메뉴 건너뛰기




Volumn 31, Issue 4, 2004, Pages 715-723

Noise in flat-panel displays with subpixel structure

Author keywords

Liquid crystal display; Medical display; Noise; Noise power spectrum

Indexed keywords

CCD CAMERAS; FLAT PANEL DISPLAYS; LIGHT SOURCES; LIQUID CRYSTALS; LUMINANCE; PIXELS; POWER SPECTRUM;

EID: 1942452289     PISSN: 00942405     EISSN: None     Source Type: Journal    
DOI: 10.1118/1.1656529     Document Type: Article
Times cited : (31)

References (18)
  • 1
    • 0033228448 scopus 로고    scopus 로고
    • High fidelity electronic display of digital radiographs
    • M. J. Flynn, J. Kanicki, A. Badano, and W. R. Eyler, "High fidelity electronic display of digital radiographs," Radiographics 19, 1653-1669 (1999).
    • (1999) Radiographics , vol.19 , pp. 1653-1669
    • Flynn, M.J.1    Kanicki, J.2    Badano, A.3    Eyler, W.R.4
  • 2
    • 0029464488 scopus 로고
    • System to maintain perceptually linear networked display devices
    • D. A. Reimann, M. J. Flynn, and J. J. Ciarelli, "System to maintain perceptually linear networked display devices," Proc. SPIE 2431, 316-326 (1995).
    • (1995) Proc. SPIE , vol.2431 , pp. 316-326
    • Reimann, D.A.1    Flynn, M.J.2    Ciarelli, J.J.3
  • 3
    • 0142087066 scopus 로고    scopus 로고
    • Digital Imaging and Communications in Medicine (DICOM), Part 3.14, Grayscale Standard Display Function
    • National Electrical Manufacturers Association, "Digital Imaging and Communications in Medicine (DICOM), Part 3.14, Grayscale Standard Display Function," Technical report, ACR/NEMA, 1998.
    • (1998) Technical Report, ACR/NEMA
  • 4
    • 0036057738 scopus 로고    scopus 로고
    • Luminance effects on display resolution and noise
    • A. Badano, S. J. Hipper, and R. J. Jennings, "Luminance effects on display resolution and noise," Proc. SPIE 4681, 305-313 (2002).
    • (2002) Proc. SPIE , vol.4681 , pp. 305-313
    • Badano, A.1    Hipper, S.J.2    Jennings, R.J.3
  • 5
    • 0034859322 scopus 로고    scopus 로고
    • A method for in-field evaluation of the modulation transfer function of electronic display devices
    • E. Samei and M. J. Flynn, "A method for in-field evaluation of the modulation transfer function of electronic display devices," Proc. SPIE 4319, 599-607 (2001).
    • (2001) Proc. SPIE , vol.4319 , pp. 599-607
    • Samei, E.1    Flynn, M.J.2
  • 6
    • 0008929733 scopus 로고
    • Very-high-resolution monochrome CRT displays
    • H. Blume, H. Roehrig, and T. L. Ji, "Very-high-resolution monochrome CRT displays," Proc. S.I.D. 22, 355-358 (1991).
    • (1991) Proc. S.I.D. , vol.22 , pp. 355-358
    • Blume, H.1    Roehrig, H.2    Ji, T.L.3
  • 7
    • 0008886570 scopus 로고
    • Very-high-resolution CRT display systems
    • H. Blume, "Very-high-resolution CRT display systems," Proc. S.I.D. 23, 699-702 (1992).
    • (1992) Proc. S.I.D. , vol.23 , pp. 699-702
    • Blume, H.1
  • 8
    • 0001491386 scopus 로고
    • High-resolution high-brightness CRT display systems: Update on the state of the art
    • H. Blume et al., "High-resolution high-brightness CRT display systems: Update on the state of the art," J. Soc. Inf. Disp. 25, 219-222 (1992).
    • (1992) J. Soc. Inf. Disp. , vol.25 , pp. 219-222
    • Blume, H.1
  • 9
