Volumn 33, Issue 10, 2006, Pages 3690-3699

Pencil beam approach for correcting the energy dependence artifact in film dosimetry for IMRT verification

Author keywords

[No Author keywords available]

Indexed keywords

DOSIMETRY; NUCLEAR INSTRUMENTATION; PHANTOMS; PHOTONS; POLYSTYRENES; RADIOTHERAPY;

EID: 33749421492     PISSN: 00942405     EISSN: None     Source Type: Journal    
DOI: 10.1118/1.2229425     Document Type: Article
Times cited : (10)

References (25)
  • 1
    • 27644471150 scopus 로고    scopus 로고
    • Weak energy dependence of EBT gafchromic film dose response in the 50 kVp-10 MVp X-ray range
    • M. J. Butson, T. Cheung, and P. K. Yu, "Weak energy dependence of EBT gafchromic film dose response in the 50 kVp-10 MVp X-ray range," Appl. Radiat. Isot. 64, 60-62 (2006).
    • (2006) Appl. Radiat. Isot. , vol.64 , pp. 60-62
    • Butson, M.J.1    Cheung, T.2    Yu, P.K.3
  • 2
    • 21344465230 scopus 로고    scopus 로고
    • Absorption spectra variations of EBT radiochromic film from radiation exposure
    • M. J. Butson, T. Cheung, and P. K. Yu, "Absorption spectra variations of EBT radiochromic film from radiation exposure," Phys. Med. Biol. 50, N135-N140 (2005).
    • (2005) Phys. Med. Biol. , vol.50
    • Butson, M.J.1    Cheung, T.2    Yu, P.K.3
  • 4
    • 21844443109 scopus 로고    scopus 로고
    • Dosimetric quality assurance for intensity-modulated radiotherapy feasibility study for a filmless approach
    • T. Wiezorek, N. Banz, M. Schwedas, M. Scheithauer, H. Salz, D. Georg, and T. G. Wendt, "Dosimetric quality assurance for intensity-modulated radiotherapy feasibility study for a filmless approach," Strahlenther. Onkol. 181, 468-474 (2005).
    • (2005) Strahlenther. Onkol. , vol.181 , pp. 468-474
    • Wiezorek, T.1    Banz, N.2    Schwedas, M.3    Scheithauer, M.4    Salz, H.5    Georg, D.6    Wendt, T.G.7
  • 6
    • 0037910445 scopus 로고    scopus 로고
    • A 2-D diode array and analysis software for verification of intensity modulated radiation therapy delivery
    • P. A. Jursinic and B. E. Nelms, "A 2-D diode array and analysis software for verification of intensity modulated radiation therapy delivery," Med. Phys. 30, 870-879 (2003).
    • (2003) Med. Phys. , vol.30 , pp. 870-879
    • Jursinic, P.A.1    Nelms, B.E.2
  • 7
    • 0035180108 scopus 로고    scopus 로고
    • An iterative EPID calibration procedure for dosimetric verification that considers the EPID scattering factor
    • J. Chang, G. S. Mageras, C. C. Ling, and W. Lutz, "An iterative EPID calibration procedure for dosimetric verification that considers the EPID scattering factor," Med. Phys. 28, 2247-2257 (2001).
    • (2001) Med. Phys. , vol.28 , pp. 2247-2257
    • Chang, J.1    Mageras, G.S.2    Ling, C.C.3    Lutz, W.4
  • 8
    • 0037458227 scopus 로고    scopus 로고
    • Dosimetric verification of x-ray fields with steep dose gradients using an electronic portal imaging device
    • S. C. Vieira, M. L. Dirkx, K. L. Pasma, and B. J. Heijmen, "Dosimetric verification of x-ray fields with steep dose gradients using an electronic portal imaging device," Phys. Med. Biol. 48, 157-166 (2003).
    • (2003) Phys. Med. Biol. , vol.48 , pp. 157-166
    • Vieira, S.C.1    Dirkx, M.L.2    Pasma, K.L.3    Heijmen, B.J.4
  • 9
    • 25644457670 scopus 로고    scopus 로고
    • Evaluation of a computed radiography system for megavoltage photon beam dosimetry
    • A. J. Olch, "Evaluation of a computed radiography system for megavoltage photon beam dosimetry," Med. Phys. 32, 2987-2999 (2005).
    • (2005) Med. Phys. , vol.32 , pp. 2987-2999
    • Olch, A.J.1
  • 10
    • 0036735811 scopus 로고    scopus 로고
    • Dosimetric performance of an enhanced dose range radiographic film for intensity-modulated radiation therapy quality assurance
    • A. J. Olch, "Dosimetric performance of an enhanced dose range radiographic film for intensity-modulated radiation therapy quality assurance," Med. Phys. 29, 2159-2168 (2002).
    • (2002) Med. Phys. , vol.29 , pp. 2159-2168
    • Olch, A.J.1
  • 11
    • 0037153141 scopus 로고    scopus 로고
    • Comparative evaluation of Kodak EDR2 and XV2 films for verification of intensity modulated radiation therapy
    • N. Dogan, L. B. Leybovich, and A. Sethi, "Comparative evaluation of Kodak EDR2 and XV2 films for verification of intensity modulated radiation therapy," Phys. Med. Biol. 47, 4121-4130 (2002).
    • (2002) Phys. Med. Biol. , vol.47 , pp. 4121-4130
    • Dogan, N.1    Leybovich, L.B.2    Sethi, A.3
  • 12
    • 11244291999 scopus 로고    scopus 로고
    • Predicting energy response of radiographic film in a 6 MV x-ray beam using Monte Carlo calculated fluence spectra and absorbed dose
