메뉴 건너뛰기




Volumn 33, Issue 10, 2006, Pages 3758-3766

Highly accelerated MRI by skipped phase encoding and edge deghosting with array coil enhancement (SPEED-ACE)

Author keywords

Array coil enhancement; Fast imaging; SPEED; SPEED ACE

Indexed keywords

ENCODING (SYMBOLS); IMAGE CODING; INVERSE PROBLEMS; SIGNAL ENCODING; SPEED;

EID: 33749407704     PISSN: 00942405     EISSN: None     Source Type: Journal    
DOI: 10.1118/1.2349700     Document Type: Article
Times cited : (13)

References (27)
  • 1
    • 36149042452 scopus 로고
    • Multi-planar image formation using NMR spin echoes
    • P. Mansfield, "Multi-planar image formation using NMR spin echoes," J. Phys. C 10, L55-L58 (1977).
    • (1977) J. Phys. C , vol.10
    • Mansfield, P.1
  • 2
    • 0022686199 scopus 로고
    • High-speed spiral-scan echo planar NMR imaging
    • C. B. Ahn, J. H. Kim, and Z. H. Cho, "High-speed spiral-scan echo planar NMR imaging," IEEE Trans. Med. Imaging MI-5, 2-7 (1986).
    • (1986) IEEE Trans. Med. Imaging , vol.MI-5 , pp. 2-7
    • Ahn, C.B.1    Kim, J.H.2    Cho, Z.H.3
  • 4
    • 0022872540 scopus 로고
    • RARE imaging: A fast imaging method for clinical MR
    • J. Hennig, A. Nauerth, and H. Friedburg, "RARE imaging: A fast imaging method for clinical MR," Magn. Reson. Med. 3, 823-833 (1986).
    • (1986) Magn. Reson. Med. , vol.3 , pp. 823-833
    • Hennig, J.1    Nauerth, A.2    Friedburg, H.3
  • 5
    • 0025783488 scopus 로고
    • GRASE MR imaging: A novel fast MRI technique
    • K. Oshio and D. A. Feinberg, "GRASE MR imaging: A novel fast MRI technique," Magn. Reson. Med. 20, 344-349 (1991).
    • (1991) Magn. Reson. Med. , vol.20 , pp. 344-349
    • Oshio, K.1    Feinberg, D.A.2
  • 6
    • 0005086204 scopus 로고    scopus 로고
    • Partial Fourier acquisition in MRI
    • edited by D. M. Grant and R. K. Harris (Wiley, New York)
    • P. M. Margosian, G. DeMeester, and H. Liu, "Partial Fourier acquisition in MRI," in Encyclopedia of Nuclear Magnetic Resonance, edited by D. M. Grant and R. K. Harris (Wiley, New York, 1996), Vol. 5, pp. 3463-3467.
    • (1996) Encyclopedia of Nuclear Magnetic Resonance , vol.5 , pp. 3463-3467
    • Margosian, P.M.1    DeMeester, G.2    Liu, H.3
  • 7
    • 0026077967 scopus 로고
    • Data extrapolation for truncation artefact removal
    • R. T. Constable and R. M. Henkelman, "Data extrapolation for truncation artefact removal," Magn. Reson. Med. 17, 108-118 (1991).
    • (1991) Magn. Reson. Med. , vol.17 , pp. 108-118
    • Constable, R.T.1    Henkelman, R.M.2
  • 8
    • 0026955747 scopus 로고
    • Dynamic image reconstruction (DIR): MR movies from motion ghosts
    • Q. S. Xiang and R. M. Henkelman, "Dynamic image reconstruction (DIR): MR movies from motion ghosts," J. Magn. Reson Imaging 2, 679-685 (1992).
    • (1992) J. Magn. Reson Imaging , vol.2 , pp. 679-685
    • Xiang, Q.S.1    Henkelman, R.M.2
  • 10
    • 0028364190 scopus 로고
    • Reduction of field of view for dynamic imaging
    • X. Hu and T. Parrish, "Reduction of field of view for dynamic imaging," Magn. Reson. Med. 31, 691-694 (1994).
    • (1994) Magn. Reson. Med. , vol.31 , pp. 691-694
    • Hu, X.1    Parrish, T.2
  • 11
    • 38249035106 scopus 로고
    • An algorithm for NMR imaging reconstruction based on multiple RF receiver coils
    • J. W. Carlson, "An algorithm for NMR imaging reconstruction based on multiple RF receiver coils," J. Magn. Reson. (1969-1992) 74, 376-380 (1987).
