-
1
-
-
33750071130
-
Biological evaluation of medical devices - Part 6: Local effects after implantation
-
AFNOR
-
AFNOR (2005) [Biological evaluation of medical devices - part 6: local effects after implantation]. J Off Repub Fr 70
-
(2005)
J Off Repub Fr
, vol.70
-
-
-
2
-
-
0033493426
-
Posterior lumbar interbody fusion with cages: An independent review of 71 cases
-
Agazzi S, Reverdin A, May D (1999) Posterior lumbar interbody fusion with cages: an independent review of 71 cases. J Neurosurg 91:186-192
-
(1999)
J Neurosurg
, vol.91
, pp. 186-192
-
-
Agazzi, S.1
Reverdin, A.2
May, D.3
-
3
-
-
0036829046
-
Applications of a resorbable interbody spacer in posterior lumbar interbody fusion
-
Alexander JT, Branch CL Jr, Subach BR et al (2002a) Applications of a resorbable interbody spacer in posterior lumbar interbody fusion. J Neurosurg 97:468-472
-
(2002)
J Neurosurg
, vol.97
, pp. 468-472
-
-
Alexander, J.T.1
Branch Jr., C.L.2
Subach, B.R.3
-
4
-
-
0036804064
-
Applications of a resorbable interbody spacer via a posterior lumbar interbody fusion technique
-
Alexander JT, Branch CL Jr, Subach BR et al (2002b) Applications of a resorbable interbody spacer via a posterior lumbar interbody fusion technique. Orthopedics 25:s1185-s1189
-
(2002)
Orthopedics
, vol.25
-
-
Alexander, J.T.1
Branch Jr., C.L.2
Subach, B.R.3
-
5
-
-
0034672866
-
Pre-clinical in vivo evaluation of orthopaedic bioabsorbable devices
-
An YH, Woolf SK, Friedman RJ (2000) Pre-clinical in vivo evaluation of orthopaedic bioabsorbable devices. Biomaterials 21:2635-2652
-
(2000)
Biomaterials
, vol.21
, pp. 2635-2652
-
-
An, Y.H.1
Woolf, S.K.2
Friedman, R.J.3
-
6
-
-
0028878553
-
Late degradation tissue response to poly(L-lactide) bone plates and screws
-
Bergsma JE, de Bruijn WC, Rozema FR et al (1995a) Late degradation tissue response to poly(L-lactide) bone plates and screws. Biomaterials 16:25-31
-
(1995)
Biomaterials
, vol.16
, pp. 25-31
-
-
Bergsma, J.E.1
De Bruijn, W.C.2
Rozema, F.R.3
-
7
-
-
0029256566
-
In vivo degradation and biocompatibility study of in vitro pre-degraded as-polymerized polyactide particles
-
Bergsma JE, Rozema FR, Bos RR et al (1995b) In vivo degradation and biocompatibility study of in vitro pre-degraded as-polymerized polyactide particles. Biomaterials 16:267-274
-
(1995)
Biomaterials
, vol.16
, pp. 267-274
-
-
Bergsma, J.E.1
Rozema, F.R.2
Bos, R.R.3
-
8
-
-
0343353897
-
Clinical biocompatibility of biodegradable orthopaedic implants for internal fixation: A review
-
Bostman O, Pihlajamaki H (2000) Clinical biocompatibility of biodegradable orthopaedic implants for internal fixation: a review. Biomaterials 21:2615-2621
-
(2000)
Biomaterials
, vol.21
, pp. 2615-2621
-
-
Bostman, O.1
Pihlajamaki, H.2
-
9
-
-
0027423357
-
A carbon fiber implant to aid interbody lumbar fusion. Two-year clinical results in the first 26 patients
-
Brantigan JW, Steffee AD (1993) A carbon fiber implant to aid interbody lumbar fusion. Two-year clinical results in the first 26 patients. Spine 18:2106-2107
-
(1993)
Spine
, vol.18
, pp. 2106-2107
-
-
Brantigan, J.W.1
Steffee, A.D.2
-
10
-
-
0026473093
-
Biodegradable rods versus Kirschner wire fixation of wrist fractures. A randomised trial
