메뉴 건너뛰기




Volumn 41, Issue 11, 2006, Pages 799-805

3 T contrast-enhanced magnetic resonance angiography for evaluation of the intracranial arteries: Comparison with time-of-flight magnetic resonance angiography and multislice computed tomography angiography

Author keywords

CT angiography; High magnetic field or 3 T; Intracranial arteries; MR angiography; Parallel acquisition

Indexed keywords

ADULT; AGED; ARTERY DIAMETER; ARTICLE; BRAIN ARTERY; CEREBROVASCULAR DISEASE; CLINICAL ARTICLE; CONTRAST ENHANCED MAGNETIC RESONANCE ANGIOGRAPHY; CONTRAST ENHANCEMENT; DIAGNOSTIC ACCURACY; DIAGNOSTIC PROCEDURE; EVALUATION; FEMALE; HUMAN; IMAGE ANALYSIS; IMAGE QUALITY; MAGNETIC RESONANCE ANGIOGRAPHY; MALE; MEASUREMENT; MULTISLICE COMPUTED TOMOGRAPHY ANGIOGRAPHY; POSTERIOR COMMUNICATING ARTERY; PRIORITY JOURNAL; PROSPECTIVE STUDY; RADIOLOGIST; STATISTICAL ANALYSIS; THREE DIMENSIONAL IMAGING; TIME OF FLIGHT MAGNETIC RESONANCE ANGIOGRAPHY;

EID: 33749829648     PISSN: 00209996     EISSN: None     Source Type: Journal    
DOI: 10.1097/01.rli.0000242835.00032.f5     Document Type: Article
Times cited : (54)

References (40)
  • 1
    • 0025138979 scopus 로고
    • Cerebral angiographic risk in mild cerebrovascular disease
    • Hankey GJ, Warlow CP, Sellar RJ. Cerebral angiographic risk in mild cerebrovascular disease. Stroke. 1990;21:209-222.
    • (1990) Stroke , vol.21 , pp. 209-222
    • Hankey, G.J.1    Warlow, C.P.2    Sellar, R.J.3
  • 2
    • 0027968453 scopus 로고
    • Neurologic complications of cerebral angiography
    • discussion 1408-1411
    • Heiserman JE, Dean BL, Hodak JA, et al. Neurologic complications of cerebral angiography. AJNR Am J Neuroradiol. 1994;15:1401-1407; discussion 1408-1411.
    • (1994) AJNR Am J Neuroradiol , vol.15 , pp. 1401-1407
    • Heiserman, J.E.1    Dean, B.L.2    Hodak, J.A.3
  • 3
    • 0036678522 scopus 로고    scopus 로고
    • Detection and characterization of very small cerebral aneurysms by using 2D and 3D helical CT angiography
    • Villablanca JP, Jahan R, Hooshi P, et al. Detection and characterization of very small cerebral aneurysms by using 2D and 3D helical CT angiography. AJNR Am J Neuroradiol. 2002;23:1187-1198.
    • (2002) AJNR Am J Neuroradiol , vol.23 , pp. 1187-1198
    • Villablanca, J.P.1    Jahan, R.2    Hooshi, P.3
  • 4
    • 16644378238 scopus 로고    scopus 로고
    • Multi-section CT angiography for detection of cerebral aneurysms
    • Teksam M, McKinney A, Casey S, et al. Multi-section CT angiography for detection of cerebral aneurysms. AJNR Am J Neuroradiol. 2004;25:1485-1492.
    • (2004) AJNR Am J Neuroradiol , vol.25 , pp. 1485-1492
    • Teksam, M.1    McKinney, A.2    Casey, S.3
  • 5
    • 1642540062 scopus 로고    scopus 로고
    • Detection of intracranial aneurysms: Multi-detector row CT angiography compared with DSA
    • Jayaraman MV, Mayo-Smith WW, Tung GA, et al. Detection of intracranial aneurysms: multi-detector row CT angiography compared with DSA. Radiology. 2004;230:510-518.
    • (2004) Radiology , vol.230 , pp. 510-518
    • Jayaraman, M.V.1    Mayo-Smith, W.W.2    Tung, G.A.3
  • 6
    • 0031660607 scopus 로고    scopus 로고
    • Intracranial vascular stenosis and occlusion: Comparison of 3D time-of-flight and 3D phase-contrast MR angiography
    • Oelerich M, Lentschig MG, Zunker P, et al. Intracranial vascular stenosis and occlusion: comparison of 3D time-of-flight and 3D phase-contrast MR angiography. Neuroradiology. 1998;40:567-573.
