메뉴 건너뛰기




Volumn 63, Issue 6, 2002, Pages 752-759

In vitro and in vivo degradation of bioabsorbable PLLA spinal fusion cages

Author keywords

High load bearing; In vitro and in vivo degradation; Lumbar interbody fusion; Poly L lactic acid; Spinal fusion cage

Indexed keywords

ABSORPTION; BONE; DEGRADATION; GRAFTS; IMPLANTS (SURGICAL); STRENGTH OF MATERIALS; VISCOSITY;

EID: 1842836455     PISSN: 00219304     EISSN: None     Source Type: Journal    
DOI: 10.1002/jbm.10466     Document Type: Article
Times cited : (74)

References (45)
  • 1
    • 0023802243 scopus 로고
    • Arthrodesis by the distraction-compression method using a stainless steel implant
    • Bagby GW. Arthrodesis by the distraction-compression method using a stainless steel implant. Orthopedics 1988;11:931-934.
    • (1988) Orthopedics , vol.11 , pp. 931-934
    • Bagby, G.W.1
  • 2
    • 0030910461 scopus 로고    scopus 로고
    • Threaded titanium cages for lumbar interbody fusions
    • Ray CD. Threaded titanium cages for lumbar interbody fusions. Spine 1997;22:667-679.
    • (1997) Spine , vol.22 , pp. 667-679
    • Ray, C.D.1
  • 3
    • 0033493426 scopus 로고    scopus 로고
    • Posterior lumbar interbody fusion with cages: An independent review of 71 cases
    • Agazzi S, Reverdin A, May D. Posterior lumbar interbody fusion with cages: An independent review of 71 cases. J Neurosurg 1999;91:186-192.
    • (1999) J Neurosurg , vol.91 , pp. 186-192
    • Agazzi, S.1    Reverdin, A.2    May, D.3
  • 4
    • 0027423357 scopus 로고
    • A carbon fiber implant to aid interbody lumbar fusion. Two-year clinical results in the first 26 patients
    • Brantigan JW, Steffee AD. A carbon fiber implant to aid interbody lumbar fusion. Two-year clinical results in the first 26 patients. Spine 1993;18:2106-2107.
    • (1993) Spine , vol.18 , pp. 2106-2107
    • Brantigan, J.W.1    Steffee, A.D.2
  • 5
    • 0032123113 scopus 로고    scopus 로고
    • Minimally invasive anterior retroperitoneal approach to the lumbar spine. Emphasis on the lateral BAK
    • McAfee PC, Regan JJ, Geis WP, Fedder IL. Minimally invasive anterior retroperitoneal approach to the lumbar spine. Emphasis on the lateral BAK. Spine 1998;23:1476-1484.
    • (1998) Spine , vol.23 , pp. 1476-1484
    • McAfee, P.C.1    Regan, J.J.2    Geis, W.P.3    Fedder, I.L.4
  • 6
    • 0032101704 scopus 로고    scopus 로고
    • The Bagby and Kuslich method of lumbar interbody fusion. History, techniques, and 2-year follow-up results of a United States prospective, multicenter trial
    • Kuslich SD, Ulstrom CL, Griffith SL, Ahern JW, Dowdle JD. The Bagby and Kuslich method of lumbar interbody fusion. History, techniques, and 2-year follow-up results of a United States prospective, multicenter trial. Spine 1998;23:1267-1278.
    • (1998) Spine , vol.23 , pp. 1267-1278
    • Kuslich, S.D.1    Ulstrom, C.L.2    Griffith, S.L.3    Ahern, J.W.4    Dowdle, J.D.5
  • 7
    • 0028217636 scopus 로고
    • Pseudarthrosis rate after allograft posterior lumbar interbody fusion with pedicle screw and plate fixation
    • Brantigan JW. Pseudarthrosis rate after allograft posterior lumbar interbody fusion with pedicle screw and plate fixation. Spine 1994;19:271-1279.
    • (1994) Spine , vol.19 , pp. 271-1279
    • Brantigan, J.W.1
