메뉴 건너뛰기




Volumn 11, Issue 2, 2006, Pages 137-148

Volar Plating of Distal Radius Fractures

Author keywords

[No Author keywords available]

Indexed keywords

ARTHROSCOPY; BIOMECHANICS; BONE GRAFT; BONE PLATE; COMMINUTED FRACTURE; DISEASE SEVERITY; EQUIPMENT DESIGN; FOLLOW UP; FRAGILITY FRACTURE; HUMAN; IMPLANT; JOINT FRACTURE; LIGAMENT INJURY; ORTHOPEDIC SURGERY; OSTEOSYNTHESIS; PLATE FIXATION; POSTOPERATIVE CARE; RADIUS FRACTURE; REVIEW; SPLINTING; SURGICAL APPROACH; SURGICAL TECHNIQUE; TREATMENT INDICATION; WEIGHT BEARING; WIRE FIXATION; WOUND CLOSURE;

EID: 33750315402     PISSN: 10823131     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.ahc.2006.07.001     Document Type: Review
Times cited : (2)

References (35)
  • 1
    • 0027518565 scopus 로고
    • Severe fractures of the distal radius: effect of amount and duration of external fixator distraction on outcome
    • Kaempffe F.A., Wheeler D.R., Peimer C.A., et al. Severe fractures of the distal radius: effect of amount and duration of external fixator distraction on outcome. J Hand Surg 18 1 (1993) 33-41
    • (1993) J Hand Surg , vol.18 , Issue.1 , pp. 33-41
    • Kaempffe, F.A.1    Wheeler, D.R.2    Peimer, C.A.3
  • 2
    • 0031414105 scopus 로고    scopus 로고
    • Correlation of wrist ligamentotaxis with carpal distraction: implications for external fixation
    • Loebig T.G., Badia A., Anderson D.D., et al. Correlation of wrist ligamentotaxis with carpal distraction: implications for external fixation. J Hand Surg [Am] 22 6 (1997) 1052-1056
    • (1997) J Hand Surg [Am] , vol.22 , Issue.6 , pp. 1052-1056
    • Loebig, T.G.1    Badia, A.2    Anderson, D.D.3
  • 3
    • 0033744154 scopus 로고    scopus 로고
    • External fixation for distal radius fractures: effect of distraction on outcome
    • Kaempffe F.A., and Walker K.M. External fixation for distal radius fractures: effect of distraction on outcome. Clin Orthop Relat Res 380 (2000) 220-225
    • (2000) Clin Orthop Relat Res , Issue.380 , pp. 220-225
    • Kaempffe, F.A.1    Walker, K.M.2
  • 4
    • 0028849835 scopus 로고
    • Design and biomechanics of a plate for the distal radius
    • Gesensway D., Putnam M.D., Mente P.L., et al. Design and biomechanics of a plate for the distal radius. J Hand Surg 20 6 (1995) 1021-1027
    • (1995) J Hand Surg , vol.20 , Issue.6 , pp. 1021-1027
    • Gesensway, D.1    Putnam, M.D.2    Mente, P.L.3
  • 5
    • 0032467256 scopus 로고    scopus 로고
    • Open reduction and internal fixation of unstable distal radius fractures with a low-profile plate: a multi-center study of 73 fractures
    • Carter P.R., Frederick H.A., and Laseter G.F. Open reduction and internal fixation of unstable distal radius fractures with a low-profile plate: a multi-center study of 73 fractures. J Hand Surg 23 2 (1998) 300-307
    • (1998) J Hand Surg , vol.23 , Issue.2 , pp. 300-307
    • Carter, P.R.1    Frederick, H.A.2    Laseter, G.F.3
  • 6
    • 0034302091 scopus 로고    scopus 로고
    • Extensor tendon rupture secondary to the AO/ASIF titanium distal radius plate without associated plate failure: a case report
    • Lowry K.J., Gainor B.J., and Hoskins J.S. Extensor tendon rupture secondary to the AO/ASIF titanium distal radius plate without associated plate failure: a case report. Am J Orthop 29 10 (2000) 789-791
    • (2000) Am J Orthop , vol.29 , Issue.10 , pp. 789-791
    • Lowry, K.J.1    Gainor, B.J.2    Hoskins, J.S.3
  • 7
    • 0030928604 scopus 로고    scopus 로고
    • Prospective multi-center trial of a plate for dorsal fixation of distal radius fractures
    • Ring D., Jupiter J.B., Brennwald J., et al. Prospective multi-center trial of a plate for dorsal fixation of distal radius fractures. J Hand Surg 22 5 (1997) 777-784
    • (1997) J Hand Surg , vol.22 , Issue.5 , pp. 777-784
    • Ring, D.1    Jupiter, J.B.2    Brennwald, J.3
  • 8
    • 0034821880 scopus 로고    scopus 로고
