메뉴 건너뛰기




Volumn 53, Issue 5, 2006, Pages 2759-2768

Volume-wise application of principal component analysis on masked dynamic PET data in sinogram domain

Author keywords

Masked dynamic data; Pixel wise noise prenormalization; Positron emission tomography (PET); Principal component analysis (PCA); Sinogram domain; Volume wise

Indexed keywords

MASKED DYNAMIC DATA; PIXEL WISE NOISE PRENORMALIZATION; SINOGRAM DOMAIN; VOLUME-WISE;

EID: 33750391184     PISSN: 00189499     EISSN: None     Source Type: Journal    
DOI: 10.1109/TNS.2006.878008     Document Type: Article
Times cited : (9)

References (26)
  • 1
    • 0020956774 scopus 로고
    • Graphicalevaluation of blood-to-brain transfer constants from multiple-time uptake data
    • C. S. Patlak, R. G. Blasberg, and J. D. Fenstermacher, "Graphicalevaluation of blood-to-brain transfer constants from multiple-time uptake data," J. Cereb. Blood Flow Metab., vol. 3, pp. 1-7, 1983.
    • (1983) J. Cereb. Blood Flow Metab. , vol.3 , pp. 1-7
    • Patlak, C.S.1    Blasberg, R.G.2    Fenstermacher, J.D.3
  • 3
    • 0033729522 scopus 로고    scopus 로고
    • Graphical analysis of PET data applied to reversible and irreversible tracers
    • J. Logan, "Graphical analysis of PET data applied to reversible and irreversible tracers," Nucl. Med. Biol., vol. 27, pp. 661-670, 2000.
    • (2000) Nucl. Med. Biol. , vol.27 , pp. 661-670
    • Logan, J.1
  • 4
    • 1642360794 scopus 로고    scopus 로고
    • Population approach improves parameter estimation of kinetic models from dynamic PET data
    • Mar.
    • A. Bertoldo, G. Sparacino, and C. Cobelli, "Population approach improves parameter estimation of kinetic models from dynamic PET data," IEEE Trans. Med. Imag., vol. 23, no. 3, pp. 297-306, Mar. 2004.
    • (2004) IEEE Trans. Med. Imag. , vol.23 , Issue.3 , pp. 297-306
    • Bertoldo, A.1    Sparacino, G.2    Cobelli, C.3
  • 5
    • 0024835021 scopus 로고
    • Strategy of multivariate image analysis (MIA)
    • K. Esbensen and P. Geladi, "Strategy of multivariate image analysis (MIA)," Chemometrics Intell. Lab. Syst., vol. 7, pp. 67-86, 1989.
    • (1989) Chemometrics Intell. Lab. Syst. , vol.7 , pp. 67-86
    • Esbensen, K.1    Geladi, P.2
  • 6
    • 0141990757 scopus 로고    scopus 로고
    • Different corticostriatal patterns of L-DOPA utilization in patients with untreated schizophrenia and patients treated with classical antipsychotics or clozapine
    • O. Gefvert, L. H. Lindstrom, N. Waters, S. Waters, A. Carlsson, and J. Tedroff, "Different corticostriatal patterns of L-DOPA utilization in patients with untreated schizophrenia and patients treated with classical antipsychotics or clozapine," Scand. J. Psychol., vol. 44, no. 3, pp. 289-92, 2003.
    • (2003) Scand. J. Psychol. , vol.44 , Issue.3 , pp. 289-292
    • Gefvert, O.1    Lindstrom, L.H.2    Waters, N.3    Waters, S.4    Carlsson, A.5    Tedroff, J.6
  • 7
    • 0028312612 scopus 로고
    • Principal component analysis of dynamic PET and gamma camera images: A methodology to visualize the signals in the presence of large noise
    • F. Pedersen, M. Bergström, E. Bengtsson, and E. Maripuu, "Principal component analysis of dynamic PET and gamma camera images: A methodology to visualize the signals in the presence of large noise," in 1993 IEEE Conf. Rec. Nucl. Sci. Symp. Med. Imag. Conf., 1993, vol. 3, pp. 1734-1738.
    • (1993) 1993 IEEE Conf. Rec. Nucl. Sci. Symp. Med. Imag. Conf. , vol.3 , pp. 1734-1738
    • Pedersen, F.1    Bergström, M.2    Bengtsson, E.3    Maripuu, E.4
  • 8
    • 0027973885 scopus 로고
    • Principal component analysis of dynamic positron emission tomography images
    • F. Pedersen, M. Bergström, E. Bengtsson, and B. Langström, "Principal component analysis of dynamic positron emission tomography images," Eur. J. Nucl. Med., vol. 21, pp. 1285-1292, 1994.
    • (1994) Eur. J. Nucl. Med. , vol.21 , pp. 1285-1292
    • Pedersen, F.1    Bergström, M.2    Bengtsson, E.3    Langström, B.4
  • 9
    • 84984382142 scopus 로고
    • An extended strategy for exploratory multivariate image analysis including noise considerations
    • F. Pedersen, E. Bengtsson, and B. Nordin, "An extended strategy for exploratory multivariate image analysis including noise considerations," J Chemometrics, vol. 9, pp. 389-409, 1995.
    • (1995) J Chemometrics , vol.9 , pp. 389-409
    • Pedersen, F.1    Bengtsson, E.2    Nordin, B.3
  • 10
    • 0027441566 scopus 로고
