메뉴 건너뛰기




Volumn 24, Issue 4, 2006, Pages 922-927

Dynamic MR venography: An intrinsic benefit of time-resolved MR angiography

Author keywords

Contrast enhancement; Dynamic imaging; Magnetic resonance (MR); Peripheral vasculature; Venography

Indexed keywords

ALGORITHM; ARTERY DISEASE; ARTICLE; CLINICAL ARTICLE; CONTRAST ARRIVAL TIME; CONTRAST ENHANCEMENT; DYNAMIC CONTRAST ENHANCED MAGNETIC RESONANCE VENOGRAPHY; EVALUATION; HUMAN; IMAGE ENHANCEMENT; IMAGE PROCESSING; IMAGE RECONSTRUCTION; LEG PHLEBOGRAPHY; MAGNETIC RESONANCE ANGIOGRAPHY; MEASUREMENT; PHLEBOGRAPHY; PRIORITY JOURNAL; PROJECTION RECONSTRUCTION; QUANTITATIVE ANALYSIS; RADIOLOGICAL PARAMETERS; SIGNAL NOISE RATIO; SIGNAL PROCESSING; TECHNIQUE; TIME; VEIN DISEASE;

EID: 33749625613     PISSN: 10531807     EISSN: 15222586     Source Type: Journal    
DOI: 10.1002/jmri.20716     Document Type: Article
Times cited : (22)

