Volumn 13, Issue 11, 2006, Pages 1317-1326

Comparison of LCD and CRT Displays Based on Efficacy for Digital Mammography

Author keywords

cathode ray tube; CRT; Digital mammography; LCD; liquid crystal display; observer performance; soft copy display

Indexed keywords

ARTICLE; BREAST CALCIFICATION; BREAST CANCER; BREAST EXAMINATION; BREAST TUMOR; CATHODE RAY OSCILLOSCOPE; CLINICAL EFFECTIVENESS; CLINICAL EXAMINATION; CLINICAL OBSERVATION; DATA ANALYSIS; DIAGNOSTIC ACCURACY; DIAGNOSTIC VALUE; DIFFERENTIAL DIAGNOSIS; DIGITAL IMAGING; DISEASE CLASSIFICATION; IMAGE DISPLAY; IMAGE QUALITY; INTERMETHOD COMPARISON; LIQUID CRYSTAL DISPLAY; MAMMOGRAPHY; PERSONAL EXPERIENCE; PRIORITY JOURNAL; RADIODIAGNOSIS; RADIOLOGIST; SIMULATION; STATISTICAL SIGNIFICANCE;

EID: 33750285479     PISSN: 10766332     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.acra.2006.07.017     Document Type: Article
Times cited : (19)

