메뉴 건너뛰기




Volumn 26, Issue 10, 2006, Pages 1453-1464

Oxygen therapeutics: Oxygen delivery without blood

Author keywords

Blood; Blood substitutes; HBOCs; Hemoglobin; Hemoglobin based oxygen carriers; Oxygen therapeutics; Perfluorocarbons; PFCs; Red blood cells; Transfusions

Indexed keywords

2,3 DIPHOSPHOGLYCERIC ACID; ACID CITRATE DEXTROSE; BLOOD SUBSTITUTE; DIASPIRIN CROSSLINKED HEMOGLOBIN; FLUOROCARBON; FLUOSOL DA; HBOC 301; HEMOGLOBIN; HEMOSPAN; METHEMOGLOBIN REDUCTASE; NITRIC OXIDE; NITRIC OXIDE SYNTHASE; OXYGLOBIN; PERFLUOROOCTYL BROMIDE; POLITEF; POLYMERIZED HEMOGLOBIN;

EID: 33749499778     PISSN: 02770008     EISSN: None     Source Type: Journal    
DOI: 10.1592/phco.26.10.1453     Document Type: Review
Times cited : (17)

References (47)
  • 1
    • 13844309834 scopus 로고    scopus 로고
    • Anemia, allogenic blood transfusion, and immunomodulation in the critically ill
    • Raghavan M, Marik PE. Anemia, allogenic blood transfusion, and immunomodulation in the critically ill. Chest 2005;127:295-307.
    • (2005) Chest , vol.127 , pp. 295-307
    • Raghavan, M.1    Marik, P.E.2
  • 2
    • 0027417915 scopus 로고
    • Descriptive analysis of critical care units in the United States: Patient characteristics and intensive care unit utilization
    • Groeger JS, Guntupalli KK, Strosberg M, et al. Descriptive analysis of critical care units in the United States: patient characteristics and intensive care unit utilization. Crit Care Med 1993;21:279-91.
    • (1993) Crit Care Med , vol.21 , pp. 279-291
    • Groeger, J.S.1    Guntupalli, K.K.2    Strosberg, M.3
  • 3
    • 0037065340 scopus 로고    scopus 로고
    • Efficacy of recombinant human erythropoietin in critically ill patients
    • Corwin HL, Gettinger A, Pearl RG, et al. Efficacy of recombinant human erythropoietin in critically ill patients. JAMA 2002;288:2827-35.
    • (2002) JAMA , vol.288 , pp. 2827-2835
    • Corwin, H.L.1    Gettinger, A.2    Pearl, R.G.3
  • 4
    • 14944363308 scopus 로고    scopus 로고
    • Number needed to treat and cost of recombinant human erythropoietin to avoid one transfusion-related adverse event in critically ill patients
    • Shermock KM, Horn E, Lipsett PA, et al. Number needed to treat and cost of recombinant human erythropoietin to avoid one transfusion-related adverse event in critically ill patients. Crit Care Med 2005;33:497-503.
    • (2005) Crit Care Med , vol.33 , pp. 497-503
    • Shermock, K.M.1    Horn, E.2    Lipsett, P.A.3
  • 5
    • 0347517730 scopus 로고    scopus 로고
    • Surgery without blood
    • Shander A. Surgery without blood. Crit Care Med 2003;31(suppl):S708-14.
    • (2003) Crit Care Med , vol.31 , Issue.SUPPL.
    • Shander, A.1
  • 6
    • 0348147562 scopus 로고    scopus 로고
    • Blood conservation in the intensive care unit
    • Fowler RA, Berenson M. Blood conservation in the intensive care unit. Crit Care Med 2003;31(suppl):S715-20.
    • (2003) Crit Care Med , vol.31 , Issue.SUPPL.
    • Fowler, R.A.1    Berenson, M.2
  • 7
    • 0034529592 scopus 로고    scopus 로고
    • Blood substitutes: Refocusing an elusive goal
    • Winslow RM. Blood substitutes: refocusing an elusive goal. Br J Haematol 2000;111:387-96.
    • (2000) Br J Haematol , vol.111 , pp. 387-396
    • Winslow, R.M.1
  • 8
    • 23444450725 scopus 로고
    • More than a trickle of interest in blood substitutes
    • Marwick D. More than a trickle of interest in blood substitutes [editorial]. JAMA 1994;271:895.
    • (1994) JAMA , vol.271 , pp. 895
    • Marwick, D.1
  • 9
    • 2042466919 scopus 로고
    • Epidemiology of blood transfusion