    • Functional connectivity: The principal-component analysis of large (PET) data sets
    • K. J. Friston, C. D. Frith, P. F. Liddle, and R. S. J. Frackowiak, "Functional connectivity: The principal-component analysis of large (PET) data sets," J. Cereb. Blood Flow Metab, vol. 13, pp. 5-14, 1993.
    • (1993) J. Cereb. Blood Flow Metab , vol.13 , pp. 5-14
    • Friston, K.J.1    Frith, C.D.2    Liddle, P.F.3    Frackowiak, R.S.J.4
  • 14
    • 0344672460 scopus 로고    scopus 로고
    • Experimental comparison of data transformation procedures for analysis of principal components
    • M. Šámal, M. Káný, H. Benali, W. Backfrieder, A. Todd-Pokropek, and H. Bergmann, "Experimental comparison of data transformation procedures for analysis of principal components," in Phys. Med. Biol., 1999, vol. 44, pp. 2821-34.
    • (1999) Phys. Med. Biol. , vol.44 , pp. 2821-2834
    • Šámal, M.1    Káný, M.2    Benali, H.3    Backfrieder, W.4    Todd-Pokropek, A.5    Bergmann, H.6
  • 16
    • 0032587718 scopus 로고    scopus 로고
    • Fast spatio-temporal image reconstruction for dynamic PET
    • Mar.
    • M. N. Wernick, E. J. Infusino, and M. Milosevic, "Fast spatio-temporal image reconstruction for dynamic PET," IEEE Trans. Med. Imag., vol. 18, pp. 185-195, Mar. 1999.
    • (1999) IEEE Trans. Med. Imag. , vol.18 , pp. 185-195
    • Wernick, M.N.1    Infusino, E.J.2    Milosevic, M.3
  • 17
    • 8344289248 scopus 로고    scopus 로고
    • Temporal processing of dynamic positron emission tomography via principal component analysis in the sinogram domain
    • Oct.
    • Z. Chen, B. J. Parker, D. D. Feng, and R. Fulton, "Temporal processing of dynamic positron emission tomography via principal component analysis in the sinogram domain," IEEE Trans. Nucl. Sci., vol. 51, no. 5, pp. 2612-2619, Oct. 2004.
    • (2004) IEEE Trans. Nucl. Sci. , vol.51 , Issue.5 , pp. 2612-2619
    • Chen, Z.1    Parker, B.J.2    Feng, D.D.3    Fulton, R.4
  • 20
    • 26444538705 scopus 로고
    • F. F. J. Knapp, C. Brihaye, and A. P. Callahan, H. N. Wagner, Z. Szabo, J. W. Buchanan, and W. B. Saunders, Eds. Philadelphia, PA: Saunders WB
    • F. F. J. Knapp, C. Brihaye, and A. P. Callahan, H. N. Wagner, Z. Szabo, J. W. Buchanan, and W. B. Saunders, Eds., Generators, Principles of Nuclear Medicine. Philadelphia, PA: Saunders WB, 1995, vol. 1, pp. 150-165.
    • (1995) Generators, Principles of Nuclear Medicine , vol.1 , pp. 150-165
  • 22
    • 0030082270 scopus 로고    scopus 로고
    • Adaptive segmented attenuation correction for whole-body PET imaging
    • M. Xu, P. D. Cutler, and W. K. Luk, "Adaptive segmented attenuation correction for whole-body PET imaging," IEEE Trans. Nucl. Sci., vol. 43, pp. 331-337, 1996.
    • (1996) IEEE Trans. Nucl. Sci. , vol.43 , pp. 331-337
    • Xu, M.1    Cutler, P.D.2    Luk, W.K.3
  • 23
    • 0018306059 scopus 로고
    • A threshold selection method from gray-level histograms
    • N. Otsu, "A threshold selection method from gray-level histograms," IEEE Trans. Syst. Man, Cybern., vol. 9, no. 1, pp. 377-393, 1979.
    • (1979) IEEE Trans. Syst. Man, Cybern. , vol.9 , Issue.1 , pp. 377-393
    • Otsu, N.1
  • 25
    • 26444586790 scopus 로고    scopus 로고
    • Non-isotropic noise correlation in PET data reconstructed by FBP but not by OSEM demonstrated using auto-correlation function
    • P. Razifar, M. Lubberink, H. Schneider, B. Langstrom, E. Bengtsson, and M. Bergstrom, "Non-isotropic noise correlation in PET data reconstructed by FBP but not by OSEM demonstrated using auto-correlation function," BMC Med. Imag., vol. 5, no. 1, 2005.
    • (2005) BMC Med. Imag. , vol.5 , Issue.1
    • Razifar, P.1    Lubberink, M.2    Schneider, H.3    Langstrom, B.4    Bengtsson, E.5    Bergstrom, M.6
  • 26
    • 26444534013 scopus 로고    scopus 로고
    • Noise correlation in PET, CT, SPECT and PET/CT data evaluated using autocorrelation function: A phantom study on data, reconstructed using FBP and OSEM
    • P. Razifar, M. Sandström, H. Schneider, B. Langstrom, E. Maripuu, E. Bengtsson, and M. Bergstrom, "Noise correlation in PET, CT, SPECT and PET/CT data evaluated using autocorrelation function: A phantom study on data, reconstructed using FBP and OSEM," BMC Med. Imag., vol. 5, no. 3, 2005.
    • (2005) BMC Med. Imag. , vol.5 , Issue.3
    • Razifar, P.1    Sandström, M.2    Schneider, H.3    Langstrom, B.4    Maripuu, E.5    Bengtsson, E.6    Bergstrom, M.7


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.