References (31)
  • 1
    • 27344458270 scopus 로고    scopus 로고
    • Diagnostic performance of digital versus film mammography for breast-cancer screening
    • Pisano E.D., Gatsonis C., Hendrick E., et al. Diagnostic performance of digital versus film mammography for breast-cancer screening. N Engl J Med 353 (2005) 1773-1783
    • (2005) N Engl J Med , vol.353 , pp. 1773-1783
    • Pisano, E.D.1    Gatsonis, C.2    Hendrick, E.3
  • 2
    • 31844450155 scopus 로고    scopus 로고
    • Resolution and noise measurements of five CRT and LCD medical displays
    • Saunders R.S., and Samei E. Resolution and noise measurements of five CRT and LCD medical displays. Med Phys 33 (2006) 308-319
    • (2006) Med Phys , vol.33 , pp. 308-319
    • Saunders, R.S.1    Samei, E.2
  • 3
    • 14644435701 scopus 로고    scopus 로고
    • Physical characterization of a prototype selenium-based full field digital mammography detector
    • Saunders Jr. R.S., Samei E., Jesneck J.L., et al. Physical characterization of a prototype selenium-based full field digital mammography detector. Med Phys 32 (2005) 588-599
    • (2005) Med Phys , vol.32 , pp. 588-599
    • Saunders Jr., R.S.1    Samei, E.2    Jesneck, J.L.3
  • 4
    • 0042625070 scopus 로고    scopus 로고
    • Improving visualization of digital mammograms on the CRT display system
    • Fan J., Dallas W.J., Roehrig H., et al. Improving visualization of digital mammograms on the CRT display system. Proc SPIE 5029 (2003) 746-753
    • (2003) Proc SPIE , vol.5029 , pp. 746-753
    • Fan, J.1    Dallas, W.J.2    Roehrig, H.3
  • 5
    • 0032589024 scopus 로고    scopus 로고
    • Why and how is soft copy reading possible in clinical practice?
    • Mertelmeier T. Why and how is soft copy reading possible in clinical practice?. J Dig Imaging 12 (1999) 3-11
    • (1999) J Dig Imaging , vol.12 , pp. 3-11
    • Mertelmeier, T.1
  • 6
    • 0029463772 scopus 로고
    • Display of medical images on CRT soft-copy displays: a tutorial
    • Muka E., Blume H.R., and Daly S.J. Display of medical images on CRT soft-copy displays: a tutorial. Proc SPIE 2431 (1995) 341-359
    • (1995) Proc SPIE , vol.2431 , pp. 341-359
    • Muka, E.1    Blume, H.R.2    Daly, S.J.3
  • 7
    • 0033747239 scopus 로고    scopus 로고
    • Factors affecting CRT display performance: specifying what works
    • Compton K.D. Factors affecting CRT display performance: specifying what works. Proc SPIE 3976 (2000) 412-423
    • (2000) Proc SPIE , vol.3976 , pp. 412-423
    • Compton, K.D.1
  • 8
    • 0034859322 scopus 로고    scopus 로고
    • A method for in-field evaluation of the modulation transfer function of electronic display devices
    • Samei E., and Flynn M.J. A method for in-field evaluation of the modulation transfer function of electronic display devices. Proc SPIE 4319 (2001) 599-607
    • (2001) Proc SPIE , vol.4319 , pp. 599-607
    • Samei, E.1    Flynn, M.J.2
  • 9
    • 0036057279 scopus 로고    scopus 로고
    • Characterization of high-resolution liquid crystal displays for medical images
    • Blume H.R., Steven P.M., Cobb M.E., et al. Characterization of high-resolution liquid crystal displays for medical images. Proc SPIE 4681 (2002) 271-292
    • (2002) Proc SPIE , vol.4681 , pp. 271-292
    • Blume, H.R.1    Steven, P.M.2    Cobb, M.E.3
  • 10
    • 1942452289 scopus 로고    scopus 로고
    • Noise in flat-panel displays with subpixel structure
    • Badano A., Gagne R.M., Jennings R.J., et al. Noise in flat-panel displays with subpixel structure. Med Phys 31 (2004) 715-723
    • (2004) Med Phys , vol.31 , pp. 715-723
    • Badano, A.1    Gagne, R.M.2    Jennings, R.J.3
  • 11
    • 6344272640 scopus 로고    scopus 로고
    • Luminance and contrast performance of liquid crystal displays for mammographic applications
    • Samei E., and Wright S.L. Luminance and contrast performance of liquid crystal displays for mammographic applications. Technol Cancer Res Treatment 3 (2004) 429-436
    • (2004) Technol Cancer Res Treatment , vol.3 , pp. 429-436
    • Samei, E.1    Wright, S.L.2
  • 13
    • 17844408736 scopus 로고    scopus 로고
    • Assessment of display performance for medical imaging systems: executive summary of AAPM TG18 report
    • Samei E., Badano A., Chakraborty D., et al. Assessment of display performance for medical imaging systems: executive summary of AAPM TG18 report. Med Phys 32 (2005) 1205-1225
    • (2005) Med Phys , vol.32 , pp. 1205-1225
    • Samei, E.1    Badano, A.2    Chakraborty, D.3
  • 14
    • 7444233155 scopus 로고    scopus 로고
    • Physical characteristics of a full-field digital mammography system
    • Suryanarayanan S., Karellas A., and Vedantham S. Physical characteristics of a full-field digital mammography system. Nucl Instrum Methods 533 (2004) 560-570
    • (2004) Nucl Instrum Methods , vol.533 , pp. 560-570
    • Suryanarayanan, S.1    Karellas, A.2    Vedantham, S.3
  • 15
    • 0034068552 scopus 로고    scopus 로고
    • Full breast digital mammography with an amorphous silicon-based flat panel detector: physical characteristics of a clinical prototype