References (20)
  • 1
    • 0025891903 scopus 로고
    • A population-based perspective of the hospital incidence and case-fatality rates of deep vein thrombosis and pulmonary embolism. The Worcester DVT study
    • Anderson FA, Wheeler HB, Goldberg RJ, et al. A population-based perspective of the hospital incidence and case-fatality rates of deep vein thrombosis and pulmonary embolism. The Worcester DVT study. Arch Intern Med 1991;151:933-938.
    • (1991) Arch Intern Med , vol.151 , pp. 933-938
    • Anderson, F.A.1    Wheeler, H.B.2    Goldberg, R.J.3
  • 2
    • 0023948465 scopus 로고
    • Deep venous thrombosis: Is contrast venography still the diagnostic "gold standard"?
    • Redman HC. Deep venous thrombosis: is contrast venography still the diagnostic "gold standard"? Radiology 1988;168:277-278.
    • (1988) Radiology , vol.168 , pp. 277-278
    • Redman, H.C.1
  • 4
    • 0029682454 scopus 로고    scopus 로고
    • Detection of deep venous thrombosis: Prospective comparison of MR imaging and sonography
    • Evans AJ, Sostman HD, Witty LA, et al. Detection of deep venous thrombosis: prospective comparison of MR imaging and sonography. J Magn Reson Imaging 1996;1:44-51.
    • (1996) J Magn Reson Imaging , vol.1 , pp. 44-51
    • Evans, A.J.1    Sostman, H.D.2    Witty, L.A.3
  • 6
    • 0025118539 scopus 로고
    • Deep venous thrombosis: Experience with gradient-echo MR imaging in 66 patients
    • Spritzer CE, Sostman HD, Wilkes DC, Coleman E. Deep venous thrombosis: experience with gradient-echo MR imaging in 66 patients. Radiology 1990;177:235-241.
    • (1990) Radiology , vol.177 , pp. 235-241
    • Spritzer, C.E.1    Sostman, H.D.2    Wilkes, D.C.3    Coleman, E.4
  • 7
    • 0025745302 scopus 로고
    • Sequential 2D inflow venography: Initial clinical observations
    • Lanzer P, Gross G, Keller F, Pohost G. Sequential 2D inflow venography: initial clinical observations. Magn Reson Med 1991;19:470-476.
    • (1991) Magn Reson Med , vol.19 , pp. 470-476
    • Lanzer, P.1    Gross, G.2    Keller, F.3    Pohost, G.4
  • 8
    • 0030040199 scopus 로고    scopus 로고
    • MR venography of the calf: Value of flow-enhanced time-of-flight echoplanar imaging
    • Holtz DJ, Debatin JF, McKinnon GC, et al. MR venography of the calf: value of flow-enhanced time-of-flight echoplanar imaging. AJR Am J Roentgenol 1996;166:663-668.
    • (1996) AJR Am J Roentgenol , vol.166 , pp. 663-668
    • Holtz, D.J.1    Debatin, J.F.2    McKinnon, G.C.3
  • 11
    • 0034111614 scopus 로고    scopus 로고
    • Pelvic and lower extremity veins: Contrast-enhanced three-dimensional MR venography with a dedicated vascular coil-initial experience
    • Ruehm SG, Wiesner W, Debatin JF. Pelvic and lower extremity veins: contrast-enhanced three-dimensional MR venography with a dedicated vascular coil-initial experience. Radiology 2000;215:421-427.
    • (2000) Radiology , vol.215 , pp. 421-427
    • Ruehm, S.G.1    Wiesner, W.2    Debatin, J.F.3
  • 13
    • 0037371628 scopus 로고    scopus 로고
    • Deep venous thrombosis: Diagnosis by using venous enhanced subtracted peak arterial MR venography versus conventional venography
    • Fraser DGW, Moody AR, Davidson IR, Martel AL, Morgan PS. Deep venous thrombosis: diagnosis by using venous enhanced subtracted peak arterial MR venography versus conventional venography. Radiology 2003;226:812-820.
    • (2003) Radiology , vol.226 , pp. 812-820
    • Fraser, D.G.W.1    Moody, A.R.2    Davidson, I.R.3    Martel, A.L.4    Morgan, P.S.5
  • 14
    • 0037406526 scopus 로고    scopus 로고
    • Separating arterial and venous components from 3D dynamic contrast-enhanced MRI studies using factor analysis
    • Martel AL, Fraser DGW, Delay GS, Morgan PS, Moody AR. Separating arterial and venous components from 3D dynamic contrast-enhanced MRI studies using factor analysis. Magn Reson Med 2003;49:928-933.
    • (2003) Magn Reson Med , vol.49 , pp. 928-933
    • Martel, A.L.1    Fraser, D.G.W.2    Delay, G.S.3    Morgan, P.S.4    Moody, A.R.5
  • 15
    • 0033841584 scopus 로고    scopus 로고
    • Deep venous thrombosis and consecutive pulmonary embolism as the first sign of an ovarian cancer: MR angiography using an intravascular contrast agent (CLARISCAN)
    • Sandstede JJW, Krause U, Pabst T, et al. Deep venous thrombosis and consecutive pulmonary embolism as the first sign of an ovarian cancer: MR angiography using an intravascular contrast agent (CLARISCAN). J Magn Reson Imaging 2000;12:497-500.
    • (2000) J Magn Reson Imaging , vol.12 , pp. 497-500
    • Sandstede, J.J.W.1    Krause, U.2    Pabst, T.3
  • 16
    • 0032867764 scopus 로고    scopus 로고
    • Venous signal suppression in 3D dynamic Gd-enhanced carotid artery imaging using the eigen-image filter
    • Kaandorp DW, Kopinga K, Wijn PF. Venous signal suppression in 3D dynamic Gd-enhanced carotid artery imaging using the eigen-image filter. Magn Reson Med 1999;42:307-313.
    • (1999) Magn Reson Med , vol.42 , pp. 307-313
    • Kaandorp, D.W.1    Kopinga, K.2    Wijn, P.F.3
  • 17
    • 0036190232 scopus 로고    scopus 로고
    • Combined time-resolved and high spatial resolution 3D MRA using an extended adaptive acquisition
    • Mazaheri Y, Carroll TJ, Du J, et al. Combined time-resolved and high spatial resolution 3D MRA using an extended adaptive acquisition. J Magn Reson Imaging 2002;15:291-301.
    • (2002) J Magn Reson Imaging , vol.15 , pp. 291-301
    • Mazaheri, Y.1    Carroll, T.J.2    Du, J.3
  • 18
    • 0036708131 scopus 로고    scopus 로고
    • Time-resolved, undersampled projection reconstruction imaging for high resolution CE-MRA of the distal runoff vessels
    • Du J, Carroll TJ, Wagner HJ, et al. Time-resolved, undersampled projection reconstruction imaging for high resolution CE-MRA of the distal runoff vessels. Magn Reson Med 2002;48:516-522.
    • (2002) Magn Reson Med , vol.48 , pp. 516-522
    • Du, J.1    Carroll, T.J.2    Wagner, H.J.3
  • 19
    • 2442476025 scopus 로고    scopus 로고
    • Soft tissue enhancement on time-resolved peripheral magnetic resonance angiography
    • Zhang HL, Kent KC, Bush HL, et al. Soft tissue enhancement on time-resolved peripheral magnetic resonance angiography. J Magn Reson Imaging 2004;19:590-597.
    • (2004) J Magn Reson Imaging , vol.19 , pp. 590-597
    • Zhang, H.L.1    Kent, K.C.2    Bush, H.L.3
  • 20
    • 0034794323 scopus 로고    scopus 로고
    • Advances in sensitivity encoding with arbitrary k-space trajectories
    • Pruessmann KP, Weiger M, Bornert P, Boesiger P. Advances in sensitivity encoding with arbitrary k-space trajectories. Magn Reson Med 2001;46:638-651.
    • (2001) Magn Reson Med , vol.46 , pp. 638-651
    • Pruessmann, K.P.1    Weiger, M.2    Bornert, P.3    Boesiger, P.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.