-
Casteleyn PP, Handelberg F, Haentjens P (1992) Biodegradable rods versus Kirschner wire fixation of wrist fractures. A randomised trial. J Bone Joint Surg Br 74:858-861
-
(1992)
J Bone Joint Surg Br
, vol.74
, pp. 858-861
-
-
Casteleyn, P.P.1
Handelberg, F.2
Haentjens, P.3
-
11
-
-
0037339640
-
Preparation and characterization of biodegradable PLA polymeric blends
-
Chen C, Chueh J, Tseng H et al (2003) Preparation and characterization of biodegradable PLA polymeric blends. Biomaterials 24:1167-1173
-
(2003)
Biomaterials
, vol.24
, pp. 1167-1173
-
-
Chen, C.1
Chueh, J.2
Tseng, H.3
-
12
-
-
0035462850
-
Bioabsorbable implants in orthopaedics: New developments and clinical applications
-
Ciccone WJ 2nd, Motz C, Bentley C et al (2001) Bioabsorbable implants in orthopaedics: new developments and clinical applications. J Am Acad Orthop Surg 9:280-288
-
(2001)
J Am Acad Orthop Surg
, vol.9
, pp. 280-288
-
-
Ciccone II, W.J.1
Motz, C.2
Bentley, C.3
-
13
-
-
0028852608
-
Large amounts of polylactic acid in contact with divided nerve sheaths have no adverse effects on regeneration
-
de Medinaceli L, al Khoury R, Merle M (1995) Large amounts of polylactic acid in contact with divided nerve sheaths have no adverse effects on regeneration. J Reconstr Microsurg 11:43-49
-
(1995)
J Reconstr Microsurg
, vol.11
, pp. 43-49
-
-
De Medinaceli, L.1
Al Khoury, R.2
Merle, M.3
-
14
-
-
0019947037
-
A method for the study of undecalcified bones and teeth with attached soft tissues. The Sage-Schliff (sawing and grinding) technique
-
Donath K, Breuner G (1982) A method for the study of undecalcified bones and teeth with attached soft tissues. The Sage-Schliff (sawing and grinding) technique. J Oral Pathol 11:318-326
-
(1982)
J Oral Pathol
, vol.11
, pp. 318-326
-
-
Donath, K.1
Breuner, G.2
-
15
-
-
33750070677
-
Spinal fusion with bioresorbable cages - Severe degradation effects
-
Eindorf T, Pflugmacher R, Koch C et al (2005) Spinal fusion with bioresorbable cages - severe degradation effects. Eur Spine J 14:S20
-
(2005)
Eur Spine J
, vol.14
-
-
Eindorf, T.1
Pflugmacher, R.2
Koch, C.3
-
16
-
-
0034446599
-
Bioresorbable polymers in trauma and bone surgery
-
Gogolewski S (2000) Bioresorbable polymers in trauma and bone surgery. Injury 31(Suppl 4):28-32
-
(2000)
Injury
, vol.31
, Issue.SUPPL. 4
, pp. 28-32
-
-
Gogolewski, S.1
-
17
-
-
0026575586
-
Osteosynthesis of distal radius fractures with biodegradable fracture rods. Results of two years follow-up
-
Hoffmann R, Krettek C, Hetkamper A et al (1992) [Osteosynthesis of distal radius fractures with biodegradable fracture rods. Results of two years follow-up]. Unfallchirurg 95:99-105
-
(1992)
Unfallchirurg
, vol.95
, pp. 99-105
-
-
Hoffmann, R.1
Krettek, C.2
Hetkamper, A.3
-
18
-
-
0022738051
-
Biodegradable bone repair materials. Synthetic polymers and ceramics
-
Hollinger JO, Battistone GC (1986) Biodegradable bone repair materials. Synthetic polymers and ceramics. Clin Orthop 290-305
-
(1986)
Clin Orthop
, pp. 290-305
-
-
Hollinger, J.O.1
Battistone, G.C.2
-
19
-
-
0034432931
-
In vitro biomechanical investigation of the stability and stress-shielding effect of lumbar interbody fusion devices
-