    • Volar approach to dorsal displaced fractures of the radius
    • Henry M.H., Griggs S.M., Levaro F., et al. Volar approach to dorsal displaced fractures of the radius. Tech Hand Up Extrem Surg 5 (2001) 31-41
    • (2001) Tech Hand Up Extrem Surg , vol.5 , pp. 31-41
    • Henry, M.H.1    Griggs, S.M.2    Levaro, F.3
  • 9
    • 0034578071 scopus 로고    scopus 로고
    • The treatment of unstable distal radius fractures with volar fixation
    • Orbay J.L. The treatment of unstable distal radius fractures with volar fixation. Hand Surg 5 2 (2000) 103-112
    • (2000) Hand Surg , vol.5 , Issue.2 , pp. 103-112
    • Orbay, J.L.1
  • 10
    • 0035210792 scopus 로고    scopus 로고
    • The extended flexor carpi radialis approach: a new perspective for the distal radius fracture
    • Orbay J.L., Badia A., and Indriago I.R. The extended flexor carpi radialis approach: a new perspective for the distal radius fracture. Tech Hand Up Extrem Surg 5 (2001) 204-211
    • (2001) Tech Hand Up Extrem Surg , vol.5 , pp. 204-211
    • Orbay, J.L.1    Badia, A.2    Indriago, I.R.3
  • 11
    • 4644222787 scopus 로고    scopus 로고
    • Biomechanics of locked plates and screws
    • Egol K.A., Kubiak E.N., Fulkerson E., et al. Biomechanics of locked plates and screws. J Orthop Trauma 18 8 (2004) 488-493
    • (2004) J Orthop Trauma , vol.18 , Issue.8 , pp. 488-493
    • Egol, K.A.1    Kubiak, E.N.2    Fulkerson, E.3
  • 12
    • 0038627493 scopus 로고    scopus 로고
    • Palmar plate fixation of AO type C2 fracture of distal radius using a locking compression plate-a biomechanical study in a cadaveric model
    • Leung F., Zhu L., Ho H., et al. Palmar plate fixation of AO type C2 fracture of distal radius using a locking compression plate-a biomechanical study in a cadaveric model. J Hand Surg 28 3 (2003) 263-266
    • (2003) J Hand Surg , vol.28 , Issue.3 , pp. 263-266
    • Leung, F.1    Zhu, L.2    Ho, H.3
  • 13
    • 0037244095 scopus 로고    scopus 로고
    • Comparison of different distal radius dorsal and volar fracture fixation plates: a biomechanical study
    • Osada D., Viegas S.F., Shah M.A., et al. Comparison of different distal radius dorsal and volar fracture fixation plates: a biomechanical study. J Hand Surg 28 1 (2003) 94-104
    • (2003) J Hand Surg , vol.28 , Issue.1 , pp. 94-104
    • Osada, D.1    Viegas, S.F.2    Shah, M.A.3
  • 14
    • 16244400503 scopus 로고    scopus 로고
    • A biomechanical comparison of a dorsal 3.5 mm T plate and a volar fixed-angle plate in a model of dorsally unstable distal radius fractures
    • Liporace F.A., Gupta S., Jeong G.K., et al. A biomechanical comparison of a dorsal 3.5 mm T plate and a volar fixed-angle plate in a model of dorsally unstable distal radius fractures. J Orthop Trauma 19 3 (2005) 187-191
    • (2005) J Orthop Trauma , vol.19 , Issue.3 , pp. 187-191
    • Liporace, F.A.1    Gupta, S.2    Jeong, G.K.3
  • 15
    • 22544486562 scopus 로고    scopus 로고
    • Locking versus nonlocking T plates for dorsal and volar fixation of dorsally comminuted distal radius fractures: a biomechanical study
    • Trease C., McIff T., and Toby E.B. Locking versus nonlocking T plates for dorsal and volar fixation of dorsally comminuted distal radius fractures: a biomechanical study. J Hand Surg [Am ] 30 4 (2005) 756-763
    • (2005) J Hand Surg [Am ] , vol.30 , Issue.4 , pp. 756-763
    • Trease, C.1    McIff, T.2    Toby, E.B.3
  • 16
    • 0023257432 scopus 로고
    • A biomechanical study of distal radial fractures
    • Short W.H., Palmer A.K., Werner F.W., et al. A biomechanical study of distal radial fractures. J Hand Surg 12 4 (1987) 529-534
    • (1987) J Hand Surg , vol.12 , Issue.4 , pp. 529-534
    • Short, W.H.1    Palmer, A.K.2    Werner, F.W.3
  • 17
    • 0026735942 scopus 로고
    • Force transmission through the distal ulna: effect of ulnar variance, lunate fossa angulation, and radial and palmar tilt of the distal radius
