메뉴 건너뛰기




Volumn 2006, Issue , 2006, Pages 498-501

Bulk titanium microneedles with embedded microfluidic networks for transdermal drug delivery

Author keywords

[No Author keywords available]

Indexed keywords

BIOCOMPATIBILITY; BIOMEDICAL ENGINEERING; DRUG PRODUCTS; EMBEDDED SYSTEMS; FRACTURE TOUGHNESS; MICROELECTROMECHANICAL DEVICES;

EID: 33750108034     PISSN: 10846999     EISSN: None     Source Type: Conference Proceeding    
DOI: None     Document Type: Conference Paper
Times cited : (11)

References (16)
  • 1
  • 2
    • 18144397536 scopus 로고    scopus 로고
    • Microsystems for drug and gene delivery
    • M. L. Reed and W.-K. Lei, "Microsystems for Drug and Gene Delivery," P. IEEE, vol. 92, no. 1, pp. 56-75, 2004.
    • (2004) P. IEEE , vol.92 , Issue.1 , pp. 56-75
    • Reed, M.L.1    Lei, W.-K.2
  • 3
    • 0037871729 scopus 로고    scopus 로고
    • Side-opened out-of-plane microneedles for microfluidic transdermal liquid transfer
    • P. Griss and G. Stemme, "Side-Opened Out-of-Plane Microneedles for Microfluidic Transdermal Liquid Transfer," J. Microelectromech. Syst., vol. 12, no. 3, pp. 296-301, 2003.
    • (2003) J. Microelectromech. Syst. , vol.12 , Issue.3 , pp. 296-301
    • Griss, P.1    Stemme, G.2
  • 5
    • 4344666269 scopus 로고    scopus 로고
    • Microneedle array for transdermal biological fluid extraction and in situ analysis
    • E. V. Mukerjee, S. D. Collins, R. R. Isseroff, and R. L. Smith, "Microneedle Array for Transdermal Biological Fluid Extraction and In Situ Analysis," Sensor Act. A, vol. 114, pp. 267-275, 2004.
    • (2004) Sensor Act. A , vol.114 , pp. 267-275
    • Mukerjee, E.V.1    Collins, S.D.2    Isseroff, R.R.3    Smith, R.L.4
  • 6
    • 22444434334 scopus 로고    scopus 로고
    • Arrays of hollow out-of-plane microneedles for drug delivery
    • B. Stoeber and D. Liepmann, "Arrays of Hollow Out-of-Plane Microneedles for Drug Delivery," J. Microelectromech. Syst., vol. 14, no. 3, pp. 472-479, 2005.
    • (2005) J. Microelectromech. Syst. , vol.14 , Issue.3 , pp. 472-479
    • Stoeber, B.1    Liepmann, D.2
  • 7
    • 18144410179 scopus 로고    scopus 로고
    • Biodegradable polymer microneedles: Fabrication, mechanics, and transdermal drug delivery
    • J.-H. Park, M. G. Allen, and M. R. Praunitz, "Biodegradable Polymer Microneedles: Fabrication, Mechanics, and Transdermal Drug Delivery," J. Control. Release, vol. 104, pp. 51-66, 2005.
    • (2005) J. Control. Release , vol.104 , pp. 51-66
    • Park, J.-H.1    Allen, M.G.2    Praunitz, M.R.3
  • 8
    • 18744377499 scopus 로고    scopus 로고
    • Hollow metallic microneedles for insulin delivery to diabetic rats
    • S. P. Davis, W. Martanto, M. G. Allen, and M. R. Praunitz, "Hollow Metallic Microneedles for Insulin Delivery to Diabetic Rats," IEEE Trans. Biomed. Eng., vol. 52, no. 5, pp. 909-915, 2005.
    • (2005) IEEE Trans. Biomed. Eng. , vol.52 , Issue.5 , pp. 909-915
    • Davis, S.P.1    Martanto, W.2    Allen, M.G.3    Praunitz, M.R.4
  • 9
    • 0033100851 scopus 로고    scopus 로고
    • Silicon-processed microneedles
    • L. W. Lin and A. P. Pisano, "Silicon-Processed Microneedles," J. Microelectromech. Syst., vol. 8, no. 1, pp. 78-84, 1999.
    • (1999) J. Microelectromech. Syst. , vol.8 , Issue.1 , pp. 78-84
    • Lin, L.W.1    Pisano, A.P.2
  • 10
    • 0031214943 scopus 로고    scopus 로고
    • A multichannel neural probe for selective chemical delivery at the cellular level
    • J. K. Chen, K. D. Wise, J. F. Hetke, and S. C. Bledsoe, "A Multichannel Neural Probe for Selective Chemical Delivery at the Cellular Level," IEEE Trans. Biomed Engr., vol. 44, no. 8, pp. 760-769, 1997.
    • (1997) IEEE Trans. Biomed Engr. , vol.44 , Issue.8 , pp. 760-769
    • Chen, J.K.1    Wise, K.D.2    Hetke, J.F.3    Bledsoe, S.C.4
  • 11
    • 4344679112 scopus 로고    scopus 로고
    • In-plane single-crystal-silicon microneedles for minimally invasive microfluid systems
    • S.-J. Paik, S. Byun, J.-M. Lim, Y. Park, A. Lee, S. Chung, J. Chang, K. Chun, and D. Cho, "In-Plane Single-Crystal-Silicon Microneedles for Minimally Invasive Microfluid Systems," Sensor Act. A, vol. 114, pp. 276-284, 2004.
    • (2004) Sensor Act. A , vol.114 , pp. 276-284
    • Paik, S.-J.1    Byun, S.2    Lim, J.-M.3    Park, Y.4    Lee, A.5    Chung, S.6    Chang, J.7    Chun, K.8    Cho, D.9
  • 12
    • 0008670190 scopus 로고    scopus 로고
    • Microfabricated polysilicon microneedles for minimally invasive biomedical devices
    • J. D. Zahn, N. H. Talbot, D. Liepmann, and A. P. Pisano, "Microfabricated Polysilicon Microneedles for Minimally Invasive Biomedical Devices," Biomed. Microdev., vol. 2, pp. 295-303, 2000.
    • (2000) Biomed. Microdev. , vol.2 , pp. 295-303
    • Zahn, J.D.1    Talbot, N.H.2    Liepmann, D.3    Pisano, A.P.4
  • 16
    • 27644530968 scopus 로고    scopus 로고
    • Inductively coupled plasma etching of bulk titanium for MEMS applications
    • E. R. Parker, B. J. Thibeault, M. F. Aimi, M. P. Rao, and N. C. MacDonald, "Inductively Coupled Plasma Etching of Bulk Titanium for MEMS Applications," J. Electrochem. Soc., vol. 152, no. 10, pp. 675-683, 2005.
    • (2005) J. Electrochem. Soc. , vol.152 , Issue.10 , pp. 675-683
    • Parker, E.R.1    Thibeault, B.J.2    Aimi, M.F.3    Rao, M.P.4    MacDonald, N.C.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.