메뉴 건너뛰기




Volumn 24, Issue 5, 2006, Pages 1095-1100

Respiratory-triggered MRCP applying parallel acquisition techniques

Author keywords

Hepatobiliary imaging; MRCP; Parallel imaging; Quantitative and qualitative image comparison; Respiratory triggering

Indexed keywords

ADULT; AGED; ARTICLE; ARTIFACT; CONTRAST; ECHO PLANAR IMAGING; EVALUATION; FEMALE; HUMAN; IMAGE ANALYSIS; IMAGE DISPLAY; IMAGE PROCESSING; IMAGE QUALITY; IMAGING SYSTEM; MAGNETIC RESONANCE CHOLANGIOPANCREATOGRAPHY; MALE; PARENCHYMA; PRIORITY JOURNAL; QUALITATIVE ANALYSIS; QUANTITATIVE ANALYSIS; RESPIRATORY TRIGGERED MAGNETIC RESONANCE CHOLANGIOPANCREATOGRAPHY;

EID: 33750430304     PISSN: 10531807     EISSN: 15222586     Source Type: Journal    
DOI: 10.1002/jmri.20735     Document Type: Article
Times cited : (30)

References (19)
  • 1
    • 0036134271 scopus 로고    scopus 로고
    • Prospective assessment of magnetic resonance cholangiopancreatography for noninvasive imaging of the biliary tree
    • Taylor AC, Little AF, Hennessy OF, Banting SW, Smith PJ. Desmond PV. Prospective assessment of magnetic resonance cholangiopancreatography for noninvasive imaging of the biliary tree. Gastrointest Endosc 2002;55:17-22.
    • (2002) Gastrointest Endosc , vol.55 , pp. 17-22
    • Taylor, A.C.1    Little, A.F.2    Hennessy, O.F.3    Banting, S.W.4    Smith, P.J.5    Desmond, P.V.6
  • 2
    • 0842282850 scopus 로고    scopus 로고
    • The utility of MRCP in preoperative mapping of biliary anatomy in adult-to-adult living related liver transplant donors
    • Limanond P, Raman SS, Ghobrial RM, Busuttil RW, Lu DS. The utility of MRCP in preoperative mapping of biliary anatomy in adult-to-adult living related liver transplant donors. J Magn Reson Imaging 2004;19:209-215.
    • (2004) J Magn Reson Imaging , vol.19 , pp. 209-215
    • Limanond, P.1    Raman, S.S.2    Ghobrial, R.M.3    Busuttil, R.W.4    Lu, D.S.5
  • 3
    • 0034118803 scopus 로고    scopus 로고
    • Detection of choledocholithiasis with MR cholangiography: Comparison of three-dimensional fast spin-echo and single- and multisection half-fourier rapid acquisition with relaxation enhancement sequences
    • Soto JA, Barish MA, Alvarez O, Medina S. Detection of choledocholithiasis with MR cholangiography: comparison of three-dimensional fast spin-echo and single- and multisection half-fourier rapid acquisition with relaxation enhancement sequences. Radiology 2000;215:737-745.
    • (2000) Radiology , vol.215 , pp. 737-745
    • Soto, J.A.1    Barish, M.A.2    Alvarez, O.3    Medina, S.4
  • 4
    • 0029334408 scopus 로고
    • MR cholangiopancreatography: Comparison between two-dimensional fast spin-echo and three-dimensional gradient-echo pulse sequences
    • Reinhold C, Guibaud L, Genin G, Bret PM. MR cholangiopancreatography: comparison between two-dimensional fast spin-echo and three-dimensional gradient-echo pulse sequences. J Magn Reson Imaging 1995;5:379-384.
    • (1995) J Magn Reson Imaging , vol.5 , pp. 379-384
    • Reinhold, C.1    Guibaud, L.2    Genin, G.3    Bret, P.M.4
  • 5
    • 4344667528 scopus 로고    scopus 로고
    • High-resolution MR-imaging of the liver with T2-weighted sequences using integrated parallel imaging: Comparison of prospective motion correction and respiratory triggering
    • Zech CJ, Herrmann KA, Huber A, et al. High-resolution MR-imaging of the liver with T2-weighted sequences using integrated parallel imaging: comparison of prospective motion correction and respiratory triggering. J Magn Reson Imaging 2004;20:443-450.
    • (2004) J Magn Reson Imaging , vol.20 , pp. 443-450
    • Zech, C.J.1    Herrmann, K.A.2    Huber, A.3
  • 6
    • 27944503488 scopus 로고    scopus 로고
    • 2-weighted turbo spin-echo sequence with navigator triggered prospective acquisition correction
    • 2-weighted turbo spin-echo sequence with navigator triggered prospective acquisition correction. Magn Reson Imaging 2005;23:939-945.
    • (2005) Magn Reson Imaging , vol.23 , pp. 939-945
    • Asbach, P.1    Klessen, C.2    Kroencke, T.J.3
  • 7
    • 17844396526 scopus 로고    scopus 로고
    • Magnetic resonance imaging of the upper abdomen using a free-breathing T2-weighted turbo spin echo sequence with navigator triggered prospective acquisition correction
    • Klessen C, Asbach P, Kroencke TJ, et al. Magnetic resonance imaging of the upper abdomen using a free-breathing T2-weighted turbo spin echo sequence with navigator triggered prospective acquisition correction. J Magn Reson Imaging 2005;21:576-582.
    • (2005) J Magn Reson Imaging , vol.21 , pp. 576-582
    • Klessen, C.1    Asbach, P.2    Kroencke, T.J.3
  • 8
    • 0030982409 scopus 로고    scopus 로고
    • Simultaneous acquisition of spatial harmonics (SMASH): Fast imaging with radiofrequency coil arrays