    • (1998) Neuroradiology , vol.40 , pp. 567-573
    • Oelerich, M.1    Lentschig, M.G.2    Zunker, P.3
  • 7
    • 0029118567 scopus 로고
    • High resolution, magnetization transfer saturation, variable flip angle, time-of-flight MRA in the detection of intracranial vascular stenoses
    • Dagirmanjian A, Ross JS, Obuchowski N, et al. High resolution, magnetization transfer saturation, variable flip angle, time-of-flight MRA in the detection of intracranial vascular stenoses. J Comput Assist Tomogr. 1995;19:700-706.
    • (1995) J Comput Assist Tomogr , vol.19 , pp. 700-706
    • Dagirmanjian, A.1    Ross, J.S.2    Obuchowski, N.3
  • 8
    • 0028916736 scopus 로고
    • Intracranial aneurysms: MR angiographic screening in 400 asymptomatic individuals with increased familial risk
    • Ronkainen A, Puranen MI, Hernesniemi JA, et al. Intracranial aneurysms: MR angiographic screening in 400 asymptomatic individuals with increased familial risk. Radiology. 1995;195:35-40.
    • (1995) Radiology , vol.195 , pp. 35-40
    • Ronkainen, A.1    Puranen, M.I.2    Hernesniemi, J.A.3
  • 9
    • 0028946421 scopus 로고
    • Intracranial arteries: Prospective blinded comparative study of MR angiography and DSA in 50 patients
    • Stock KW, Radue EW, Jacob AL, et al. Intracranial arteries: prospective blinded comparative study of MR angiography and DSA in 50 patients. Radiology. 1995;195:451-456.
    • (1995) Radiology , vol.195 , pp. 451-456
    • Stock, K.W.1    Radue, E.W.2    Jacob, A.L.3
  • 10
    • 0033735394 scopus 로고    scopus 로고
    • Can noninvasive imaging accurately depict intracranial aneurysms? A systematic review
    • White PM, Wardlaw JM, Easton V. Can noninvasive imaging accurately depict intracranial aneurysms? A systematic review. Radiology. 2000;217:361-370.
    • (2000) Radiology , vol.217 , pp. 361-370
    • White, P.M.1    Wardlaw, J.M.2    Easton, V.3
  • 11
    • 16844383422 scopus 로고    scopus 로고
    • Intracranial aneurysms treated with Guglielmi detachable coils: Usefulness of 6-month imaging follow-up with contrast-enhanced MR angiography
    • Gauvrit JY, Leclerc X, Pernodet M, et al. Intracranial aneurysms treated with Guglielmi detachable coils: usefulness of 6-month imaging follow-up with contrast-enhanced MR angiography. AJNR Am J Neuroradiol. 2005;26:515-521.
    • (2005) AJNR Am J Neuroradiol , vol.26 , pp. 515-521
    • Gauvrit, J.Y.1    Leclerc, X.2    Pernodet, M.3
  • 12
    • 0033730701 scopus 로고    scopus 로고
    • Contrast-enhanced MR angiography of intracranial giant aneurysms
    • Jager HR, Ellamushi H, Moore EA, et al. Contrast-enhanced MR angiography of intracranial giant aneurysms. AJNR Am J Neuroradiol. 2000;21:1900-1907.
    • (2000) AJNR Am J Neuroradiol , vol.21 , pp. 1900-1907
    • Jager, H.R.1    Ellamushi, H.2    Moore, E.A.3
  • 13
    • 0033917305 scopus 로고    scopus 로고
    • Intracranial aneurysms: Detection with gadolinium-enhanced dynamic three-dimensional MR angiography - Initial results
    • Metens T, Rio F, Baleriaux D, et al. Intracranial aneurysms: detection with gadolinium-enhanced dynamic three-dimensional MR angiography - initial results. Radiology. 2000;216:39-46.
    • (2000) Radiology , vol.216 , pp. 39-46
    • Metens, T.1    Rio, F.2    Baleriaux, D.3
  • 14
    • 0036939518 scopus 로고    scopus 로고
    • Contrast-enhanced MR angiography (enhanced 3-D fast gradient echo) for diagnosis of cerebral aneurysms
    • Suzuki IM, Matsui Ueda F, et al. Contrast-enhanced MR angiography (enhanced 3-D fast gradient echo) for diagnosis of cerebral aneurysms. Neuroradiology. 2002;44:17-20.