    • Vamvakas EC, Taswell HF. Epidemiology of blood transfusion. Transfusion 1994;31:355-60.
    • (1994) Transfusion , vol.31 , pp. 355-360
    • Vamvakas, E.C.1    Taswell, H.F.2
  • 10
    • 0347517729 scopus 로고    scopus 로고
    • Effects of storage on efficacy of red cell transfusion: When is it not safe?
    • Ho J, Sibbaid WJ, Chin-Yee IH. Effects of storage on efficacy of red cell transfusion: when is it not safe? Crit Care Med 2003;31(suppl):S687-97.
    • (2003) Crit Care Med , vol.31 , Issue.SUPPL.
    • Ho, J.1    Sibbaid, W.J.2    Chin-Yee, I.H.3
  • 11
    • 0346256767 scopus 로고    scopus 로고
    • Red blood cell physiology in critical illness
    • Scharte M, Fink MP. Red blood cell physiology in critical illness. Crit Care Med 2003;31(suppl):S651-7.
    • (2003) Crit Care Med , vol.31 , Issue.SUPPL.
    • Scharte, M.1    Fink, M.P.2
  • 12
    • 0346887091 scopus 로고    scopus 로고
    • Risks of blood transfusion
    • Goodnough LT. Risks of blood transfusion. Crit Care Med 2003;31(suppl):S678-86.
    • (2003) Crit Care Med , vol.31 , Issue.SUPPL.
    • Goodnough, L.T.1
  • 13
    • 0035689524 scopus 로고    scopus 로고
    • Transfusion-transmitted bacterial infection in the United States, 1998 through 2000
    • Kuehnert MJ, Roth VR, Haley R, et al. Transfusion-transmitted bacterial infection in the United States, 1998 through 2000. Transfusion 2001;41:1493-9.
    • (2001) Transfusion , vol.41 , pp. 1493-1499
    • Kuehnert, M.J.1    Roth, V.R.2    Haley, R.3
  • 14
    • 0036690660 scopus 로고    scopus 로고
    • Current prevalence and incidence of infectious disease markers and estimated window-period risk in the American Red Cross blood donor population
    • Dodd RY, Notari EP, Stramer SL. Current prevalence and incidence of infectious disease markers and estimated window-period risk in the American Red Cross blood donor population. Transfusion 2002;42:975-9.
    • (2002) Transfusion , vol.42 , pp. 975-979
    • Dodd, R.Y.1    Notari, E.P.2    Stramer, S.L.3
  • 15
    • 19844370326 scopus 로고    scopus 로고
    • Transfusion practice and blood stream infections in critically ill patients
    • Shorr AF, Jackson WL, Kelly KM, Fu M, Kollef MH. Transfusion practice and blood stream infections in critically ill patients. Chest 2005;127:1722-8.
    • (2005) Chest , vol.127 , pp. 1722-1728
    • Shorr, A.F.1    Jackson, W.L.2    Kelly, K.M.3    Fu, M.4    Kollef, M.H.5
  • 16
    • 20144389119 scopus 로고    scopus 로고
    • Transfusion-related acute lung injury: Definition and review
    • Toy P, Popovsky MA, Abraham E, et al. Transfusion-related acute lung injury: definition and review. Crit Care Med 2005;33:721-6.
    • (2005) Crit Care Med , vol.33 , pp. 721-726
    • Toy, P.1    Popovsky, M.A.2    Abraham, E.3
  • 17
    • 0033787643 scopus 로고    scopus 로고
    • Transfusion errors in New York State: An analysis of 10 years' experience
    • Linden JV, Wagner K, Voytovich AE, et al. Transfusion errors in New York State: an analysis of 10 years' experience. Transfusion 2001;40:1207-13.
    • (2001) Transfusion , vol.40 , pp. 1207-1213
    • Linden, J.V.1    Wagner, K.2    Voytovich, A.E.3
  • 18
    • 0030857008 scopus 로고    scopus 로고
    • Application of pulse oximetry and the oxyhemoglobin dissociation curve in respiratory management
    • Goodfellow LM. Application of pulse oximetry and the oxyhemoglobin dissociation curve in respiratory management. Crit Care Nurs Q 1997;20(2):22-7.
    • (1997) Crit Care Nurs Q , vol.20 , Issue.2 , pp. 22-27
    • Goodfellow, L.M.1
  • 19
  • 20
    • 0038678069 scopus 로고    scopus 로고
    • Oxygen therapeutics in trauma and surgery