  • 9
    • 0032033434 scopus 로고    scopus 로고
    • Spine update. Lumbar interbody cages
    • Weiner BK, Fraser RD. Spine update. Lumbar interbody cages. Spine 1998;23:634-640.
    • (1998) Spine , vol.23 , pp. 634-640
    • Weiner, B.K.1    Fraser, R.D.2
  • 10
    • 0033022140 scopus 로고    scopus 로고
    • Interbody fusion cages in reconstructive operations on the spine
    • McAfee PC. Interbody fusion cages in reconstructive operations on the spine. J Bone Joint Surg Am 1999;81:859-880.
    • (1999) J Bone Joint Surg Am , vol.81 , pp. 859-880
    • McAfee, P.C.1
  • 12
    • 0344521389 scopus 로고    scopus 로고
    • The histology of human retrieved intervertebral body fusion cages: Good bone graft incorporation and few particles
    • Togawa D, Bauer TW. The histology of human retrieved intervertebral body fusion cages: Good bone graft incorporation and few particles. Trans ORS 2001;655.
    • (2001) Trans ORS , pp. 655
    • Togawa, D.1    Bauer, T.W.2
  • 13
    • 0034432931 scopus 로고    scopus 로고
    • In vitro biomechanical investigation of the stability and stress-shielding effect of lumbar interbody fusion devices
    • Kanayama M, et al. In vitro biomechanical investigation of the stability and stress-shielding effect of lumbar interbody fusion devices. J Neurosurg 2000;93(2 Suppl):259-265.
    • (2000) J Neurosurg , vol.93 , Issue.2 SUPPL. , pp. 259-265
    • Kanayama, M.1
  • 14
    • 0033570287 scopus 로고    scopus 로고
    • Laparoscopic approach to L4-L5 for interbody fusion using BAK cages: Experience in the first 58 cases
    • Regan JJ, Aronoff RJ, Ohnmeiss DD, Sengupta DK. Laparoscopic approach to L4-L5 for interbody fusion using BAK cages: Experience in the first 58 cases. Spine 1999;24:2171-2174.
    • (1999) Spine , vol.24 , pp. 2171-2174
    • Regan, J.J.1    Aronoff, R.J.2    Ohnmeiss, D.D.3    Sengupta, D.K.4
  • 15
    • 0032528898 scopus 로고    scopus 로고
    • Failure of a carbon fiber implant. A case report
    • Tullberg T. Failure of a carbon fiber implant. A case report. Spine 1998;23:1804-1806.
    • (1998) Spine , vol.23 , pp. 1804-1806
    • Tullberg, T.1
  • 16
    • 0033558305 scopus 로고    scopus 로고
    • Laparoscopic fusion of the lumbar spine: Minimally invasive spine surgery. A prospective multicenter study evaluating open and laparoscopic lumbar fusion
    • Regan JJ, Yuan H, McAfee PC. Laparoscopic fusion of the lumbar spine: Minimally invasive spine surgery. A prospective multicenter study evaluating open and laparoscopic lumbar fusion. Spine 1999;24:402-411.
    • (1999) Spine , vol.24 , pp. 402-411
    • Regan, J.J.1    Yuan, H.2    McAfee, P.C.3
  • 17
    • 0000562490 scopus 로고    scopus 로고
    • A quantitative densitometric study investigating the stress-shielding effects of interbody spinal fusion devicesEmphasis on long-term fusions in thoroughbred racehorses
    • New Orleans, LA
    • Cunningham BW, Haggerty CJ, and McAfee PC. A quantitative densitometric study investigating the stress-shielding effects of interbody spinal fusion devicesEmphasis on long-term fusions in thoroughbred racehorses. Presented at the Annual Meeting of the Orthopaedic Research Society, New Orleans, LA, 1998.
    • (1998) Annual Meeting of the Orthopaedic Research Society