    • Werner F.W., Palmer A.K., Fortino M.D., et al. Force transmission through the distal ulna: effect of ulnar variance, lunate fossa angulation, and radial and palmar tilt of the distal radius. J Hand Surg 17 3 (1992) 423-428
    • (1992) J Hand Surg , vol.17 , Issue.3 , pp. 423-428
    • Werner, F.W.1    Palmer, A.K.2    Fortino, M.D.3
  • 18
    • 4544359393 scopus 로고    scopus 로고
    • Loss of fixation of the volar lunate facet fragment in fractures of the distal part of the radius
    • Harness N.G., Jupiter J.B., Orbay J.L., et al. Loss of fixation of the volar lunate facet fragment in fractures of the distal part of the radius. J Bone Joint Surg Am 86-A 9 (2004) 1900-1908
    • (2004) J Bone Joint Surg Am , vol.86 -A , Issue.9 , pp. 1900-1908
    • Harness, N.G.1    Jupiter, J.B.2    Orbay, J.L.3
  • 19
    • 4644221548 scopus 로고    scopus 로고
    • Volar fixed-angle fixation of distal radius fractures: the DVR plate
    • Orbay J., Badia A., Khoury R.K., et al. Volar fixed-angle fixation of distal radius fractures: the DVR plate. Tech Hand Up Extrem Surg 8 3 (2004) 142-148
    • (2004) Tech Hand Up Extrem Surg , vol.8 , Issue.3 , pp. 142-148
    • Orbay, J.1    Badia, A.2    Khoury, R.K.3
  • 20
    • 3042534759 scopus 로고    scopus 로고
    • Corrective osteotomy of the distal radius through volar approach
    • Prommersberger K.J., and Lanz U.B. Corrective osteotomy of the distal radius through volar approach. Tech Hand Up Extrem Surg 8 2 (2004) 70-77
    • (2004) Tech Hand Up Extrem Surg , vol.8 , Issue.2 , pp. 70-77
    • Prommersberger, K.J.1    Lanz, U.B.2
  • 21
    • 0030010872 scopus 로고    scopus 로고
    • Fractures of the distal end of the radius treated by internal fixation and early function. A preliminary report of 20 cases
    • Rikli D.A., and Regazzoni P. Fractures of the distal end of the radius treated by internal fixation and early function. A preliminary report of 20 cases. J Bone Joint Surg Br 78 4 (1996) 588-592
    • (1996) J Bone Joint Surg Br , vol.78 , Issue.4 , pp. 588-592
    • Rikli, D.A.1    Regazzoni, P.2
  • 22
    • 0001438511 scopus 로고    scopus 로고
    • Immediate internal fixation and motion of comminuted distal radius fractures using a new fragment specific fixation system
    • Medoff R.J., and Kopylov P. Immediate internal fixation and motion of comminuted distal radius fractures using a new fragment specific fixation system. Orthopaedic Transactions 22 1 (1998) 165
    • (1998) Orthopaedic Transactions , vol.22 , Issue.1 , pp. 165
    • Medoff, R.J.1    Kopylov, P.2
  • 23
    • 0004911688 scopus 로고    scopus 로고
    • Open reduction and immediate motion of intra articular distal radius fractures with a fragment specific fixation system
    • Medoff R.J., and Kopylov P. Open reduction and immediate motion of intra articular distal radius fractures with a fragment specific fixation system. Archives of the American Academy of Orthopaedic Surgeons 2 (1999) 53-61
    • (1999) Archives of the American Academy of Orthopaedic Surgeons , Issue.2 , pp. 53-61
    • Medoff, R.J.1    Kopylov, P.2
  • 24
    • 0036130725 scopus 로고    scopus 로고
    • Volar fixation for dorsally displaced fractures of the distal radius: a preliminary report
    • Orbay J.L., and Fernandez D.L. Volar fixation for dorsally displaced fractures of the distal radius: a preliminary report. J Hand Surg 27 2 (2002) 205-215
    • (2002) J Hand Surg , vol.27 , Issue.2 , pp. 205-215
    • Orbay, J.L.1    Fernandez, D.L.2
  • 25
    • 0036241905 scopus 로고    scopus 로고
    • Palmar plating for dorsally displaced fractures of the distal radius
    • Kamano M., Honda Y., Kazuki K., et al. Palmar plating for dorsally displaced fractures of the distal radius. Clin Orthop Relat Res 397 (2002) 403-408
    • (2002) Clin Orthop Relat Res , vol.397 , pp. 403-408
    • Kamano, M.1    Honda, Y.2    Kazuki, K.3