Kanayama M, Cunningham BW, Haggerty CJ et al (2000) In vitro biomechanical investigation of the stability and stress-shielding effect of lumbar interbody fusion devices. J Neurosurg 93:259-265
-
(2000)
J Neurosurg
, vol.93
, pp. 259-265
-
-
Kanayama, M.1
Cunningham, B.W.2
Haggerty, C.J.3
-
20
-
-
4444251679
-
Bioabsorbable interbody cages in a sheep cervical spine fusion model
-
Kandziora F, Pflugmacher R, Scholz M et al (2004) Bioabsorbable interbody cages in a sheep cervical spine fusion model. Spine 29:1845-1855
-
(2004)
Spine
, vol.29
, pp. 1845-1855
-
-
Kandziora, F.1
Pflugmacher, R.2
Scholz, M.3
-
21
-
-
0034667346
-
Four-year follow-up results of lumbar spine arthrodesis using the Bagby and Kuslich lumbar fusion cage
-
Kuslich SD, Danielson G, Dowdle JD et al (2000) Four-year follow-up results of lumbar spine arthrodesis using the Bagby and Kuslich lumbar fusion cage. Spine 25:2656-2662
-
(2000)
Spine
, vol.25
, pp. 2656-2662
-
-
Kuslich, S.D.1
Danielson, G.2
Dowdle, J.D.3
-
22
-
-
0026658355
-
Guided bone regeneration of cranial defects, using biodegradable barriers: An experimental pilot study in the rabbit
-
Lundgren D, Nyman S, Mathisen T et al (1992) Guided bone regeneration of cranial defects, using biodegradable barriers: an experimental pilot study in the rabbit. J Craniomaxillofac Surg 20:257-260
-
(1992)
J Craniomaxillofac Surg
, vol.20
, pp. 257-260
-
-
Lundgren, D.1
Nyman, S.2
Mathisen, T.3
-
23
-
-
0031081408
-
Long-term in vivo degradation and bone reaction to various polylactides. 1. One-year results
-
Mainil-Varlet P, Rahn B, Gogolewski S (1997) Long-term in vivo degradation and bone reaction to various polylactides. 1. One-year results. Biomaterials 18:257-266
-
(1997)
Biomaterials
, vol.18
, pp. 257-266
-
-
Mainil-Varlet, P.1
Rahn, B.2
Gogolewski, S.3
-
24
-
-
0033022140
-
Interbody fusion cages in reconstructive operations on the spine
-
McAfee PC (1999a) Interbody fusion cages in reconstructive operations on the spine. J Bone Joint Surg Am 81:859-880
-
(1999)
J Bone Joint Surg Am
, vol.81
, pp. 859-880
-
-
McAfee, P.C.1
-
25
-
-
0033570134
-
Revision strategies for salvaging or improving failed cylindrical cages
-
McAfee PC, Cunningham BW, Lee GA et al (1999b) Revision strategies for salvaging or improving failed cylindrical cages. Spine 24:2147-2153
-
(1999)
Spine
, vol.24
, pp. 2147-2153
-
-
McAfee, P.C.1
Cunningham, B.W.2
Lee, G.A.3
-
26
-
-
0029444923
-
In vitro study of the properties of bioresorbable lactic acid polymer materials
-
Merloz P, Minfelde R, Schelp C et al (1995) [In vitro study of the properties of bioresorbable lactic acid polymer materials]. Rev Chir Orthop Reparatrice Appar Mot 81:433-444
-
(1995)
Rev Chir Orthop Reparatrice Appar Mot
, vol.81
, pp. 433-444
-
-
Merloz, P.1
Minfelde, R.2
Schelp, C.3
-
27
-
-
0031936988
-
The Ray threaded fusion cage for posterior lumbar interbody fusion
-
Onesti ST, Ashkenazi E (1998) The Ray threaded fusion cage for posterior lumbar interbody fusion. Neurosurgery 42:200-204
-
(1998)
Neurosurgery
, vol.42
, pp. 200-204
-
-
Onesti, S.T.1
Ashkenazi, E.2
-
28
-
-
0031260504
-
In vivo monitoring of the degradation process of bioresorbable polymeric implants using magnetic resonance imaging