    • (2002) Neuroradiology , vol.44 , pp. 17-20
    • Suzuki, I.M.1    Matsui Ueda, F.2
  • 15
    • 0034041554 scopus 로고    scopus 로고
    • Contrast-enhanced MR angiography of supraaortic vessels: The effect of voxel size on image quality
    • Leclerc X, Nicol L, Gauvrit JY, et al. Contrast-enhanced MR angiography of supraaortic vessels: the effect of voxel size on image quality. AJNR Am J Neuroradiol. 2000;21:1021-1027.
    • (2000) AJNR Am J Neuroradiol , vol.21 , pp. 1021-1027
    • Leclerc, X.1    Nicol, L.2    Gauvrit, J.Y.3
  • 16
    • 0030982409 scopus 로고    scopus 로고
    • Simultaneous acquisition of spatial harmonics (SMASH): Fast imaging with radiofrequency coil arrays
    • Sodickson DK, Manning WJ. Simultaneous acquisition of spatial harmonics (SMASH): fast imaging with radiofrequency coil arrays. Magn Reson Med. 1997;38:591-603.
    • (1997) Magn Reson Med , vol.38 , pp. 591-603
    • Sodickson, D.K.1    Manning, W.J.2
  • 18
    • 0036263907 scopus 로고    scopus 로고
    • Generalized autocalibrating partially parallel acquisitions (GRAPPA)
    • Griswold MA, Jakob PM, Heidemann RM, et al. Generalized autocalibrating partially parallel acquisitions (GRAPPA). Magn Reson Med. 2002;47:1202-1210.
    • (2002) Magn Reson Med , vol.47 , pp. 1202-1210
    • Griswold, M.A.1    Jakob, P.M.2    Heidemann, R.M.3
  • 19
    • 1642541669 scopus 로고    scopus 로고
    • Improved image quality of intracranial aneurysms: 3.0-T versus 1.5-T time-of-flight MR angiography
    • Gibbs GF, Huston J 3rd, Bernstein MA, et al. Improved image quality of intracranial aneurysms: 3.0-T versus 1.5-T time-of-flight MR angiography. AJNR Am J Neuroradiol. 2004;25:84-87.
    • (2004) AJNR Am J Neuroradiol , vol.25 , pp. 84-87
    • Gibbs, G.F.1    Huston III, J.2    Bernstein, M.A.3
  • 20
    • 33646353706 scopus 로고    scopus 로고
    • Time-resolved contrast enhanced magnetic resonance angiography of the head and neck at 3.0 Tesla: Initial results
    • Nael K, Michaely JH, Villablanca P, et al. Time-resolved contrast enhanced magnetic resonance angiography of the head and neck at 3.0 Tesla: initial results. Invest Radiol. 2006;41:116-124.
    • (2006) Invest Radiol , vol.41 , pp. 116-124
    • Nael, K.1    Michaely, J.H.2    Villablanca, P.3
  • 21
    • 33746384612 scopus 로고    scopus 로고
    • High spatial-resolution CE-MRA of the carotid circulation with parallel imaging: Comparison of image quality between 2 different acceleration factors at 3.0 Tesla
    • Nael K, Ruehm SG, Michaely HJ, et al. High spatial-resolution CE-MRA of the carotid circulation with parallel imaging: comparison of image quality between 2 different acceleration factors at 3.0 Tesla. Invest Radiol. 2006;41:391-399.
    • (2006) Invest Radiol , vol.41 , pp. 391-399
    • Nael, K.1    Ruehm, S.G.2    Michaely, H.J.3
  • 22
    • 0942297923 scopus 로고    scopus 로고
    • Sensitivity encoding (SENSE) for high spatial resolution time-of-flight MR angiography of the intracranial arteries at 3.0 T
    • Willinek WA, Gieseke J, von Falkenhausen M, et al. Sensitivity encoding (SENSE) for high spatial resolution time-of-flight MR angiography of the intracranial arteries at 3.0 T. Rofo. 2004;176:21-26.
    • (2004) Rofo , vol.176 , pp. 21-26
    • Willinek, W.A.1    Gieseke, J.2    Von Falkenhausen, M.3
  • 23
    • 33749818786 scopus 로고    scopus 로고
    • Contrast-enhanced MR angiography of the supra-aortic arteries at 3.0 Tesla: Highly parallel acquisition for improved spatial resolution over an extended field of view
    • In press
    • Nael K, Villablanca J, Pope W, et al. Contrast-enhanced MR angiography of the supra-aortic arteries at 3.0 Tesla: highly parallel acquisition for improved spatial resolution over an extended field of view. Radiology. In press.
    • Radiology
    • Nael, K.1    Villablanca, J.2    Pope, W.3
  • 24
    • 84908219488 scopus 로고
    • Statistical methods for assessing agreement between two methods of clinical measurement
    • Bland JM, Altman DG. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet. 1986;1:307-310.