    • Cunningham, B.W.1    Haggerty, C.J.2    McAfee, P.C.3
  • 18
    • 2242424899 scopus 로고    scopus 로고
    • Mechanics of absorbable spinal cages perforating the endplates; an in vitro study
    • Smit TH, van Dijk M, Arnoe MF, Wuisman PI. Mechanics of absorbable spinal cages perforating the endplates; an in vitro study. Trans ORS 2000;349.
    • (2000) Trans ORS , pp. 349
    • Smit, T.H.1    Van Dijk, M.2    Arnoe, M.F.3    Wuisman, P.I.4
  • 19
    • 0036534292 scopus 로고    scopus 로고
    • The effect of cage stiffness on the rate of lumbar interbody fusion. An in vivo model using poly(L-lactic acid) and titanium cages
    • van Dijk M, Smit TH, Sugihara S, Burger EH, Wuisman PIJM. The effect of cage stiffness on the rate of lumbar interbody fusion. An in vivo model using poly(L-lactic acid) and titanium cages. Spine 2002;27(7):682-688.
    • (2002) Spine , vol.27 , Issue.7 , pp. 682-688
    • Van Dijk, M.1    Smit, T.H.2    Sugihara, S.3    Burger, E.H.4    Wuisman, P.I.J.M.5
  • 20
    • 0033625225 scopus 로고    scopus 로고
    • Biodegradable implants in fracture fixation: State of the art
    • van der Elst M, Patka P, van der Werken C. Biodegradable implants in fracture fixation: state of the art. Unfallchirurg 2000;103:178-82.
    • (2000) Unfallchirurg , vol.103 , pp. 178-182
    • Van der Elst, M.1    Patka, P.2    Van der Werken, C.3
  • 21
    • 0026587974 scopus 로고
    • Resorbable polyesters: Composition, properties, applications
    • Amecke B, Bendix D, Entenmann G. Resorbable polyesters: Composition, properties, applications. Clin Mater 1992;10:47-50.
    • (1992) Clin Mater , vol.10 , pp. 47-50
    • Amecke, B.1    Bendix, D.2    Entenmann, G.3
  • 22
    • 0035165602 scopus 로고    scopus 로고
    • The fate of resorbable poly-L-lactic/polyglycolic acid (LactoSorb) bone fixation devices in orthognathic surgery
    • Edwards, RC. The fate of resorbable poly-L-lactic/polyglycolic acid (LactoSorb) bone fixation devices in orthognathic surgery. J Oral Maxillofac Surg 2001;59:19-25.
    • (2001) J Oral Maxillofac Surg , vol.59 , pp. 19-25
    • Edwards, R.C.1
  • 23
    • 0033847192 scopus 로고    scopus 로고
    • The future of biodegradable osteosyntheses
    • Cordewener FW. The future of biodegradable osteosyntheses. Tissue Eng 2000;6:413-424.
    • (2000) Tissue Eng , vol.6 , pp. 413-424
    • Cordewener, F.W.1
  • 24
    • 0031780545 scopus 로고    scopus 로고
    • Biodegradable polylactide plates and screws in orthognathic surgery: Technical note
    • Haers PE, Suuronen R, Lindqvist C, Sailer H. Biodegradable polylactide plates and screws in orthognathic surgery: Technical note [see comments]. J Craniomaxillofac Surg 1998;26:87-91.
    • (1998) J Craniomaxillofac Surg , vol.26 , pp. 87-91
    • Haers, P.E.1    Suuronen, R.2    Lindqvist, C.3    Sailer, H.4
  • 26
    • 0343353899 scopus 로고    scopus 로고
    • Bioabsorbable fixation in orthopaedic surgery and traumatology
    • Rokkanen PU. Bioabsorbable fixation in orthopaedic surgery and traumatology. Biomaterials 2000;21:2607-2613.
    • (2000) Biomaterials , vol.21 , pp. 2607-2613
    • Rokkanen, P.U.1
  • 27
    • 0029856691 scopus 로고    scopus 로고
    • In vivo degradation and biocompatability study of in vitro pre-degraded as-polymerized polylactide particles
