메뉴 건너뛰기




Volumn 24, Issue 5, 2006, Pages 1159-1167

Improved myocardial tagging contrast in cine balanced SSFP images

Author keywords

Cardiac MRI; CSPAMM tagging; SNR; SPGR; SSFP

Indexed keywords

ADULT; ARTICLE; AUTOANALYSIS; COMPLEMENTARY SPATIAL MODULATION OF MAGNETIZATION TAGGING; COMPUTER SIMULATION; CONTRAST ENHANCEMENT; CONTRAST TO NOISE RATIO; CONTROLLED STUDY; DIAGNOSTIC IMAGING; DIASTOLE; HEART CYCLE; HUMAN; IMAGE ANALYSIS; IMAGE ENHANCEMENT; IMAGE PROCESSING; IMAGE QUALITY; INTERMETHOD COMPARISON; MEASUREMENT; METHODOLOGY; MYOCARDIAL TAGGING; NORMAL HUMAN; NUCLEAR MAGNETIC RESONANCE IMAGING; PRIORITY JOURNAL; PROCESS OPTIMIZATION; QUANTITATIVE ANALYSIS; RADIOFREQUENCY; SPOILED GRADIENT ECHO IMAGING; STEADY STATE FREE PRECESSION IMAGING; TECHNIQUE;

EID: 33750436925     PISSN: 10531807     EISSN: 15222586     Source Type: Journal    
DOI: 10.1002/jmri.20730     Document Type: Article
Times cited : (28)

