메뉴 건너뛰기




Volumn 53, Issue 5, 2006, Pages 2489-2494

RPC-PET: A new very high resolution PET technology

Author keywords

Gas detectors; Image resolution; Medical imaging; PET+; Positron sensitive particle detectors

Indexed keywords

ALGORITHMS; COMPUTER SIMULATION; GAS DETECTORS; IMAGE RECONSTRUCTION; MEDICAL IMAGING; POSITRON EMISSION TOMOGRAPHY; SENSITIVITY ANALYSIS;

EID: 33750386378     PISSN: 00189499     EISSN: None     Source Type: Journal    
DOI: 10.1109/TNS.2006.876005     Document Type: Article
Times cited : (50)

References (16)
  • 1
    • 0038510212 scopus 로고    scopus 로고
    • MicroPET II: Design, development and initial performance of an improved micropet scanner for small-animal imaging
    • Y.-C. Tai, "MicroPET II: Design, development and initial performance of an improved micropet scanner for small-animal imaging," Phys. Med. Biol., vol. 48, pp. 1519-1537, 2003.
    • (2003) Phys. Med. Biol. , vol.48 , pp. 1519-1537
    • Tai, Y.-C.1
  • 2
    • 0032316712 scopus 로고    scopus 로고
    • Yap-PET: First results of a small animal positron emission tomograph based on yap:Ce finger crystals
    • Dec.
    • A. del Guerra, G. Di Domenico, M. Scandola, and G. Zavattini, "Yap-PET: First results of a small animal positron emission tomograph based on yap:Ce finger crystals," IEEE Trans. Nucl. Sci., vol. 45, no. 6, pp. 3105-3108, Dec. 1998.
    • (1998) IEEE Trans. Nucl. Sci. , vol.45 , Issue.6 , pp. 3105-3108
    • Del Guerra, A.1    Di Domenico, G.2    Scandola, M.3    Zavattini, G.4
  • 3
    • 0041663428 scopus 로고    scopus 로고
    • Perspectives for positron emission tomography with RPCs
    • P. Fonte, "Perspectives for positron emission tomography with RPCs," Nucl. Instrum. Methods Phys. Res. A, vol. A508, pp. 88-93, 2003.
    • (2003) Nucl. Instrum. Methods Phys. Res. A , vol.A508 , pp. 88-93
    • Fonte, P.1
  • 6
    • 0042164420 scopus 로고    scopus 로고
    • Single-gap timing RPCs with bidimensional position-sensitive readout for very accurate TOF systems
    • P. Fonte, "Single-gap timing RPCs with bidimensional position-sensitive readout for very accurate TOF systems," Nucl. Instrum. Methods Phys. Res. A, vol. A508, pp. 70-74, 2003.
    • (2003) Nucl. Instrum. Methods Phys. Res. A , vol.A508 , pp. 70-74
    • Fonte, P.1
  • 7
    • 7044231695 scopus 로고    scopus 로고
    • An RPC-PET prototype with high spatial resolution
    • A. Blanco, "An RPC-PET prototype with high spatial resolution," Nucl. Instrum. Methods Phys. Res. A, vol. A533, pp. 139-143, 2004.
    • (2004) Nucl. Instrum. Methods Phys. Res. A , vol.A533 , pp. 139-143
    • Blanco, A.1
  • 8
    • 0033335619 scopus 로고    scopus 로고
    • A 3D HIDAC-PET camera with submillimeter resolution for imaging small animals
    • Jun.
    • A. P. Jeavons, R. A. Chandler, and C. A. R. Dettmar, "A 3D HIDAC-PET camera with submillimeter resolution for imaging small animals," IEEE Trans. Nucl. Sci., vol. 46, no. 3, pp. 468-473, Jun. 1999.
    • (1999) IEEE Trans. Nucl. Sci. , vol.46 , Issue.3 , pp. 468-473
    • Jeavons, A.P.1    Chandler, R.A.2    Dettmar, C.A.R.3
  • 9
    • 0001569189 scopus 로고
    • Empirical observation of resolution degradation in positron emission tomographs utilizing block detectors
    • W. W. Moses and S. E. Derenzo, "Empirical observation of resolution degradation in positron emission tomographs utilizing block detectors," J. Nucl. Med. vol. 34, p. 101, 1993.
    • (1993) J. Nucl. Med. , vol.34 , pp. 101
    • Moses, W.W.1    Derenzo, S.E.2
  • 10
    • 84939036393 scopus 로고
    • Mathematical removal of positron range blurring in high resolution tomography
    • Feb.
    • S. E. Derenzo, "Mathematical removal of positron range blurring in high resolution tomography," IEEE Trans. Nucl. Sci., vol. 33, no. 1, pp. 565-569, Feb. 1986.
    • (1986) IEEE Trans. Nucl. Sci. , vol.33 , Issue.1 , pp. 565-569
    • Derenzo, S.E.1
  • 11
    • 0033059817 scopus 로고    scopus 로고
    • Calculation of positron ranges and its effect on the fundamental limit of the positron emission tomography system spatial resolution
    • C. S. Levin and E. J. Hoffman, "Calculation of positron ranges and its effect on the fundamental limit of the positron emission tomography system spatial resolution," Phys. Med. Biol., vol. 44, pp. 781-799, 1999.
    • (1999) Phys. Med. Biol. , vol.44 , pp. 781-799
    • Levin, C.S.1    Hoffman, E.J.2
  • 12
    • 33750413191 scopus 로고    scopus 로고
    • EM reconstruction algorithm with resolution modeling applied to an RPC-PET prototype
    • submitted to publication to IEEE Trans. Nucl. Sci.
    • L. Fazendeiro, "EM reconstruction algorithm with resolution modeling applied to an RPC-PET prototype," in IEEE Med. Image Conf. 2004 Proc., submitted to publication to IEEE Trans. Nucl. Sci.
    • IEEE Med. Image Conf. 2004 Proc.
    • Fazendeiro, L.1
  • 14
    • 3242789549 scopus 로고    scopus 로고
    • Optimization and performance evaluation of the microPET II scanner for in vivo small-animal imaging
    • Y. Yang, "Optimization and performance evaluation of the microPET II scanner for in vivo small-animal imaging," Phys. Med. Biol., vol. 49, pp. 2527-2545, 2004.
    • (2004) Phys. Med. Biol. , vol.49 , pp. 2527-2545
    • Yang, Y.1
  • 15
    • 0037147880 scopus 로고    scopus 로고
    • Characterization of the ferrera animal PET scanner
    • G. Di Domenico, "Characterization of the ferrera animal PET scanner," Nucl. Instrum. Methods Phys. Res. A, vol. A477, pp. 505-508, 2002.
    • (2002) Nucl. Instrum. Methods Phys. Res. A , vol.A477 , pp. 505-508
    • Di Domenico, G.1
  • 16
    • 33750426886 scopus 로고    scopus 로고
    • [Online]
    • [Online]. Available: http://www.oxpos.co.uk/


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.