    • Cohn SM. Oxygen therapeutics in trauma and surgery. J Trauma 2003;54:S193-8.
    • (2003) J Trauma , vol.54
    • Cohn, S.M.1
  • 21
    • 0035007669 scopus 로고    scopus 로고
    • Oxygen therapeutics: Current concepts
    • Hill SE. Oxygen therapeutics: current concepts. Can J Anesth 2001;48:S32-40.
    • (2001) Can J Anesth , vol.48
    • Hill, S.E.1
  • 24
    • 0036839090 scopus 로고    scopus 로고
    • Hemoglobin-based oxygen carriers
    • Stowell CP. Hemoglobin-based oxygen carriers. Curr Opin Hematol 2002;9:537-43.
    • (2002) Curr Opin Hematol , vol.9 , pp. 537-543
    • Stowell, C.P.1
  • 26
    • 0030833338 scopus 로고    scopus 로고
    • Interference of o-raffinose cross-linked hemoglobin with routine Hitachi 717 assays
    • Ali AC, Campbell JA. Interference of o-raffinose cross-linked hemoglobin with routine Hitachi 717 assays. Clin Chem 1997;43:1794-6.
    • (1997) Clin Chem , vol.43 , pp. 1794-1796
    • Ali, A.C.1    Campbell, J.A.2
  • 27
    • 0034087593 scopus 로고    scopus 로고
    • A second-generation blood substitute (perfluorodichlorooctane emulsion) generates spurious elevations in platelet counts from automated hematology analyzers
    • Cuignet OY, Wood BL, Chandler WL, Spiess, BD. A second-generation blood substitute (perfluorodichlorooctane emulsion) generates spurious elevations in platelet counts from automated hematology analyzers. Anesth Analg 2000;90:517-22.
    • (2000) Anesth Analg , vol.90 , pp. 517-522
    • Cuignet, O.Y.1    Wood, B.L.2    Chandler, W.L.3    Spiess, B.D.4
  • 28
    • 0033579126 scopus 로고    scopus 로고
    • Diaspirin cross-linked hemoglobin (DCLHb) in the treatment of severe traumatic hemorrhagic shock: A randomized controlled efficacy trial
    • Sloan EP, Koenigsberg M, Gens D, et al. Diaspirin cross-linked hemoglobin (DCLHb) in the treatment of severe traumatic hemorrhagic shock: a randomized controlled efficacy trial. JAMA 1999;282:1857-64.
    • (1999) JAMA , vol.282 , pp. 1857-1864
    • Sloan, E.P.1    Koenigsberg, M.2    Gens, D.3
  • 29
    • 4344718399 scopus 로고    scopus 로고
    • Hemoglobin-based oxygen carriers
    • Greenburg AG, Kim HW. Hemoglobin-based oxygen carriers. Crit Care 2004;8(suppl 2):S61-4.
    • (2004) Crit Care , vol.8 , Issue.SUPPL. 2
    • Greenburg, A.G.1    Kim, H.W.2
  • 30
    • 0037227152 scopus 로고    scopus 로고
    • Blood substitutes: The future is now
    • Moore EE. Blood substitutes: the future is now. J Am Coll Surg 2003;196:1-17.
    • (2003) J Am Coll Surg , vol.196 , pp. 1-17
    • Moore, E.E.1
  • 32
    • 33749472537 scopus 로고    scopus 로고
    • Biopure Corporation. Hemopure: clinical development, 2005. Available from http://www.biopure.com. Accessed January 7, 2006.
    • (2005) Hemopure: Clinical Development
  • 35
    • 0031858604 scopus 로고    scopus 로고
    • The first randomized trial of human polymerized hemoglobin as a blood substitute in acute trauma and emergent surgery
    • Gould SA, Moore EE, Hoyt DB, et al. The first randomized trial of human polymerized hemoglobin as a blood substitute in acute trauma and emergent surgery. J Am Coll Surg 1998;187:113-22.
    • (1998) J Am Coll Surg , vol.187 , pp. 113-122
    • Gould, S.A.1    Moore, E.E.2    Hoyt, D.B.3
  • 36
    • 0036789874 scopus 로고    scopus 로고
    • The life-sustaining capacity of human polymerized hemoglobin when red cells might be unavailable
    • Gould SA, Moore EE, Hoyt DB, et al. The life-sustaining capacity of human polymerized hemoglobin when red cells might be unavailable. J Am Coll Surg 2002;195:445-55.
    • (2002) J Am Coll Surg , vol.195 , pp. 445-455