References (34)
  • 1
    • 0023737101 scopus 로고
    • Human heart: Tagging with MR imaging - A method for noninvasive assessment of myocardial motion
    • Zerhouni EA, Parish DM, Rogers WJ, Yang A, Shapiro EP. Human heart: tagging with MR imaging - a method for noninvasive assessment of myocardial motion. Radiology 1988;169:59-63.
    • (1988) Radiology , vol.169 , pp. 59-63
    • Zerhouni, E.A.1    Parish, D.M.2    Rogers, W.J.3    Yang, A.4    Shapiro, E.P.5
  • 2
    • 0024318208 scopus 로고
    • MR imaging of motion with spatial modulation of magnetization
    • Axei L, Dougherty L. MR imaging of motion with spatial modulation of magnetization. Radiology 1989;171:841-845.
    • (1989) Radiology , vol.171 , pp. 841-845
    • Axei, L.1    Dougherty, L.2
  • 3
    • 0027070940 scopus 로고
    • Cardiac tagging with breath-hold cine MRI
    • McVeigh ER, Atalar E. Cardiac tagging with breath-hold cine MRI. Magn Reson Med 1992;28:318-327.
    • (1992) Magn Reson Med , vol.28 , pp. 318-327
    • McVeigh, E.R.1    Atalar, E.2
  • 5
    • 0023872880 scopus 로고
    • An analysis of fast imaging sequences with steady-stale transverse magnetization refocusing
    • Zur Y, Stokar S, Bendel P. An analysis of fast imaging sequences with steady-stale transverse magnetization refocusing. Magn Reson Med 1988;6:175-193.
    • (1988) Magn Reson Med , vol.6 , pp. 175-193
    • Zur, Y.1    Stokar, S.2    Bendel, P.3
  • 7
    • 0023367344 scopus 로고
    • Steady-state magnetization in rapid NMR imaging using small flip angles and short repetition intervals
    • Sekihara K. Steady-state magnetization in rapid NMR imaging using small flip angles and short repetition intervals. IEEE Trans Med Imaging 1937;6:157-164.
    • (1937) IEEE Trans Med Imaging , vol.6 , pp. 157-164
    • Sekihara, K.1
  • 9
    • 0037381125 scopus 로고    scopus 로고
    • Steady-state free precession with myocardial tagging: CSPAMM in a single breathhold
    • Zwanenburg JJ, Kuijer JP, Marcus JT, Heethaar RM. Steady-state free precession with myocardial tagging: CSPAMM in a single breathhold. Magn Reson Med 2003;49:722-730.
    • (2003) Magn Reson Med , vol.49 , pp. 722-730
    • Zwanenburg, J.J.1    Kuijer, J.P.2    Marcus, J.T.3    Heethaar, R.M.4
  • 11
    • 0242439328 scopus 로고    scopus 로고
    • Principles and applications of balanced SSFP techniques
    • Scheffler K, Lehnhardt S. Principles and applications of balanced SSFP techniques. Eur Radiol 2003;13:2409-2418.
    • (2003) Eur Radiol , vol.13 , pp. 2409-2418
    • Scheffler, K.1    Lehnhardt, S.2
  • 12
    • 0036845522 scopus 로고    scopus 로고
    • Single-breathhold 3D-TrueFISP cine cardiac imaging
    • Jung BA, Hennig J, Scheffler K. Single-breathhold 3D-TrueFISP cine cardiac imaging. Magn Reson Med 2002;48:921-925.
    • (2002) Magn Reson Med , vol.48 , pp. 921-925
    • Jung, B.A.1    Hennig, J.2    Scheffler, K.3
  • 13
    • 1342266112 scopus 로고    scopus 로고
    • Steady-state free precession MR imaging: Improved myocardial tag persistence and signal-to-noise ratio for analysis of myocardial motion
    • Markl M, Reeder SB, Chan FP, Alley MT, Herfkens RJ, Pelc NJ. Steady-state free precession MR imaging: improved myocardial tag persistence and signal-to-noise ratio for analysis of myocardial motion. Radiology 2004;230:852-861.
    • (2004) Radiology , vol.230 , pp. 852-861
    • Markl, M.1    Reeder, S.B.2    Chan, F.P.3    Alley, M.T.4    Herfkens, R.J.5    Pelc, N.J.6
  • 14
    • 0034870344 scopus 로고    scopus 로고
    • Steady-state free precession magnetic resonance imaging of the heart: Comparison with segmented k-space gradient-echo imaging
    • Plein S, Bloomer TN, Ridgway JP, Jones TR, Bainbridge GJ, Sivananthan MU. Steady-state free precession magnetic resonance imaging of the heart: comparison with segmented k-space gradient-echo imaging. J Magn Reson Imaging 2001;14:230-236.
    • (2001) J Magn Reson Imaging , vol.14 , pp. 230-236
    • Plein, S.1    Bloomer, T.N.2    Ridgway, J.P.3    Jones, T.R.4    Bainbridge, G.J.5    Sivananthan, M.U.6
  • 15
    • 4644223318 scopus 로고    scopus 로고
    • Signal-to-noise ratio behavior of steady-state free precession
    • Reeder SB, Herzka DA, McVeigh ER. Signal-to-noise ratio behavior of steady-state free precession. Magn Reson Med 2004;52:123-130.
    • (2004) Magn Reson Med , vol.52 , pp. 123-130
    • Reeder, S.B.1    Herzka, D.A.2    McVeigh, E.R.3
  • 16
    • 0037382249 scopus 로고    scopus 로고
    • On the transient phase of balanced SSFP sequences
    • Schefller K. On the transient phase of balanced SSFP sequences. Magn Reson Med 2003;49:781-783.
    • (2003) Magn Reson Med , vol.49 , pp. 781-783
    • Schefller, K.1
  • 20
    • 0035009703 scopus 로고    scopus 로고
    • Magnetization preparation during the steady state: Fat-saturated 3D TrueFISP
    • Schefller K, Heid O, Hennig J. Magnetization preparation during the steady state: fat-saturated 3D TrueFISP. Magn Reson Med 2001;45:1075-1080.
    • (2001) Magn Reson Med , vol.45 , pp. 1075-1080
    • Schefller, K.1    Heid, O.2    Hennig, J.3
  • 21
    • 0032754849 scopus 로고    scopus 로고
    • Single breath-hold slice-following CSPAMM myocardial tagging
    • Stuber M, Spiegel MA, Fischer SE, et al. Single breath-hold slice-following CSPAMM myocardial tagging. MAGMA 1999;9:85-91.
    • (1999) MAGMA , vol.9 , pp. 85-91
    • Stuber, M.1    Spiegel, M.A.2    Fischer, S.E.3
  • 25
    • 33750459814 scopus 로고    scopus 로고
    • Optimized fat suppression sequence for cardiac imaging using stimulated echo mode (STEAM)
    • San Francisco, CA, USA. (abstract 524)
    • Fahmy AS, Osman NF. Optimized fat suppression sequence for cardiac imaging using stimulated echo mode (STEAM). In: Proceedings of the 8th Annual Meeting of SCMR. San Francisco, CA, USA. 2005 (abstract 524).
    • (2005) Proceedings of the 8th Annual Meeting of SCMR
    • Fahmy, A.S.1    Osman, N.F.2
  • 28
    • 0034956696 scopus 로고    scopus 로고
    • Characterization and reduction of the transient response in steady-state MR imaging
    • Hargreaves BA, Vasanawala SS, Pauly JM, Nishimura DG. Characterization and reduction of the transient response in steady-state MR imaging. Magn Reson Med 2001;46:149-158.
    • (2001) Magn Reson Med , vol.46 , pp. 149-158
    • Hargreaves, B.A.1    Vasanawala, S.S.2    Pauly, J.M.3    Nishimura, D.G.4
  • 29
    • 0036847421 scopus 로고    scopus 로고
    • Optimization of signal behavior in the transition to driven equilibrium in steady-state free precession sequences
    • Hennig J, Speck O, Scheffler K. Optimization of signal behavior in the transition to driven equilibrium in steady-state free precession sequences. Magn Reson Med 2002;48:801-809.
    • (2002) Magn Reson Med , vol.48 , pp. 801-809
    • Hennig, J.1    Speck, O.2    Scheffler, K.3
  • 30
    • 3543057674 scopus 로고    scopus 로고
    • Off-resonance effects in the transient response of SSFP sequences
    • Ganter C. Off-resonance effects in the transient response of SSFP sequences. Magn Reson Med 2004;52:368-375.
    • (2004) Magn Reson Med , vol.52 , pp. 368-375
    • Ganter, C.1
  • 31
    • 0037229176 scopus 로고    scopus 로고
    • Reduction of transient signal oscillations in True-FISP using a linear flip angle series magnetization preparation
    • Deshpande VS, Chung Y, Zhang Q, Shea SM, Li D. Reduction of transient signal oscillations in True-FISP using a linear flip angle series magnetization preparation. Magn Reson Med 2003;49:151-157.
    • (2003) Magn Reson Med , vol.49 , pp. 151-157
    • Deshpande, V.S.1    Chung, Y.2    Zhang, Q.3    Shea, S.M.4    Li, D.5
  • 32
    • 16444377441 scopus 로고    scopus 로고
    • Starter sequence for steady-state free precession imaging
    • Foxall DL, Starter sequence for steady-state free precession imaging. Magn Reson Med 2005;53:919-929.
    • (2005) Magn Reson Med , vol.53 , pp. 919-929
    • Foxall, D.L.1
  • 33
    • 0042494544 scopus 로고    scopus 로고
    • Simplified model and stabilization of SSFP sequences
    • Le Roux P. Simplified model and stabilization of SSFP sequences. J Magn Reson 2003;163:23-37.
    • (2003) J Magn Reson , vol.163 , pp. 23-37
    • Le Roux, P.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.