-
Pihlajamaki H, Kinnunen J, Bostman O (1997) In vivo monitoring of the degradation process of bioresorbable polymeric implants using magnetic resonance imaging. Biomaterials 18:1311-1315
-
(1997)
Biomaterials
, vol.18
, pp. 1311-1315
-
-
Pihlajamaki, H.1
Kinnunen, J.2
Bostman, O.3
-
29
-
-
0027625652
-
Poly(L-lactide): A long-term degradation study in vivo. I. Biological results
-
Pistner H, Gutwald R, Ordung R et al (1993) Poly(L-lactide): a long-term degradation study in vivo. I. Biological results. Biomaterials 14:671-677
-
(1993)
Biomaterials
, vol.14
, pp. 671-677
-
-
Pistner, H.1
Gutwald, R.2
Ordung, R.3
-
30
-
-
0030910461
-
Threaded titanium cages for lumbar interbody fusions
-
Ray CD (1997) Threaded titanium cages for lumbar interbody fusions. Spine 22:667-679
-
(1997)
Spine
, vol.22
, pp. 667-679
-
-
Ray, C.D.1
-
31
-
-
0033558305
-
Laparoscopic fusion of the lumbar spine: Minimally invasive spine surgery. A prospective multicenter study evaluating open and laparoscopic lumbar fusion
-
Regan JJ, Yuan H, McAfee PC (1999) Laparoscopic fusion of the lumbar spine: minimally invasive spine surgery. A prospective multicenter study evaluating open and laparoscopic lumbar fusion. Spine 24:402-411
-
(1999)
Spine
, vol.24
, pp. 402-411
-
-
Regan, J.J.1
Yuan, H.2
McAfee, P.C.3
-
32
-
-
0024574275
-
A critique of posterior lumbar interbody fusion: 12 Years' experience with 250 patients
-
Rish BL (1989) A critique of posterior lumbar interbody fusion: 12 years' experience with 250 patients. Surg Neurol 31:281-289
-
(1989)
Surg Neurol
, vol.31
, pp. 281-289
-
-
Rish, B.L.1
-
33
-
-
0343353899
-
Bioabsorbable fixation in orthopaedic surgery and traumatology
-
Rokkanen PU, Bostman O, Hirvensalo E et al (2000) Bioabsorbable fixation in orthopaedic surgery and traumatology. Biomaterials 21:2607-2613
-
(2000)
Biomaterials
, vol.21
, pp. 2607-2613
-
-
Rokkanen, P.U.1
Bostman, O.2
Hirvensalo, E.3
-
34
-
-
0037082723
-
Influence of polymerization conditions on the hydrolytic degradation of poly(DL-lactide) polymerized in the presence of stannous octoate or zinc-metal
-
Schwach G, Coudane J, Engel R et al (2002) Influence of polymerization conditions on the hydrolytic degradation of poly(DL-lactide) polymerized in the presence of stannous octoate or zinc-metal. Biomaterials 23:993-1002
-
(2002)
Biomaterials
, vol.23
, pp. 993-1002
-
-
Schwach, G.1
Coudane, J.2
Engel, R.3
-
35
-
-
0032967708
-
In vitro and in vivo degradation of lactic acid-based interference screws used in cruciate ligament reconstruction
-
Schwach G, Vert M (1999) In vitro and in vivo degradation of lactic acid-based interference screws used in cruciate ligament reconstruction. Int J Biol Macromol 25:283-291
-
(1999)
Int J Biol Macromol
, vol.25
, pp. 283-291
-
-
Schwach, G.1
Vert, M.2
-
36
-
-
0041736430
-
Comparison of plain radiographs with CT scan to evaluate interbody fusion following the use of titanium interbody cages and transpedicular instrumentation
-
Shah RR, Mohammed S, Saifuddin A et al (2003) Comparison of plain radiographs with CT scan to evaluate interbody fusion following the use of titanium interbody cages and transpedicular instrumentation. Eur Spine J 12:378-385
-