    • Tunc DC. In vivo degradation and biocompatability study of in vitro pre-degraded as-polymerized polylactide particles. Biomaterials 1996;17:2109-2112.
    • (1996) Biomaterials , vol.17 , pp. 2109-2112
    • Tunc, D.C.1
  • 29
    • 0029120601 scopus 로고
    • Tissue reaction of bioabsorbable ultra high strength poly (L-lactide) rod. A long-term study in rabbits
    • Matsusue Y, Hanafusa S, Yamamuro T, Shikinami Y, Ikada Y. Tissue reaction of bioabsorbable ultra high strength poly (L-lactide) rod. A long-term study in rabbits. Clin Orthop 1995; 317:246-253.
    • (1995) Clin Orthop , vol.317 , pp. 246-253
    • Matsusue, Y.1    Hanafusa, S.2    Yamamuro, T.3    Shikinami, Y.4    Ikada, Y.5
  • 30
    • 0026458592 scopus 로고
    • Absorbable pins of self-reinforced poly-L-lactic acid for fixation of fractures and osteotomies
    • Pihlajamaki H, Bostman O, Hirvensalo E, Tormala P, Rokkanen P. Absorbable pins of self-reinforced poly-L-lactic acid for fixation of fractures and osteotomies. J Bone Joint Surg Br 1992;74:853-857.
    • (1992) J Bone Joint Surg Br , vol.74 , pp. 853-857
    • Pihlajamaki, H.1    Bostman, O.2    Hirvensalo, E.3    Tormala, P.4    Rokkanen, P.5
  • 31
    • 0028363157 scopus 로고
    • Interbody lumbar fusion using a carbon fiber cage implant versus allograft bone. An investigational study in the Spanish goat
    • Brantigan JW et al. Interbody lumbar fusion using a carbon fiber cage implant versus allograft bone. An investigational study in the Spanish goat. Spine 1994;19(13):1436-1444.
    • (1994) Spine , vol.19 , Issue.13 , pp. 1436-1444
    • Brantigan, J.W.1
  • 32
    • 0030008458 scopus 로고    scopus 로고
    • Distractive properties of a threaded interbody fusion device. An in vivo model
    • Sandhu HS et al. Distractive properties of a threaded interbody fusion device. An in vivo model. Spine 1996;21(10):1201-1210.
    • (1996) Spine , vol.21 , Issue.10 , pp. 1201-1210
    • Sandhu, H.S.1
  • 33
    • 0033559935 scopus 로고    scopus 로고
    • Osteogenic protein versus autologous interbody arthrodesis in the sheep thoracic spine. A comparative endoscopic study using the Bagby and Kuslich interbody fusion device
    • Cunningham BW et al. Osteogenic protein versus autologous interbody arthrodesis in the sheep thoracic spine. A comparative endoscopic study using the Bagby and Kuslich interbody fusion device. Spine 1999;24(6):509-518.
    • (1999) Spine , vol.24 , Issue.6 , pp. 509-518
    • Cunningham, B.W.1
  • 34
    • 0036214369 scopus 로고    scopus 로고
    • The use of a quadruped as an in vivo model for the study of the spine - Biomechanical considerations
    • Smit TH. The use of a quadruped as an in vivo model for the study of the spine - Biomechanical considerations. Eur Spine J 2002;11(2):137-144.
    • (2002) Eur Spine J , vol.11 , Issue.2 , pp. 137-144
    • Smit, T.H.1
  • 35
    • 0034667302 scopus 로고    scopus 로고
    • Real-time in vivo loading in the lumbar spine: Part 1. Interbody implant: Load cell design and preliminary results
    • Ledet EH, Sachs BL, Brunski JB, Gatto CE, Donzelli PS. Real-time in vivo loading in the lumbar spine: Part 1. Interbody implant: Load cell design and preliminary results. Spine 2000; 25:2595-2600.
    • (2000) Spine , vol.25 , pp. 2595-2600