  • 26
    • 22544439956 scopus 로고    scopus 로고
    • Palmar plating system for Colles' fractures-a preliminary report
    • Kamano M., Koshimune M., Toyama M., et al. Palmar plating system for Colles' fractures-a preliminary report. J Hand Surg [Am] 30 4 (2005) 750-755
    • (2005) J Hand Surg [Am] , vol.30 , Issue.4 , pp. 750-755
    • Kamano, M.1    Koshimune, M.2    Toyama, M.3
  • 27
    • 1642517070 scopus 로고    scopus 로고
    • Palmar plating with the locking compression plate for dorsally displaced fractures of the distal radius-first clinical experiences
    • Schutz M., Kolbeck S., Spranger A., et al. Palmar plating with the locking compression plate for dorsally displaced fractures of the distal radius-first clinical experiences. Zentralbl Chir 128 12 (2003) 997-1002
    • (2003) Zentralbl Chir , vol.128 , Issue.12 , pp. 997-1002
    • Schutz, M.1    Kolbeck, S.2    Spranger, A.3
  • 28
    • 0037573333 scopus 로고    scopus 로고
    • Results after palmar plate-osteosynthesis with angularly stable T plate in 100 distal radius fractures: a prospective study
    • Sakhaii M., Groenewold U., Klonz A., et al. Results after palmar plate-osteosynthesis with angularly stable T plate in 100 distal radius fractures: a prospective study. Unfallchirurg 106 4 (2003) 272-280
    • (2003) Unfallchirurg , vol.106 , Issue.4 , pp. 272-280
    • Sakhaii, M.1    Groenewold, U.2    Klonz, A.3
  • 29
    • 21744461769 scopus 로고    scopus 로고
    • Volar plating of dorsally comminuted fractures of the distal radius: a 6-year study
    • Douthit J.D. Volar plating of dorsally comminuted fractures of the distal radius: a 6-year study. Am J Orthop 34 3 (2005) 140-147
    • (2005) Am J Orthop , vol.34 , Issue.3 , pp. 140-147
    • Douthit, J.D.1
  • 30
    • 23344449087 scopus 로고    scopus 로고
    • Palmar locking plate for treatment of unstable dorsal dislocated distal radius fractures
    • Arora R., Lutz M., Fritz D., et al. Palmar locking plate for treatment of unstable dorsal dislocated distal radius fractures. Arch Orthop Trauma Surg 125 6 (2005) 399-404
    • (2005) Arch Orthop Trauma Surg , vol.125 , Issue.6 , pp. 399-404
    • Arora, R.1    Lutz, M.2    Fritz, D.3
  • 31
    • 0742270693 scopus 로고    scopus 로고
    • Volar fixed-angle plate fixation for unstable distal radius fractures in the elderly patient
    • [Am]
    • Orbay J.L., and Fernandez D.L. Volar fixed-angle plate fixation for unstable distal radius fractures in the elderly patient. J Hand Surg 29 1 (2004) 96-102 [Am]
    • (2004) J Hand Surg , vol.29 , Issue.1 , pp. 96-102
    • Orbay, J.L.1    Fernandez, D.L.2
  • 32
    • 1442351200 scopus 로고    scopus 로고
    • Results of palmar T plate osteosynthesis in unstable fractures of the distal radius
    • Dumont C., Fuchs M., Folwaczny E.K., et al. Results of palmar T plate osteosynthesis in unstable fractures of the distal radius. Chirurg 74 9 (2003) 827-833
    • (2003) Chirurg , vol.74 , Issue.9 , pp. 827-833
    • Dumont, C.1    Fuchs, M.2    Folwaczny, E.K.3
  • 33
    • 3142704175 scopus 로고    scopus 로고
    • Palmar fixed-angle plating systems for unstable distal radius fracture
    • Krimmer H., Pessenlehner C., Hasselbacher K., et al. Palmar fixed-angle plating systems for unstable distal radius fracture. Unfallchirurg 107 6 (2004) 460-467
    • (2004) Unfallchirurg , vol.107 , Issue.6 , pp. 460-467
    • Krimmer, H.1    Pessenlehner, C.2    Hasselbacher, K.3
  • 34
    • 33646840103 scopus 로고    scopus 로고
    • Current concepts in volar fixed-angle fixation of unstable distal radius fractures
    • Orbay J.L., and Touhami A. Current concepts in volar fixed-angle fixation of unstable distal radius fractures. Clin Orthop Relat Res 445 (2006) 58-67
    • (2006) Clin Orthop Relat Res , vol.445 , pp. 58-67
    • Orbay, J.L.1    Touhami, A.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.