    • Å. Palm, A. S. Kirov, and T. LoSasso, "Predicting energy response of radiographic film in a 6 MV x-ray beam using Monte Carlo calculated fluence spectra and absorbed dose," Med. Phys. 31, 3168-3178 (2004).
    • (2004) Med. Phys. , vol.31 , pp. 3168-3178
    • Palm, Å.1    Kirov, A.S.2    LoSasso, T.3
  • 13
    • 0032808882 scopus 로고    scopus 로고
    • Perturbation of radiotherapy beams by radiographic film: Measurements and Monte Carlo simulations
    • N. Suchowerska, P. Hoban, A. Davison, and P. Metcalfe, "Perturbation of radiotherapy beams by radiographic film: measurements and Monte Carlo simulations," Phys. Med. Biol. 44, 1755-1765 (1999).
    • (1999) Phys. Med. Biol. , vol.44 , pp. 1755-1765
    • Suchowerska, N.1    Hoban, P.2    Davison, A.3    Metcalfe, P.4
  • 14
    • 23944525811 scopus 로고    scopus 로고
    • Influence of phantom material and phantom size on radiographic film response in therapy photon beams
    • Å. Palm and T. LoSasso, "Influence of phantom material and phantom size on radiographic film response in therapy photon beams," Med. Phys. 32, 2434-2442 (2005).
    • (2005) Med. Phys. , vol.32 , pp. 2434-2442
    • Palm, Å.1    LoSasso, T.2
  • 15
    • 0019504287 scopus 로고
    • Film dosimetry of megavoltage photon beams: A practical method of isodensity-to-isodose curve conversion
    • J. F. Williamson, F. M. Khan, and S. C. Sharma, "Film dosimetry of megavoltage photon beams: A practical method of isodensity-to-isodose curve conversion," Med. Phys. 8, 94-98 (1981).
    • (1981) Med. Phys. , vol.8 , pp. 94-98
    • Williamson, J.F.1    Khan, F.M.2    Sharma, S.C.3
  • 16
    • 0030962169 scopus 로고    scopus 로고
    • A new approach to film dosimetry for high energy photon beams: Lateral scatter filtering
    • S. E. Burch, K. J. Kearfott, J. H. Trueblood, W. C. Sheils, J. I. Yeo, and C. K. C. Wang, "A new approach to film dosimetry for high energy photon beams: Lateral scatter filtering," Med. Phys. 24, 775-783 (1997).
    • (1997) Med. Phys. , vol.24 , pp. 775-783
    • Burch, S.E.1    Kearfott, K.J.2    Trueblood, J.H.3    Sheils, W.C.4    Yeo, J.I.5    Wang, C.K.C.6
  • 17
    • 0031454940 scopus 로고    scopus 로고
    • A filtration method for improving film dosimetry in photon radiation therapy
    • I. J. Yeo, C. K. Wang, and S. E. Burch, "A filtration method for improving film dosimetry in photon radiation therapy," Med. Phys. 24, 1943-1953 (1997).
    • (1997) Med. Phys. , vol.24 , pp. 1943-1953
    • Yeo, I.J.1    Wang, C.K.2    Burch, S.E.3
  • 18
    • 1642495624 scopus 로고    scopus 로고
    • Verification of IMRT fields by film dosimetry
    • M. Bucciolini, F. B. Buonamici, and M. Casati, "Verification of IMRT fields by film dosimetry," Med. Phys. 31, 161-168 (2004).
    • (2004) Med. Phys. , vol.31 , pp. 161-168
    • Bucciolini, M.1    Buonamici, F.B.2    Casati, M.3
  • 19
    • 0036127078 scopus 로고    scopus 로고
    • Film dosimetry for intensity modulated radiation therapy: Dosimetric evaluation
    • S. G. Ju, Y. C. Ahn, S. J. Huh, and I. J. Yeo, "Film dosimetry for intensity modulated radiation therapy: dosimetric evaluation," Med. Phys. 29, 351-355 (2002).
    • (2002) Med. Phys. , vol.29 , pp. 351-355
    • Ju, S.G.1    Ahn, Y.C.2    Huh, S.J.3    Yeo, I.J.4
  • 20
    • 0032965356 scopus 로고    scopus 로고
    • How much does film sensitivity increase at depth for larger field sizes?
    • J. R. Sykes, H. V. James, and P. C. Williams, "How much does film sensitivity increase at depth for larger field sizes?," Med. Phys. 26, 329-330 (1999).
    • (1999) Med. Phys. , vol.26 , pp. 329-330
    • Sykes, J.R.1    James, H.V.2    Williams, P.C.3
  • 23
    • 0037035317 scopus 로고    scopus 로고
    • Energy spectra, angular spread, fluence profiles and dose distributions of 6 and 18 MV photon beams: Results of Monte Carlo simulations for a Varian 2100EX accelerator
    • G. X. Ding, "Energy spectra, angular spread, fluence profiles and dose distributions of 6 and 18 MV photon beams: results of Monte Carlo simulations for a Varian 2100EX accelerator," Phys. Med. Biol. 47, 1025-1046 (2002).
    • (2002) Phys. Med. Biol. , vol.47 , pp. 1025-1046
    • Ding, G.X.1
  • 24
    • 0032803563 scopus 로고    scopus 로고
    • Quantitative optical densitometry with scanning-laser film digitizers
    • J. F. Dempsey, D. A. Low, A. S. Kirov, and J. F. Williamson, "Quantitative optical densitometry with scanning-laser film digitizers," Med. Phys. 26, 1721-1731 (1999).
    • (1999) Med. Phys. , vol.26 , pp. 1721-1731
    • Dempsey, J.F.1    Low, D.A.2    Kirov, A.S.3    Williamson, J.F.4