메뉴 건너뛰기




Volumn 69, Issue 8, 2006, Pages 825-834

The Nikon C1si combines high spectral resolution, high sensitivity, and high acquisition speed

Author keywords

Calibration; Confocal microscopy; Fluorescence; Nikon; Spectral imaging; Spectral unmixing

Indexed keywords

FLUORESCENT DYE;

EID: 33749126078     PISSN: 15524922     EISSN: 15524930     Source Type: Journal    
DOI: 10.1002/cyto.a.20305     Document Type: Article
Times cited : (24)

References (11)
  • 1
    • 29244443049 scopus 로고
    • Scanning laser microscope for biological investigations
    • Davidovits P, Egger MD. Scanning laser microscope for biological investigations. Appl Opt 1971;10:1615-1619.
    • (1971) Appl Opt , vol.10 , pp. 1615-1619
    • Davidovits, P.1    Egger, M.D.2
  • 4
    • 33749135782 scopus 로고
    • New spectrally resolved scanning laser microscope
    • Bowron JW, Damaskinos S, Dixon A. New spectrally resolved scanning laser microscope. Proc SPIE 1992;1556:124-135.
    • (1992) Proc SPIE , vol.1556 , pp. 124-135
    • Bowron, J.W.1    Damaskinos, S.2    Dixon, A.3
  • 5
    • 0035205294 scopus 로고    scopus 로고
    • Multi-spectral imaging and linear unmixing add a whole new dimension to laser scanning fluorescence microscopy
    • Dickinson ME, Bearman G, Tille S, Lansford R, Fraser SE. Multi-spectral imaging and linear unmixing add a whole new dimension to laser scanning fluorescence microscopy. Biotechniques 2001;31:1272-1278.
    • (2001) Biotechniques , vol.31 , pp. 1272-1278
    • Dickinson, M.E.1    Bearman, G.2    Tille, S.3    Lansford, R.4    Fraser, S.E.5
  • 7
    • 0038199783 scopus 로고    scopus 로고
    • Spectral imaging and its applications in live cell microscopy
    • Zimmerman T, Reitdorf J, Pepperkok R. Spectral imaging and its applications in live cell microscopy. FEBS Lett 2003;546:87-92.
    • (2003) FEBS Lett , vol.546 , pp. 87-92
    • Zimmerman, T.1    Reitdorf, J.2    Pepperkok, R.3
  • 8
    • 0037032454 scopus 로고    scopus 로고
    • Spectral imaging and linear unmixing enables improved FRET efficiency with a novel GFP2-YFP FRET pair
    • Zimmerman T, Reitdorf J, Girod A, Georget V, Pepperkok R. Spectral imaging and linear unmixing enables improved FRET efficiency with a novel GFP2-YFP FRET pair. FEBS Lett 2002;531:245-249.
    • (2002) FEBS Lett , vol.531 , pp. 245-249
    • Zimmerman, T.1    Reitdorf, J.2    Girod, A.3    Georget, V.4    Pepperkok, R.5
  • 9
    • 2142751612 scopus 로고    scopus 로고
    • Evaluation of spectral imaging for plant cell analysis
    • Berg RH. Evaluation of spectral imaging for plant cell analysis. J Microsc 2004;214 (Part 2):174-181.
    • (2004) J Microsc , vol.214 , Issue.2 PART , pp. 174-181
    • Berg, R.H.1
  • 10
    • 8144220677 scopus 로고    scopus 로고
    • Calibration and validation of confocal spectral imaging systems
    • Lerner JM, Zucker RM. Calibration and validation of confocal spectral imaging systems. Cytometry A 2004;62:8-34.
    • (2004) Cytometry A , vol.62 , pp. 8-34
    • Lerner, J.M.1    Zucker, R.M.2
  • 11
    • 29344456949 scopus 로고    scopus 로고
    • Wavelength and alignment tests for confocal spectral imaging systems
    • Zucker RM, Lerner JM. Wavelength and alignment tests for confocal spectral imaging systems. Microsc Res Tech 2005;68:307-319.
    • (2005) Microsc Res Tech , vol.68 , pp. 307-319
    • Zucker, R.M.1    Lerner, J.M.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.