    • Gould, S.A.1    Moore, E.E.2    Hoyt, D.B.3
  • 37
    • 0036658336 scopus 로고    scopus 로고
    • Polymerized bovine hemoglobin solution as a replacement for allogeneic red blood cell transfusion after cardiac surgery: Results of a randomized, double-blind trial
    • Levy JH, Goodnough LT, Greilich PE, et al. Polymerized bovine hemoglobin solution as a replacement for allogeneic red blood cell transfusion after cardiac surgery: results of a randomized, double-blind trial. J Thorac Cardiovasc Surg 2002;124:35-42.
    • (2002) J Thorac Cardiovasc Surg , vol.124 , pp. 35-42
    • Levy, J.H.1    Goodnough, L.T.2    Greilich, P.E.3
  • 38
    • 4344711659 scopus 로고    scopus 로고
    • Alternatives to blood in the 21st century
    • Cohn SM. Alternatives to blood in the 21st century. Crit Care 2004;8(suppl 2):S15-17.
    • (2004) Crit Care , vol.8 , Issue.SUPPL. 2
    • Cohn, S.M.1
  • 39
    • 0035008248 scopus 로고    scopus 로고
    • Safety and efficacy of o-raffinose cross-linked human hemoglobin (Hemolink) in cardiac surgery
    • Cheng DCH. Safety and efficacy of o-raffinose cross-linked human hemoglobin (Hemolink) in cardiac surgery. Can J Anesth 2001;48:S41-8.
    • (2001) Can J Anesth , vol.48
    • Cheng, D.C.H.1
  • 42
    • 0037319963 scopus 로고    scopus 로고
    • Hb-based oxygen carriers: Are we there yet?
    • Reid TJ. Hb-based oxygen carriers: are we there yet? Transfusion 2003;43:280-7.
    • (2003) Transfusion , vol.43 , pp. 280-287
    • Reid, T.J.1
  • 43
    • 0030041349 scopus 로고    scopus 로고
    • Blood substitutes: Fluids, drugs, or miracle solutions?
    • Dietz NM, Joyner MJ, Warner MA. Blood substitutes: fluids, drugs, or miracle solutions? Anesth Analg 1996;82:390-405.
    • (1996) Anesth Analg , vol.82 , pp. 390-405
    • Dietz, N.M.1    Joyner, M.J.2    Warner, M.A.3
  • 44
    • 29544452423 scopus 로고    scopus 로고
    • Resuscitation with a hemoglobin-based oxygen carrier after traumatic brain injury
    • King DR, Cohn SM, Proctor KG. Resuscitation with a hemoglobin-based oxygen carrier after traumatic brain injury. J Trauma 2005;59:553-62.
    • (2005) J Trauma , vol.59 , pp. 553-562
    • King, D.R.1    Cohn, S.M.2    Proctor, K.G.3
  • 45
    • 0037018495 scopus 로고    scopus 로고
    • Blood substitute and erythropoietin therapy in a severely injured Jehovah's Witness
    • Cothren D, Moore EE, Offner PJ, Haenel JB, Johnson JL. Blood substitute and erythropoietin therapy in a severely injured Jehovah's Witness. N Engl J Med 2002;346:1097-8.
    • (2002) N Engl J Med , vol.346 , pp. 1097-1098
    • Cothren, D.1    Moore, E.E.2    Offner, P.J.3    Haenel, J.B.4    Johnson, J.L.5
  • 46
    • 3042637754 scopus 로고    scopus 로고
    • Large volume polymerized haemoglobin solution in a Jehovah's Witness following abruption placentae
    • Cothren CC, Moore EE, Long JS, Haenel JB, Johnson JL, Ciesla DJ. Large volume polymerized haemoglobin solution in a Jehovah's Witness following abruption placentae. Transfus Med 2004;14:241-6.
    • (2004) Transfus Med , vol.14 , pp. 241-246
    • Cothren, C.C.1    Moore, E.E.2    Long, J.S.3    Haenel, J.B.4    Johnson, J.L.5    Ciesla, D.J.6
  • 47
    • 0034212503 scopus 로고    scopus 로고
    • Transfusion of polymerized bovine hemoglobin in a patient with severe autoimmune hemolytic anemia
    • 200
    • Mullon J, Giacoppe G, Clagett C, et al. Transfusion of polymerized bovine hemoglobin in a patient with severe autoimmune hemolytic anemia. N Engl J Med 200;342:1638-43.
    • N Engl J Med , vol.342 , pp. 1638-1643
    • Mullon, J.1    Giacoppe, G.2    Clagett, C.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.