(2003)
Eur Spine J
, vol.12
, pp. 378-385
-
-
Shah, R.R.1
Mohammed, S.2
Saifuddin, A.3
-
37
-
-
0042975377
-
Changes in bone architecture during spinal fusion: Three years follow-up and the role of cage stiffness
-
Smit TH, Muller R, Van Dijk M et al (2003) Changes in bone architecture during spinal fusion: three years follow-up and the role of cage stiffness. Spine 28:1802-1808
-
(2003)
Spine
, vol.28
, pp. 1802-1808
-
-
Smit, T.H.1
Muller, R.2
Van Dijk, M.3
-
38
-
-
0035893915
-
Bone graft incorporation in radiographically successful human intervertebral body fusion cages
-
Togawa D, Bauer TW, Brantigan JW et al (2001) Bone graft incorporation in radiographically successful human intervertebral body fusion cages. Spine 26:2744-2750
-
(2001)
Spine
, vol.26
, pp. 2744-2750
-
-
Togawa, D.1
Bauer, T.W.2
Brantigan, J.W.3
-
39
-
-
0036829097
-
Evaluation of 70/30 poly (L-lactide-co-DL-lactide) for use as a resorbable interbody fusion cage
-
Toth JM, Estes BT, Wang M et al (2002a) Evaluation of 70/30 poly (L-lactide-co-DL-lactide) for use as a resorbable interbody fusion cage. J Neurosurg 97:423-432
-
(2002)
J Neurosurg
, vol.97
, pp. 423-432
-
-
Toth, J.M.1
Estes, B.T.2
Wang, M.3
-
40
-
-
0036804991
-
Evaluation of 70/30 D,L-PLa for use as a resorbable interbody fusion cage
-
Toth JM, Wang M, Scifert JL et al (2002b) Evaluation of 70/30 D,L-PLa for use as a resorbable interbody fusion cage. Orthopedics 25:s1131-s1140
-
(2002)
Orthopedics
, vol.25
-
-
Toth, J.M.1
Wang, M.2
Scifert, J.L.3
-
41
-
-
0032528898
-
Failure of a carbon fiber implant. A case report
-
Tullberg T (1998) Failure of a carbon fiber implant. A case report. Spine 23:1804-1806
-
(1998)
Spine
, vol.23
, pp. 1804-1806
-
-
Tullberg, T.1
-
42
-
-
0029856691
-
In vivo degradation and biocompatability study of in vitro pre-degraded as-polymerized polylactide particles
-
Tunc DC (1996) In vivo degradation and biocompatability study of in vitro pre-degraded as-polymerized polylactide particles. Biomaterials 17:2109-2112
-
(1996)
Biomaterials
, vol.17
, pp. 2109-2112
-
-
Tunc, D.C.1
-
43
-
-
0036894574
-
Bioabsorbable poly-L-lactic acid cages for lumbar interbody fusion: Three-year follow-up radiographic, histologic, and histomorphometric analysis in goats
-
van Dijk M, Smit TH, Burger EH et al (2002a) Bioabsorbable poly-L-lactic acid cages for lumbar interbody fusion: three-year follow-up radiographic, histologic, and histomorphometric analysis in goats. Spine 27:2706-2714
-
(2002)
Spine
, vol.27
, pp. 2706-2714
-
-
Van Dijk, M.1
Smit, T.H.2
Burger, E.H.3
-
44
-
-
0036534292
-
The effect of cage stiffness on the rate of lumbar interbody fusion: An in vivo model using poly(l-lactic Acid) and titanium cages
-
van Dijk M, Smit TH, Sugihara S et al (2002b) The effect of cage stiffness on the rate of lumbar interbody fusion: an in vivo model using poly(l-lactic Acid) and titanium cages. Spine 27:682-688
-
(2002)
Spine
, vol.27
, pp. 682-688
-
-
Van Dijk, M.1
Smit, T.H.2
Sugihara, S.3
-
45
-
-
1842836455
-
In vitro and in vivo degradation of bioabsorbable PLLA spinal fusion cages
-
van Dijk M, Tunc DC, Smit TH et al (2002c) In vitro and in vivo degradation of bioabsorbable PLLA spinal fusion cages. J Biomed Mater Res 63:752-759