    • (1986) Lancet , vol.1 , pp. 307-310
    • Bland, J.M.1    Altman, D.G.2
  • 25
    • 33749843313 scopus 로고    scopus 로고
    • Detection and quantitation of small intracranial arteries using multidetector helical CT angiography: Comparison to conventional catheter angiography
    • In press
    • Villablanca JP, Rodriguez F, Stockmann T, et al. Detection and quantitation of small intracranial arteries using multidetector helical CT angiography: comparison to conventional catheter angiography. AJR Am J Roentgenol. In press.
    • AJR Am J Roentgenol
    • Villablanca, J.P.1    Rodriguez, F.2    Stockmann, T.3
  • 26
    • 0035008939 scopus 로고    scopus 로고
    • Intracranial aneurysms: CT angiography and MR angiography for detection prospective blinded comparison in a large patient cohort
    • White PM, Teasdale EM, Wardlaw JM, et al. Intracranial aneurysms: CT angiography and MR angiography for detection prospective blinded comparison in a large patient cohort. Radiology. 2001;219:739-749.
    • (2001) Radiology , vol.219 , pp. 739-749
    • White, P.M.1    Teasdale, E.M.2    Wardlaw, J.M.3
  • 27
    • 0345015505 scopus 로고    scopus 로고
    • Time-of-flight MR angiography: Comparison of 3.0-T imaging and 1.5-T imaging - Initial experience
    • Willinek WA, Born M, Simon B, et al. Time-of-flight MR angiography: comparison of 3.0-T imaging and 1.5-T imaging - initial experience. Radiology. 2003;229:913-920.
    • (2003) Radiology , vol.229 , pp. 913-920
    • Willinek, W.A.1    Born, M.2    Simon, B.3
  • 28
    • 0034467481 scopus 로고    scopus 로고
    • MRA of intracranial aneurysm models: A comparison of contrast-enhanced three-dimensional MRA with time-of-flight MRA
    • Isoda H, Takehara Y, Isogai S, et al. MRA of intracranial aneurysm models: a comparison of contrast-enhanced three-dimensional MRA with time-of-flight MRA. J Comput Assist Tomogr. 2000;24:308-315.
    • (2000) J Comput Assist Tomogr , vol.24 , pp. 308-315
    • Isoda, H.1    Takehara, Y.2    Isogai, S.3
  • 29
    • 0027439656 scopus 로고
    • Intracranial MR angiography: Application of magnetization transfer contrast and fat saturation to short gradient-echo, velocity-compensated sequences
    • Lin W, Tkach JA, Haacke EM, et al. Intracranial MR angiography: application of magnetization transfer contrast and fat saturation to short gradient-echo, velocity-compensated sequences. Radiology. 1993;186:753-761.
    • (1993) Radiology , vol.186 , pp. 753-761
    • Lin, W.1    Tkach, J.A.2    Haacke, E.M.3
  • 30
    • 28444484539 scopus 로고    scopus 로고
    • Intracranial vascular stenosis and occlusive disease: Evaluation with CT angiography, MR angiography, and digital subtraction angiography
    • Bash S, Villablanca JP, Jahan R, et al. Intracranial vascular stenosis and occlusive disease: evaluation with CT angiography, MR angiography, and digital subtraction angiography. AJNR Am J Neuroradiol. 2005;26:1012-1021.
    • (2005) AJNR Am J Neuroradiol , vol.26 , pp. 1012-1021
    • Bash, S.1    Villablanca, J.P.2    Jahan, R.3
  • 31
    • 23944488753 scopus 로고    scopus 로고
    • Patient radiation doses for electron beam CT
    • Castellano IA, Dance DR, Skinner CL, et al. Patient radiation doses for electron beam CT. Med Phys. 2005;32:2517-2527.
    • (2005) Med Phys , vol.32 , pp. 2517-2527
    • Castellano, I.A.1    Dance, D.R.2    Skinner, C.L.3
  • 32
    • 0029763248 scopus 로고    scopus 로고
    • Improved centric phase encoding orders for three-dimensional magnetization-prepared MR angiography
    • Wilman AH, Riederer SJ. Improved centric phase encoding orders for three-dimensional magnetization-prepared MR angiography. Magn Reson Med. 1996;36:384-392.
    • (1996) Magn Reson Med , vol.36 , pp. 384-392
    • Wilman, A.H.1    Riederer, S.J.2
  • 33
    • 0030705199 scopus 로고    scopus 로고
    • Performance of an elliptical centric view order for signal enhancement and motion artifact suppression in breath-hold three-dimensional gradient echo imaging
    • Wilman AH, Riederer SJ. Performance of an elliptical centric view order for signal enhancement and motion artifact suppression in breath-hold three-dimensional gradient echo imaging. Magn Reson Med. 1997;38:793-802.