    • Vedantham S., Karellas A., Suryanarayanan S., et al. Full breast digital mammography with an amorphous silicon-based flat panel detector: physical characteristics of a clinical prototype. Med Phys 27 (2000) 558-567
    • (2000) Med Phys , vol.27 , pp. 558-567
    • Vedantham, S.1    Karellas, A.2    Suryanarayanan, S.3
  • 17
    • 12144258576 scopus 로고    scopus 로고
    • Characterization of breast masses for simulation purposes
    • Saunders R.S., and Samei E. Characterization of breast masses for simulation purposes. Proc SPIE 5372 (2004) 242-250
    • (2004) Proc SPIE , vol.5372 , pp. 242-250
    • Saunders, R.S.1    Samei, E.2
  • 19
    • 0037393386 scopus 로고    scopus 로고
    • An experimental comparison of detector performance for direct and indirect digital radiography systems
    • Samei E., and Flynn M.J. An experimental comparison of detector performance for direct and indirect digital radiography systems. Med Phys 30 (2003) 608-622
    • (2003) Med Phys , vol.30 , pp. 608-622
    • Samei, E.1    Flynn, M.J.2
  • 20
    • 0033735247 scopus 로고    scopus 로고
    • Scatter/primary in mammography: comprehensive results
    • Boone J.M., Lindfors K.K., Cooper III V.N., et al. Scatter/primary in mammography: comprehensive results. Med Phys 27 (2000) 2408-2416
    • (2000) Med Phys , vol.27 , pp. 2408-2416
    • Boone, J.M.1    Lindfors, K.K.2    Cooper III, V.N.3
  • 21
    • 0033983980 scopus 로고    scopus 로고
    • Digital radiography enhancement by nonlinear multiscale processing
    • Stahl M., Aach T., and Dippel S. Digital radiography enhancement by nonlinear multiscale processing. Med Phys 27 (2000) 56-65
    • (2000) Med Phys , vol.27 , pp. 56-65
    • Stahl, M.1    Aach, T.2    Dippel, S.3
  • 22
    • 0029715135 scopus 로고    scopus 로고
    • Optimizing the processing and presentation of PPCR imaging
    • Davies A.G., Cowen A.R., Parkin G.J.S., et al. Optimizing the processing and presentation of PPCR imaging. Proc SPIE 2712 (1996) 189-195
    • (1996) Proc SPIE , vol.2712 , pp. 189-195
    • Davies, A.G.1    Cowen, A.R.2    Parkin, G.J.S.3
  • 23
    • 23644440256 scopus 로고    scopus 로고
    • On-axis and off-axis viewing of images on CRT displays and LCDs: observer performance and vision model predictions
    • Krupinski E.A., Johnson J., Roehrig H., et al. On-axis and off-axis viewing of images on CRT displays and LCDs: observer performance and vision model predictions. Acad Radiol 12 (2005) 957-964
    • (2005) Acad Radiol , vol.12 , pp. 957-964
    • Krupinski, E.A.1    Johnson, J.2    Roehrig, H.3
  • 26
    • 1542788005 scopus 로고    scopus 로고
    • Liquid-crystal display monitors and cathode-ray tube monitors: a comparison of observer performance in the detection of small solitary pulmonary nodules
    • Hwang S.A., Seo J.B., Choi B.K., et al. Liquid-crystal display monitors and cathode-ray tube monitors: a comparison of observer performance in the detection of small solitary pulmonary nodules. Korean J Radiol 4 (2003) 153-156
    • (2003) Korean J Radiol , vol.4 , pp. 153-156
    • Hwang, S.A.1    Seo, J.B.2    Choi, B.K.3
  • 27
    • 22144449277 scopus 로고    scopus 로고
    • Comparison of liquid crystal versus cathode ray tube display for the detection of simulated chest lesions
    • Oschatz E., Prokop M., Scharitzer M., et al. Comparison of liquid crystal versus cathode ray tube display for the detection of simulated chest lesions. Eur Radiol 15 (2005) 1472-1476
    • (2005) Eur Radiol , vol.15 , pp. 1472-1476
    • Oschatz, E.1    Prokop, M.2    Scharitzer, M.3
  • 28
    • 12344299356 scopus 로고    scopus 로고
    • Detectability of catheters on bedside chest radiographs: comparison between liquid crystal display and high-resolution cathode-ray tube monitors
    • Scharitzer M., Prokop M., Weber M., et al. Detectability of catheters on bedside chest radiographs: comparison between liquid crystal display and high-resolution cathode-ray tube monitors. Radiology 234 (2005) 611-616
    • (2005) Radiology , vol.234 , pp. 611-616
    • Scharitzer, M.1    Prokop, M.2    Weber, M.3
  • 29
    • 13844275610 scopus 로고    scopus 로고
    • Use of a human visual system model to predict observer performance with CRT vs LCD display of images
    • Krupinski E.A., Johnson J., Roehrig H., et al. Use of a human visual system model to predict observer performance with CRT vs LCD display of images. J Dig Imaging 17 (2004) 258-263
    • (2004) J Dig Imaging , vol.17 , pp. 258-263
    • Krupinski, E.A.1    Johnson, J.2    Roehrig, H.3
  • 31
    • 13844299392 scopus 로고    scopus 로고
    • Breast cancer yield for screening mammographic examinations with recommendation for short-interval follow-up
    • Kerlikowske K., Smith-Bindman R., Abraham L.A., et al. Breast cancer yield for screening mammographic examinations with recommendation for short-interval follow-up. Radiology 234 (2005) 684-692
    • (2005) Radiology , vol.234 , pp. 684-692
    • Kerlikowske, K.1    Smith-Bindman, R.2    Abraham, L.A.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.