    • (1987) J. Magn. Reson. (1969-1992) , vol.74 , pp. 376-380
    • Carlson, J.W.1
  • 12
    • 0023870882 scopus 로고
    • Fast MRI data acquisition using multiple detectors
    • M. Hutchinson and U. Raff, "Fast MRI data acquisition using multiple detectors," Magn. Reson. Med. 6, 87-91 (1988).
    • (1988) Magn. Reson. Med. , vol.6 , pp. 87-91
    • Hutchinson, M.1    Raff, U.2
  • 13
    • 0025777470 scopus 로고
    • A decoupled coil detector array for fast image acquisition in magnetic resonance imaging
    • D. Kwiat, S. Einav, and G. Navon, "A decoupled coil detector array for fast image acquisition in magnetic resonance imaging," Med. Phys. 18, 251-265 (1991).
    • (1991) Med. Phys. , vol.18 , pp. 251-265
    • Kwiat, D.1    Einav, S.2    Navon, G.3
  • 14
    • 0027319233 scopus 로고
    • Fast imaging using subencoding data sets from multiple detectors
    • J. B. Ra and C. Y. Rim, "Fast imaging using subencoding data sets from multiple detectors," Magn. Reson. Med. 30, 142-145 (1993).
    • (1993) Magn. Reson. Med. , vol.30 , pp. 142-145
    • Ra, J.B.1    Rim, C.Y.2
  • 15
    • 0030982409 scopus 로고    scopus 로고
    • Simultaneous acquisition of spatial harmonics (SMASH): Ultra-fast imaging with radiofrequency coil arrays
    • D. K. Sodickson and W. J. Manning, "Simultaneous acquisition of spatial harmonics (SMASH): Ultra-fast imaging with radiofrequency coil arrays," Magn. Reson. Med. 38, 591-603 (1997).
    • (1997) Magn. Reson. Med. , vol.38 , pp. 591-603
    • Sodickson, D.K.1    Manning, W.J.2
  • 20
    • 18244404840 scopus 로고    scopus 로고
    • Accelerating MRI by skipped phase encoding and edge deghosting (SPEED)
    • Q. S. Xiang, "Accelerating MRI by skipped phase encoding and edge deghosting (SPEED)," Magn. Reson. Med. 53, 1112-1117 (2005).
    • (2005) Magn. Reson. Med. , vol.53 , pp. 1112-1117
    • Xiang, Q.S.1
  • 21
    • 0027468047 scopus 로고
    • K-space description for the MR imaging of dynamic objects
    • Q. S. Xiang and R. M. Henkelman, "K-space description for the MR imaging of dynamic objects," Magn. Reson. Med. 29, 422-428 (1993).
    • (1993) Magn. Reson. Med. , vol.29 , pp. 422-428
    • Xiang, Q.S.1    Henkelman, R.M.2
  • 22
    • 0026247741 scopus 로고
    • Motion artifact reduction with three-point ghost phase cancellation
    • Q. S. Xiang and R. M. Henkelman, "Motion artifact reduction with three-point ghost phase cancellation," J. Magn. Reson Imaging 1, 633-642 (1991).
    • (1991) J. Magn. Reson Imaging , vol.1 , pp. 633-642
    • Xiang, Q.S.1    Henkelman, R.M.2
  • 24
    • 3543101032 scopus 로고    scopus 로고
    • Electrodynamics and ultimate SNR in parallel MR imaging
    • F. Wiesinger, P. Boesiger, and K. P. Pruessmann, "Electrodynamics and ultimate SNR in parallel MR imaging," Magn. Reson. Med. 52, 376-390 (2004).
    • (2004) Magn. Reson. Med. , vol.52 , pp. 376-390
    • Wiesinger, F.1    Boesiger, P.2    Pruessmann, K.P.3
  • 25
    • 0242385481 scopus 로고    scopus 로고
    • Ultimate intrinsic signal-to-noise ratio for parallel MRI: Electromagnetic field considerations
    • M. A. Ohliger, A. K. Grant, and D. K. Sodickson, "Ultimate intrinsic signal-to-noise ratio for parallel MRI: Electromagnetic field considerations," Magn. Reson. Med. 50, 1018-1030 (2003).
    • (2003) Magn. Reson. Med. , vol.50 , pp. 1018-1030
    • Ohliger, M.A.1    Grant, A.K.2    Sodickson, D.K.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.