    • (1997) Magn Reson Med , vol.38 , pp. 793-802
    • Wilman, A.H.1    Riederer, S.J.2
  • 34
    • 0030770299 scopus 로고    scopus 로고
    • Fluoroscopically triggered contrast-enhanced three-dimensional MR angiography with elliptical centric view order: Application to the renal arteries
    • Wilman AH, Riederer SJ, King BF, et al. Fluoroscopically triggered contrast-enhanced three-dimensional MR angiography with elliptical centric view order: application to the renal arteries. Radiology. 1997;205:137-146.
    • (1997) Radiology , vol.205 , pp. 137-146
    • Wilman, A.H.1    Riederer, S.J.2    King, B.F.3
  • 35
    • 0036829410 scopus 로고    scopus 로고
    • Randomly segmented central k-space ordering in high-spatial-resolution contrast-enhanced MR angiography of the supraaortic arteries: Initial experience
    • Willinek WA, Gieseke J, Conrad R, et al. Randomly segmented central k-space ordering in high-spatial-resolution contrast-enhanced MR angiography of the supraaortic arteries: initial experience. Radiology. 2002;225:583-588.
    • (2002) Radiology , vol.225 , pp. 583-588
    • Willinek, W.A.1    Gieseke, J.2    Conrad, R.3
  • 36
    • 5044228868 scopus 로고    scopus 로고
    • Parallel imaging at high field strength: Synergies and joint potential
    • Pruessmann KP. Parallel imaging at high field strength: synergies and joint potential. Top Magn Reson Imaging. 2004;15:237-244.
    • (2004) Top Magn Reson Imaging , vol.15 , pp. 237-244
    • Pruessmann, K.P.1
  • 37
    • 0036099935 scopus 로고    scopus 로고
    • Vessel contrast at three Tesla in time-of-flight magnetic resonance angiography of the intracranial and carotid arteries
    • Al-Kwifi O, Emery DJ, Wilman AH. Vessel contrast at three Tesla in time-of-flight magnetic resonance angiography of the intracranial and carotid arteries. Magn Reson Imaging. 2002;20:181-187.
    • (2002) Magn Reson Imaging , vol.20 , pp. 181-187
    • Al-Kwifi, O.1    Emery, D.J.2    Wilman, A.H.3
  • 38
    • 33646379879 scopus 로고    scopus 로고
    • Effect of field strengths on magnetic resonance angiography: Comparison of an ultrasmall superparamagnetic iron oxide blood-pool contrast agent and gadopentetate dimeglumine in rabbits at 1.5 and 3.0 Tesla
    • Allkemper T, Heindel W, Kooijman H, et al. Effect of field strengths on magnetic resonance angiography: comparison of an ultrasmall superparamagnetic iron oxide blood-pool contrast agent and gadopentetate dimeglumine in rabbits at 1.5 and 3.0 Tesla. Invest Radiol. 2006;41:97-104.
    • (2006) Invest Radiol , vol.41 , pp. 97-104
    • Allkemper, T.1    Heindel, W.2    Kooijman, H.3
  • 39
    • 33745686046 scopus 로고    scopus 로고
    • High-resolution renal MRA: Comparison of image quality and vessel depiction with different parallel imaging acceleration factors
    • Michaely HJ, Herrmann KA, Kramer H, et al. High-resolution renal MRA: comparison of image quality and vessel depiction with different parallel imaging acceleration factors. J Magn Reson Imaging. 2006;24:95-100.
    • (2006) J Magn Reson Imaging , vol.24 , pp. 95-100
    • Michaely, H.J.1    Herrmann, K.A.2    Kramer, H.3
  • 40
    • 1342302257 scopus 로고    scopus 로고
    • Contrast-enhanced three-dimensional pulmonary perfusion magnetic resonance imaging: Intraindividual comparison of 1.0 M gadobutrol and 0.5 M Gd-DTPA at three dose levels
    • Fink C, Puderbach M, Ley S, et al. Contrast-enhanced three-dimensional pulmonary perfusion magnetic resonance imaging: intraindividual comparison of 1.0 M gadobutrol and 0.5 M Gd-DTPA at three dose levels. Invest Radiol. 2004;39:143-148.
    • (2004) Invest Radiol , vol.39 , pp. 143-148
    • Fink, C.1    Puderbach, M.2    Ley, S.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.