    • Sodickson DK, Manning WJ. Simultaneous acquisition of spatial harmonics (SMASH): fast imaging with radiofrequency coil arrays. Magn Reson Med 1997;38:591-603.
    • (1997) Magn Reson Med , vol.38 , pp. 591-603
    • Sodickson, D.K.1    Manning, W.J.2
  • 9
    • 0033812663 scopus 로고    scopus 로고
    • Description of parallel imaging in MRI using multiple coils
    • Wang Yi. Description of parallel imaging in MRI using multiple coils. Magn Reson Med 2000;44:495-499.
    • (2000) Magn Reson Med , vol.44 , pp. 495-499
    • Wang, Yi.1
  • 10
    • 0141783642 scopus 로고    scopus 로고
    • High resolution contrast-enhanced 3D MR-angiography of renal arteries using parallel imaging (SENSE)
    • Walter C, Philippi G, Westerhausen R, Kooijman H, Hoffmann HG, Busch HP. High resolution contrast-enhanced 3D MR-angiography of renal arteries using parallel imaging (SENSE). Rofo 2003;175: 1244-1250.
    • (2003) Rofo , vol.175 , pp. 1244-1250
    • Walter, C.1    Philippi, G.2    Westerhausen, R.3    Kooijman, H.4    Hoffmann, H.G.5    Busch, H.P.6
  • 11
    • 0036263907 scopus 로고    scopus 로고
    • Generalized autocalibrating partially parallel acquisitions (GRAPPA)
    • Griswold MA, Jakob PM, Heidemann RM, et al. Generalized autocalibrating partially parallel acquisitions (GRAPPA). Magn Reson Med 2002;47:1202-1210.
    • (2002) Magn Reson Med , vol.47 , pp. 1202-1210
    • Griswold, M.A.1    Jakob, P.M.2    Heidemann, R.M.3
  • 12
    • 4344560587 scopus 로고    scopus 로고
    • Parallel acquisition techniques in cardiac cine magnetic resonance imaging using trueFISP sequences: Comparison of image quality and artefacts
    • Hunold P, Maderwald S, Ladd ME, et al. Parallel acquisition techniques in cardiac cine magnetic resonance imaging using trueFISP sequences: comparison of image quality and artefacts. J Magn Reson Imaging 2004;20:506-511.
    • (2004) J Magn Reson Imaging , vol.20 , pp. 506-511
    • Hunold, P.1    Maderwald, S.2    Ladd, M.E.3
  • 13
    • 15944423506 scopus 로고    scopus 로고
    • Parallel acquisition techniques for accelerated volumetric interpolated breath-hold examination magnetic resonance imaging of the upper abdomen: Assessment of image quality and lesion conspicuity
    • Vogt FM, Antoch G, Hunold P, et al. Parallel acquisition techniques for accelerated volumetric interpolated breath-hold examination magnetic resonance imaging of the upper abdomen: assessment of image quality and lesion conspicuity. J Magn Reson Imaging 2005;21:376-382.
    • (2005) J Magn Reson Imaging , vol.21 , pp. 376-382
    • Vogt, F.M.1    Antoch, G.2    Hunold, P.3
  • 14
    • 0032249265 scopus 로고    scopus 로고
    • Determination of contour clarity in contrast-enhanced MR angiography: Definition and clinical evaluation exemplified by ECG-triggered imaging of the thoracic aorta
    • German
    • Rodenwaldt J, Kopka L, Meyer HJ, Vosshenrich R, Funke M, Grabbe E. [Determination of contour clarity in contrast-enhanced MR angiography: definition and clinical evaluation exemplified by ECG-triggered imaging of the thoracic aorta.] Rofo 1998;169:616-621. [German]
    • (1998) Rofo , vol.169 , pp. 616-621
    • Rodenwaldt, J.1    Kopka, L.2    Meyer, H.J.3    Vosshenrich, R.4    Funke, M.5    Grabbe, E.6
  • 15
    • 33745693114 scopus 로고    scopus 로고
    • Influence of parallel imaging and other reconstruction techniques on the measurement of signal-to-noise ratios
    • Miami Beach, FL, USA
    • Dietrich O, Reeder SB, Reiser MF, Schoenberg SO. Influence of parallel imaging and other reconstruction techniques on the measurement of signal-to-noise ratios. In: Proceedings of the 13th Annual Meeting of the ISMRM. Miami Beach, FL, USA. 2005. p. 158.
    • (2005) Proceedings of the 13th Annual Meeting of the ISMRM , pp. 158
    • Dietrich, O.1    Reeder, S.B.2    Reiser, M.F.3    Schoenberg, S.O.4
  • 16
    • 4344600588 scopus 로고    scopus 로고
    • Two-dimensional parallel acquisition technique in 3D MR colonography
    • Steidle G, Schafer J, Schlemmer HP, Claussen CD, Schick F. Two-dimensional parallel acquisition technique in 3D MR colonography. Rofo 2004;176:1100-1105.
    • (2004) Rofo , vol.176 , pp. 1100-1105
    • Steidle, G.1    Schafer, J.2    Schlemmer, H.P.3    Claussen, C.D.4    Schick, F.5
  • 19
    • 26044475923 scopus 로고    scopus 로고
    • Pineapple juice labeled with gadolinium: A convenient oral contrast for magnetic resonance cholangiopancreatography
    • Coppens E, Metens T, Winant C, Matos C. Pineapple juice labeled with gadolinium: a convenient oral contrast for magnetic resonance cholangiopancreatography. Eur Radiol 2005;15:2122-2129.
    • (2005) Eur Radiol , vol.15 , pp. 2122-2129
    • Coppens, E.1    Metens, T.2    Winant, C.3    Matos, C.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.