    • 0034877568 scopus 로고    scopus 로고
    • Visual CRT sharpness estimation using a fiducial marker set
    • K. Kohm, "Visual CRT sharpness estimation using a fiducial marker set," Proc. SPIE 4319, 286-297 (2001).
    • (2001) Proc. SPIE , vol.4319 , pp. 286-297
    • Kohm, K.1
  • 10
    • 0031339412 scopus 로고    scopus 로고
    • Impact of phosphor luminance noise on the specification of high-resolution CRT displays for medical imaging
    • E. Muka, T. Mertelmeier, and R. M. Slone, "Impact of phosphor luminance noise on the specification of high-resolution CRT displays for medical imaging," Proc. SPIE 3031, 210-221 (1997).
    • (1997) Proc. SPIE , vol.3031 , pp. 210-221
    • Muka, E.1    Mertelmeier, T.2    Slone, R.M.3
  • 11
    • 0027746633 scopus 로고
    • Noise of CRT display systems
    • H. Roehrig et al., "Noise of CRT display systems," Proc. SPIE 1897, 232-245 (1993).
    • (1993) Proc. SPIE , vol.1897 , pp. 232-245
    • Roehrig, H.1
  • 13
    • 33646647522 scopus 로고
    • Four-domain TN-LCD fabricated by reverse rubbing or double evaporation
    • J. Chen et al., "Four-domain TN-LCD fabricated by reverse rubbing or double evaporation," J. Soc. Inf. Disp. 26, 868-868 (1995).
    • (1995) J. Soc. Inf. Disp. , vol.26 , pp. 868-868
    • Chen, J.1
  • 14
    • 4243070996 scopus 로고    scopus 로고
    • Optical patterning of multidomain LCD with wide viewing angle
    • M. Schadt, H. Sieberle, and A. Schuster, "Optical patterning of multidomain LCD with wide viewing angle," Nature (London) 381, 212-215 (1996).
    • (1996) Nature (London) , vol.381 , pp. 212-215
    • Schadt, M.1    Sieberle, H.2    Schuster, A.3
  • 15
    • 0003908115 scopus 로고
    • ICRU Report 54: Medical Imaging - The Assesment of Image Quality
    • International Comission of Radiation Units and Measurements, "ICRU Report 54: Medical Imaging - The Assesment of Image Quality," ICRU, 1995.
    • (1995) ICRU
  • 16
    • 0034864236 scopus 로고    scopus 로고
    • A standard illumination source for the evaluation of display measurement methods and instruments
    • J. M. Libert, P. A. Boynton, and E. F. Kelley, "A standard illumination source for the evaluation of display measurement methods and instruments," Proc. SPIE 4295, 279-286 (2000).
    • (2000) Proc. SPIE , vol.4295 , pp. 279-286
    • Libert, J.M.1    Boynton, P.A.2    Kelley, E.F.3
  • 17
    • 0000828954 scopus 로고    scopus 로고
    • A method for measuring veiling glare in high performance display devices
    • A. Badano and M. J. Flynn, "A method for measuring veiling glare in high performance display devices," Appl. Opt. 39, 2059-2066 (2000).
    • (2000) Appl. Opt. , vol.39 , pp. 2059-2066
    • Badano, A.1    Flynn, M.J.2
  • 18
    • 0026837927 scopus 로고
    • A simple method for determining the modulation transfer function in digital radiography
    • H. Fujita, D. Tsai, T. Itoh, K. Doi, J. Morishita, and K. Uedo, "A simple method for determining the modulation transfer function in digital radiography," IEEE Trans. Med. Imaging 11, 34-39 (1992).
    • (1992) IEEE Trans. Med. Imaging , vol.11 , pp. 34-39
    • Fujita, H.1    Tsai, D.2    Itoh, T.3    Doi, K.4    Morishita, J.5    Uedo, K.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.