damage records. Civil Engineering System 3 (1986) 187-191
    • (1986) Civil Engineering System , vol.3 , pp. 187-191
    • Juang, C.1    Elton, D.J.2
  • 11
    • 0029778487 scopus 로고    scopus 로고
    • Simple ATMD control methodology for buildings subject to wind loads
    • Ankireddi S., and Yang H.T.Y. Simple ATMD control methodology for buildings subject to wind loads. Journal of the Structure Division, ASCE 122 (1996) 83-91
    • (1996) Journal of the Structure Division, ASCE , vol.122 , pp. 83-91
    • Ankireddi, S.1    Yang, H.T.Y.2
  • 12
    • 0030164806 scopus 로고    scopus 로고
    • Effectiveness of active tuned mass damper and seismic isolation on vibration control of multi-story building
    • Loh C.H., and Chao C.H. Effectiveness of active tuned mass damper and seismic isolation on vibration control of multi-story building. Journal of Sound and Vibration 193 4 (1996) 773-792
    • (1996) Journal of Sound and Vibration , vol.193 , Issue.4 , pp. 773-792
    • Loh, C.H.1    Chao, C.H.2
  • 13
    • 0031248548 scopus 로고    scopus 로고
    • Critical mode control of a wind-loaded building using an active tuned mass damper
    • Mackriell L.E., Kwok K.C.S., and Samali B. Critical mode control of a wind-loaded building using an active tuned mass damper. Engineering Structures 19 (1997) 834-842
    • (1997) Engineering Structures , vol.19 , pp. 834-842
    • Mackriell, L.E.1    Kwok, K.C.S.2    Samali, B.3
  • 14
    • 0035963535 scopus 로고    scopus 로고
    • Dynamic analysis of a tall building with a tuned-mass-damper device subjected to earthquake excitation
    • Wang A.P., Fung R.F., and Huang S.C. Dynamic analysis of a tall building with a tuned-mass-damper device subjected to earthquake excitation. Journal of Sound and Vibration 244 1 (2001)
    • (2001) Journal of Sound and Vibration , vol.244 , Issue.1
    • Wang, A.P.1    Fung, R.F.2    Huang, S.C.3
  • 16
    • 0031648099 scopus 로고    scopus 로고
    • Finite element analysis of a three-dimensional underwater cable with time-dependent length
    • Wang P.H., Fung R.F., and Lee M.J. Finite element analysis of a three-dimensional underwater cable with time-dependent length. Journal Sound and Vibration 209 2 (1998) 223-249
    • (1998) Journal Sound and Vibration , vol.209 , Issue.2 , pp. 223-249
    • Wang, P.H.1    Fung, R.F.2    Lee, M.J.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.