    • Ledet, E.H.1    Sachs, B.L.2    Brunski, J.B.3    Gatto, C.E.4    Donzelli, P.S.5
  • 36
    • 0021911398 scopus 로고
    • Biomechanics of lumbar fusion
    • Evans JH. Biomechanics of lumbar fusion. Clin Orthop 1985; 193:38-46.
    • (1985) Clin Orthop , vol.193 , pp. 38-46
    • Evans, J.H.1
  • 37
    • 0033952719 scopus 로고    scopus 로고
    • Posterolateral and anterior interbody spinal fusion models in the sheep
    • Steffen T, Marchesi D, Aebi M. Posterolateral and anterior interbody spinal fusion models in the sheep. Clin Orthop 2000; 371:28-37.
    • (2000) Clin Orthop , vol.371 , pp. 28-37
    • Steffen, T.1    Marchesi, D.2    Aebi, M.3
  • 38
    • 0027703781 scopus 로고
    • Mechanisms of polymer degradation in implantable devices. 2. Poly(DL-lactic acid)
    • Ali SA, Doherty PJ, Williams DF. Mechanisms of polymer degradation in implantable devices. 2. Poly(DL-lactic acid). J Biomed Mater Res 1993;27:1409-1418.
    • (1993) J Biomed Mater Res , vol.27 , pp. 1409-1418
    • Ali, S.A.1    Doherty, P.J.2    Williams, D.F.3
  • 39
    • 0026603824 scopus 로고
    • Mechanisms of biodegradation of implantable polymers
    • Williams DF. Mechanisms of biodegradation of implantable polymers. Clin Mater 1992;10:9-12.
    • (1992) Clin Mater , vol.10 , pp. 9-12
    • Williams, D.F.1
  • 40
    • 0031554923 scopus 로고    scopus 로고
    • Effect of in vivo and in vitro degradation on molecular and mechanical properties of various low-molecular-weight polylactides
    • Mainil-Varlet P, Curtis R, Gogolewski S. Effect of in vivo and in vitro degradation on molecular and mechanical properties of various low-molecular-weight polylactides. J Biomed Mater Res 1997;36:360-380.
    • (1997) J Biomed Mater Res , vol.36 , pp. 360-380
    • Mainil-Varlet, P.1    Curtis, R.2    Gogolewski, S.3
  • 41
    • 0027572376 scopus 로고
    • Poly(L-lactide): A long-term degradation study in vivo. Part III. Analytical characterization
    • Pistner H, Bendix DR, Muhling J, Reuther JF. Poly(L-lactide): A long-term degradation study in vivo. Part III. Analytical characterization. Biomaterials 1993;14:291-298.
    • (1993) Biomaterials , vol.14 , pp. 291-298
    • Pistner, H.1    Bendix, D.R.2    Muhling, J.3    Reuther, J.F.4
  • 42
    • 0023839310 scopus 로고
    • A comparative scanning electron microscopic study on degradation of absorbable ligating clips in vivo and in vitro
    • Chegini N, Hay DL, von Fraunhofer JA, Masterson BJ. A comparative scanning electron microscopic study on degradation of absorbable ligating clips in vivo and in vitro. J Biomed Mater Res 1988;22:71-79.
    • (1988) J Biomed Mater Res , vol.22 , pp. 71-79
    • Chegini, N.1    Hay, D.L.2    Von Fraunhofer, J.A.3    Masterson, B.J.4
  • 43
  • 44
    • 0033754981 scopus 로고    scopus 로고
    • The efficacy of bioresorbable fixation in the repair of mandibular fractures: An animal study
    • Quereshy FA, Goldstein JA, Goldberg JS, Beg Z. The efficacy of bioresorbable fixation in the repair of mandibular fractures: An animal study. J Oral Maxillofac Surg 2000;58:1263-1269.
    • (2000) J Oral Maxillofac Surg , vol.58 , pp. 1263-1269
    • Quereshy, F.A.1    Goldstein, J.A.2    Goldberg, J.S.3    Beg, Z.4
  • 45


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.