-
1
-
-
0030725989
-
Implementation of quantitative perfusion imaging techniques for functional brain mapping using pulsed arterial spin labeling
-
Wong E.C., Buxton R.B., and Frank L.R. Implementation of quantitative perfusion imaging techniques for functional brain mapping using pulsed arterial spin labeling. NMR Biomed 10 4-5 (1997) 237-249
-
(1997)
NMR Biomed
, vol.10
, Issue.4-5
, pp. 237-249
-
-
Wong, E.C.1
Buxton, R.B.2
Frank, L.R.3
-
2
-
-
0029151256
-
Quantification of relative cerebral blood flow change by flow-sensitive alternating inversion recovery (FAIR) technique: application to functional mapping
-
Kim S.G. Quantification of relative cerebral blood flow change by flow-sensitive alternating inversion recovery (FAIR) technique: application to functional mapping. Magn Reson Med 34 3 (1995) 293-301
-
(1995)
Magn Reson Med
, vol.34
, Issue.3
, pp. 293-301
-
-
Kim, S.G.1
-
4
-
-
0030883659
-
Slice profile effects in adiabatic inversion: application to multislice perfusion imaging
-
Frank L.R., Wong E.C., and Buxton R.B. Slice profile effects in adiabatic inversion: application to multislice perfusion imaging. Magn Reson Med 38 4 (1997) 558-564
-
(1997)
Magn Reson Med
, vol.38
, Issue.4
, pp. 558-564
-
-
Frank, L.R.1
Wong, E.C.2
Buxton, R.B.3
-
5
-
-
0034958204
-
Theoretical analysis of the effect of imperfect slice profiles on tagging schemes for pulsed arterial spin labeling MRI
-
Keilholz-George S.D., Knight-Scott J., and Berr S.S. Theoretical analysis of the effect of imperfect slice profiles on tagging schemes for pulsed arterial spin labeling MRI. Magn Reson Med 46 1 (2001) 141-148
-
(2001)
Magn Reson Med
, vol.46
, Issue.1
, pp. 141-148
-
-
Keilholz-George, S.D.1
Knight-Scott, J.2
Berr, S.S.3
-
6
-
-
0032749944
-
Multislice perfusion imaging in human brain using the C-FOCI inversion pulse: comparison with hyperbolic secant
-
Yongbi M.N., Yang Y., Frank J.A., and Duyn J.H. Multislice perfusion imaging in human brain using the C-FOCI inversion pulse: comparison with hyperbolic secant. Magn Reson Med 42 6 (1999) 1098-1105
-
(1999)
Magn Reson Med
, vol.42
, Issue.6
, pp. 1098-1105
-
-
Yongbi, M.N.1
Yang, Y.2
Frank, J.A.3
Duyn, J.H.4
-
8
-
-
33750329370
-
The effects of the order of saturation and inversion in pulsed arterial spin labeling
-
Sidaros K., Andersen I.K., Liu T.T., Wong E.C., and Buxton R.B. The effects of the order of saturation and inversion in pulsed arterial spin labeling. Proceedings of the 11th Annual Meeting of the International Society of Magnetic Resonance in Medicine (2003) 2214
-
(2003)
Proceedings of the 11th Annual Meeting of the International Society of Magnetic Resonance in Medicine
, pp. 2214
-
-
Sidaros, K.1
Andersen, I.K.2
Liu, T.T.3
Wong, E.C.4
Buxton, R.B.5
-
9
-
-
48549111126
-
Highly selective pi/2 and pi pulse generation
-
Silver M.S., Joseph R.I., and Hoult D.I. Highly selective pi/2 and pi pulse generation. J Magn Reson 59 (1984) 347-351
-
(1984)
J Magn Reson
, Issue.59
, pp. 347-351
-
-
Silver, M.S.1
Joseph, R.I.2
Hoult, D.I.3
-
10
-
-
0028081569
-
An integrated program for amplitude-modulated RF pulse generation and re-mapping with shaped gradients
-
Matson G.B. An integrated program for amplitude-modulated RF pulse generation and re-mapping with shaped gradients. Magn Reson Imaging 12 8 (1994) 1205-1225
-
(1994)
Magn Reson Imaging
, vol.12
, Issue.8
, pp. 1205-1225
-
-
Matson, G.B.1
-
11
-
-
33750311681
-
Presaturation efficiency in pulsed arterial spin labeling in the presence of B1 inhomogeneities
-
Sidaros K., Andersen I.K., Liu T.T., Wong E.C., and Buxton R.B. Presaturation efficiency in pulsed arterial spin labeling in the presence of B1 inhomogeneities. Proceedings Eleventh ISMRM (2003) 2214
-
(2003)
Proceedings Eleventh ISMRM
, pp. 2214
-
-
Sidaros, K.1
Andersen, I.K.2
Liu, T.T.3
Wong, E.C.4
Buxton, R.B.5
-
12
-
-
0031966050
-
Quantitative imaging of perfusion using a single subtraction (QUIPSS and QUIPSS II)
-
Wong E.C., Buxton R.B., and Frank L.R. Quantitative imaging of perfusion using a single subtraction (QUIPSS and QUIPSS II). Magn Reson Med 39 5 (1998) 702-708
-
(1998)
Magn Reson Med
, vol.39
, Issue.5
, pp. 702-708
-
-
Wong, E.C.1
Buxton, R.B.2
Frank, L.R.3
-
13
-
-
33750339653
-
Improved SNR in perfusion fMRI by offset correction
-
Sidaros K., Liu T.T., Lund T.E., Wong E.C., and Buxton R.B. Improved SNR in perfusion fMRI by offset correction. Proceedings of the 10th Annual Meeting of the International Society of Magnetic Resonance in Medicine (2002) 624
-
(2002)
Proceedings of the 10th Annual Meeting of the International Society of Magnetic Resonance in Medicine
, pp. 624
-
-
Sidaros, K.1
Liu, T.T.2
Lund, T.E.3
Wong, E.C.4
Buxton, R.B.5
-
14
-
-
0029782594
-
Frequency offset corrected inversion (FOCI) pulses for use in localized spectroscopy
-
Ordidge R.J., Wylezinska M., Hugg J.W., Butterworth E., and Franconi F. Frequency offset corrected inversion (FOCI) pulses for use in localized spectroscopy. Magn Reson Med 36 4 (1996) 562-566
-
(1996)
Magn Reson Med
, vol.36
, Issue.4
, pp. 562-566
-
-
Ordidge, R.J.1
Wylezinska, M.2
Hugg, J.W.3
Butterworth, E.4
Franconi, F.5
-
15
-
-
33750326124
-
Synthesis of soft pulses with specified frequency responses
-
Shinnar M., Boliger L., and Leigh J.S. Synthesis of soft pulses with specified frequency responses. Proceedings 7th SMRM (1988) 1040
-
(1988)
Proceedings 7th SMRM
, pp. 1040
-
-
Shinnar, M.1
Boliger, L.2
Leigh, J.S.3
-
16
-
-
0042206005
-
Exact synthesis of radio frequency waveforms
-
Le Roux P. Exact synthesis of radio frequency waveforms. Proceedings 7th SMRM (1988) 1049
-
(1988)
Proceedings 7th SMRM
, pp. 1049
-
-
Le Roux, P.1
|