2
-
-
0032079163
-
Dynamic response of a hot-wire anemometer: II. A flush-mounted hot-wire and hot-film probes for wall shear stress measurements
-
Chew Y T, Khoo B C, Lim C P and Teo C J 1998 Dynamic response of a hot-wire anemometer: II. A flush-mounted hot-wire and hot-film probes for wall shear stress measurements Meas. Sci. Technol. 9 764-78
-
(1998)
Meas. Sci. Technol.
, vol.9
, Issue.5
, pp. 764-778
-
-
Chew, Y.T.1
Khoo, B.C.2
Lim, C.P.3
Teo, C.J.4
-
3
-
-
0001075869
-
Heat transfer by forced convection from a cylinder to water in cross flow
-
Fand R M 1965 Heat transfer by forced convection from a cylinder to water in cross flow Int. J. Heat Mass Transfer 8 995
-
(1965)
Int. J. Heat Mass Transfer
, vol.8
, Issue.7
, pp. 995
-
-
Fand, R.M.1
-
4
-
-
0017518913
-
Frequency response and electronic testing for constant-temperature hot-wire anemometers
-
Freymuth P 1977a Frequency response and electronic testing for constant-temperature hot-wire anemometers J. Phys. E: Sci. Instrum 10 705-10
-
(1977)
J. Phys. E: Sci. Instrum
, vol.10
, Issue.7
, pp. 705-710
-
-
Freymuth, P.1
-
5
-
-
0018316810
-
Engineering estimation of heat conduction loss in constant temperature thermal sensors
-
Freymuth P 1979 Engineering estimation of heat conduction loss in constant temperature thermal sensors TSI Q. V (3) 3-9
-
(1979)
TSI Q.
, vol.5
, Issue.3
, pp. 3-9
-
-
Freymuth, P.1
-
6
-
-
0017434311
-
Electronic testing of frequency response for anemometers
-
Freymuth P and Fingerson L M 1977 Electronic testing of frequency response for anemometers TSI Q. III (4) 5-12
-
(1977)
TSI Q.
, vol.3
, Issue.4
, pp. 5-12
-
-
Freymuth, P.1
Fingerson, L.M.2
-
8
-
-
0032077752
-
Dynamic response of a hot-wire anemometer: I. A marginally elevated hot-wire probe for near-wall velocity measurements
-
Khoo B C, Chew Y T, Lim C P and Teo C J 1998 Dynamic response of a hot-wire anemometer: I. A marginally elevated hot-wire probe for near-wall velocity measurements Meas. Sci. Technol. 9 751-63
-
(1998)
Meas. Sci. Technol.
, vol.9
, Issue.5
, pp. 751-763
-
-
Khoo, B.C.1
Chew, Y.T.2
Lim, C.P.3
Teo, C.J.4
-
9
-
-
0033104530
-
The dynamic response of a hot-wire anemometer: III. Voltage-perturbation versus velocity-perturbation testing for near-wall hot-wire/film probes
-
Khoo B C, Chew Y T, Teo C J and Lim C P 1999 The dynamic response of a hot-wire anemometer: III. Voltage-perturbation versus velocity-perturbation testing for near-wall hot-wire/film probes Meas. Sci. Technol. 10 152-69
-
(1999)
Meas. Sci. Technol.
, vol.10
, Issue.3
, pp. 152-169
-
-
Khoo, B.C.1
Chew, Y.T.2
Teo, C.J.3
Lim, C.P.4
-
10
-
-
33645609121
-
Dynamic response of constant temperature hot-wire system in turbulent velocity measurements
-
Li J D 2004a Dynamic response of constant temperature hot-wire system in turbulent velocity measurements Meas. Sci. Technol. 15 1835-47
-
(2004)
Meas. Sci. Technol.
, vol.15
, Issue.9
, pp. 1835-1847
-
-
Li, J.D.1
-
11
-
-
33749008095
-
The cut-off frequency of constant temperature hot-wire systems in turbulent velocity measurements
-
Li J D 2004b The cut-off frequency of constant temperature hot-wire systems in turbulent velocity measurements 15th Australasian Fluid Mechanics Conf. (Sydney University, 13-17 Dec.)
-
(2004)
15th Australasian Fluid Mechanics Conf.
-
-
Li, J.D.1
-
12
-
-
24144463693
-
The effect of electronic components on the cut-off frequency of the hot-wire system
-
Li J D 2005 The effect of electronic components on the cut-off frequency of the hot-wire system Meas. Sci. Technol. 16 766-74
-
(2005)
Meas. Sci. Technol.
, vol.16
, Issue.3
, pp. 766-774
-
-
Li, J.D.1
-
13
-
-
0037351708
-
Transient thermal response of a hot-wire anemometer
-
Morris S C and Foss J F 2003 Transient thermal response of a hot-wire anemometer Meas. Sci. Technol. 14 251-9
-
(2003)
Meas. Sci. Technol.
, vol.14
, Issue.3
, pp. 251-259
-
-
Morris, S.C.1
Foss, J.F.2
-
15
-
-
0014997069
-
Static dynamic calibrations of constant-temperature hot-wire systems
-
Perry A E and Morrison G L 1977 Static dynamic calibrations of constant-temperature hot-wire systems J. Fluid Mech. 47 765-77
-
(1977)
J. Fluid Mech.
, vol.47
, Issue.4
, pp. 765-777
-
-
Perry, A.E.1
Morrison, G.L.2
-
16
-
-
0035101885
-
The dynamic response of a hot-wire anemometer: IV. Sine-wave voltage perturbation testing for near-wall hot-wire/film probes and the presence of low-high frequency response characteristics
-
Teo C J, Khoo B C and Chew Y T 2001 The dynamic response of a hot-wire anemometer: IV. Sine-wave voltage perturbation testing for near-wall hot-wire/film probes and the presence of low-high frequency response characteristics Meas. Sci. Technol. 12 37-51
-
(2001)
Meas. Sci. Technol.
, vol.12
, Issue.1
, pp. 37-51
-
-
Teo, C.J.1
Khoo, B.C.2
Chew, Y.T.3
|