메뉴 건너뛰기




Volumn 119, Issue 1-4, 2006, Pages 483-486

Determination of LiF:Mg,Ti and LiF:Mg,Cu,P TL efficiency for X-rays and their application to Monte Carlo simulations of dosemeter response

Author keywords

[No Author keywords available]

Indexed keywords

CESIUM 137; COBALT 60; COPPER; LITHIUM FLUORIDE; MAGNESIUM; PHOSPHORUS; TITANIUM;

EID: 33749665587     PISSN: 01448420     EISSN: None     Source Type: Journal    
DOI: 10.1093/rpd/ncj001     Document Type: Article
Times cited : (16)

References (11)
  • 1
    • 0032794348 scopus 로고    scopus 로고
    • Modelling of the thermoluminescence response of LiF: Mg,Cu, P (MCP-N) detectors after doses of low energy photons
    • Olko, P., Bilski, P., Budzanowski, M., Waligorski, M. P. R., Fasso, A. and Ipe, N. Modelling of the thermoluminescence response of LiF: Mg,Cu, P (MCP-N) detectors after doses of low energy photons. Radiat. Prot. Dosim. 84(1-4), 103-108 (1999).
    • (1999) Radiat. Prot. Dosim. , vol.84 , Issue.1-4 , pp. 103-108
    • Olko, P.1    Bilski, P.2    Budzanowski, M.3    Waligorski, M.P.R.4    Fasso, A.5    Ipe, N.6
  • 2
    • 0029793320 scopus 로고    scopus 로고
    • Microdosimetric interpretation of thermoluminescence efficiencies of LiF: Mg, Cu, P (MCP-N) detectors for weakly and densly ionising radiation
    • Olko, P. Microdosimetric interpretation of thermoluminescence efficiencies of LiF: Mg, Cu, P (MCP-N) detectors for weakly and densly ionising radiation. Radiat. Prot. Dosim. 65(1-4), 151-158 (1996).
    • (1996) Radiat. Prot. Dosim. , vol.65 , Issue.1-4 , pp. 151-158
    • Olko, P.1
  • 3
    • 0036387863 scopus 로고    scopus 로고
    • Microdosimetric interpretation of the photon energy response of-LiF: Mg,Ti detectors
    • Olko, P., Bilski, P. and Kim, J.-L. Microdosimetric interpretation of the photon energy response of-LiF: Mg,Ti detectors. Radiat. Prot. Dosim. 100(1-4), 119-122 (2002).
    • (2002) Radiat. Prot. Dosim. , vol.100 , Issue.1-4 , pp. 119-122
    • Olko, P.1    Bilski, P.2    Kim, J.-L.3
  • 4
    • 0003653711 scopus 로고    scopus 로고
    • X and gamma reference radiations for calibrating dosemeters and doserate meters and for determining their response as a function of photon energy - Part 3: Calibration of area and personal dosemeters and the measurement of their response as a function of energy and angle of incidence
    • International Organization for Standardization. ISO 4037-3 (Geneva: ISO)
    • International Organization for Standardization. X and gamma reference radiations for calibrating dosemeters and doserate meters and for determining their response as a function of photon energy - Part 3: Calibration of area and personal dosemeters and the measurement of their response as a function of energy and angle of incidence. ISO 4037-3 (Geneva: ISO) (1999).
    • (1999)
  • 5
    • 0036390665 scopus 로고    scopus 로고
    • The use of Monte Carlo simulation technique for the design of an H*(10) dosemeter based on TLD-100
    • Hranitzky, C., Stadtmann, H. and Kindl, P. The use of Monte Carlo simulation technique for the design of an H*(10) dosemeter based on TLD-100. Radiat. Prot. Dosim. 101(1-4), 279-282 (2002).
    • (2002) Radiat. Prot. Dosim. , vol.101 , Issue.1-4 , pp. 279-282
    • Hranitzky, C.1    Stadtmann, H.2    Kindl, P.3
  • 6
    • 33749656842 scopus 로고    scopus 로고
    • Development of a thermoluminescence based area dosemeter for determining the ambient dose equivalent H* (10) in photon radiation fields
    • Doctoral thesis (in German), Technical University of Graz, Austria
    • Hranitzky, C. Development of a thermoluminescence based area dosemeter for determining the ambient dose equivalent H* (10) in photon radiation fields. Doctoral thesis (in German), Technical University of Graz, Austria (2002).
    • (2002)
    • Hranitzky, C.1
  • 7
    • 33749663913 scopus 로고    scopus 로고
    • Microdosimetric Modelling of Physical and Biological Detectors
    • Habilitation thesis, Institute of Nuclear Physics, Krakow, Poland
    • Olko, P. Microdosimetric modelling of physical and biological detectors. Habilitation thesis, Institute of Nuclear Physics, Krakow, Poland (2002).
    • (2002)
    • Olko, P.1
  • 10
    • 0033064278 scopus 로고    scopus 로고
    • The average distance between Mg-based trapping structures in LiF:Mg, Ti and LiF: Mg, Cu, P and the relevance to microdosimetry
    • Horowitz, Y. S. The average distance between Mg-based trapping structures in LiF:MG, Ti and LiF: Mg, Cu, P and the relevance to microdosimetry. Radiat. Prot. Dosim. 82(1), 51-54 (1999).
    • (1999) Radiat. Prot. Dosim. , vol.82 , Issue.1 , pp. 51-54
    • Horowitz, Y.S.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.