-
(2002)
J Biomed Mater Res
, vol.63
, pp. 752-759
-
-
Van Dijk, M.1
Tunc, D.C.2
Smit, T.H.3
-
46
-
-
15544389086
-
Four-year follow-up of poly-L-lactic acid cages for lumbar interbody fusion in goats
-
van Dijk M, van Diest PJ, Smit TH et al (2005) Four-year follow-up of poly-L-lactic acid cages for lumbar interbody fusion in goats. J Long Term Eff Med Implants 15:125-138
-
(2005)
J Long Term Eff Med Implants
, vol.15
, pp. 125-138
-
-
Van Dijk, M.1
Van Diest, P.J.2
Smit, T.H.3
-
47
-
-
0029394777
-
Bone changes after experimental osteotomies fixed with absorbable self-reinforced poly-L-lactide screws or metallic screws studied by plain radiographs, quantitative computed tomography and magnetic resonance imaging
-
Viljanen J, Kinnunen J, Bondestam S et al (1995) Bone changes after experimental osteotomies fixed with absorbable self-reinforced poly-L-lactide screws or metallic screws studied by plain radiographs, quantitative computed tomography and magnetic resonance imaging. Biomaterials 16:1353-1358
-
(1995)
Biomaterials
, vol.16
, pp. 1353-1358
-
-
Viljanen, J.1
Kinnunen, J.2
Bondestam, S.3
-
48
-
-
0033023293
-
Magnetic resonance imaging of bioabsorbale polylactic acid interference screws during the first 2 years after anterior cruciate ligament reconstruction
-
Warden WH, Friedman R, Teresi LM et al (1999) Magnetic resonance imaging of bioabsorbale polylactic acid interference screws during the first 2 years after anterior cruciate ligament reconstruction. Arthroscopy 15:474-480
-
(1999)
Arthroscopy
, vol.15
, pp. 474-480
-
-
Warden, W.H.1
Friedman, R.2
Teresi, L.M.3
-
49
-
-
0029891715
-
Foreign-body reaction and the course of osteolysis after polyglycolide implants for fracture fixation: Experimental study in sheep
-
Weiler A, Helling HJ, Kirch U et al (1996) Foreign-body reaction and the course of osteolysis after polyglycolide implants for fracture fixation: experimental study in sheep. J Bone Joint Surg Br 78:369-376
-
(1996)
J Bone Joint Surg Br
, vol.78
, pp. 369-376
-
-
Weiler, A.1
Helling, H.J.2
Kirch, U.3
-
50
-
-
0034114212
-
Biodegradable implants in sports medicine: The biological base
-
Weiler A, Hoffmann RF, Stahelin AC et al (2000) Biodegradable implants in sports medicine: the biological base. Arthroscopy 16:305-321
-
(2000)
Arthroscopy
, vol.16
, pp. 305-321
-
-
Weiler, A.1
Hoffmann, R.F.2
Stahelin, A.C.3
-
51
-
-
0032033434
-
Spine update lumbar interbody cages
-
Weiner BK, Fraser RD (1998) Spine update lumbar interbody cages. Spine 23:634-640
-
(1998)
Spine
, vol.23
, pp. 634-640
-
-
Weiner, B.K.1
Fraser, R.D.2
-
52
-
-
0031284671
-
Are sheep spines a valid biomechanical model for human spines?
-
Wilke HJ, Kettler A, Claes LE (1997) Are sheep spines a valid biomechanical model for human spines? Spine 22:2365-2374
-
(1997)
Spine
, vol.22
, pp. 2365-2374
-
-
Wilke, H.J.1
Kettler, A.2
Claes, L.E.3
-
53
-
-
0036830373
-
Resorbable cages for spinal fusion: An experimental goat model
-
Wuisman PI, van Dijk M, Smit TH (2002) Resorbable cages for spinal fusion: an experimental goat model. J Neurosurg 97:433-439
-
(2002)
J Neurosurg
, vol.97
, pp. 433-439
-
-
Wuisman, P.I.1
Van Dijk, M.2
Smit, T.H.3
|