메뉴 건너뛰기




Volumn 22, Issue 7, 2006, Pages 665-670

Ultrasound and partial coherence interferometry with measurement of central corneal thickness

Author keywords

[No Author keywords available]

Indexed keywords

ADULT; ARTICLE; CORNEA DISEASE; CORNEA THICKNESS; DEVICE; DIAGNOSTIC ACCURACY; FEMALE; HUMAN; INTERFEROMETRY; INTRAOCULAR PRESSURE; MAJOR CLINICAL STUDY; MALE; MEASUREMENT; OBSERVER VARIATION; PARTIAL COHERENCE INTERFEROMETRY; PRIORITY JOURNAL; REFRACTION ERROR; REFRACTION INDEX; REPRODUCIBILITY; ULTRASOUND;

EID: 33748604288     PISSN: 1081597X     EISSN: None     Source Type: Journal    
DOI: 10.3928/1081-597x-20060901-07     Document Type: Article
Times cited : (10)

References (32)
  • 1
    • 0036235038 scopus 로고    scopus 로고
    • Effect of corneal thickness on intraocular pressure measurements with the pneumotonometer, Goldmann applanation tonometer, and Tono-Pen
    • Bhan A, Browning AC, Shah S, Hamilton R, Dave D, Dua HS, Effect of corneal thickness on intraocular pressure measurements with the pneumotonometer, Goldmann applanation tonometer, and Tono-Pen. Invest Ophthalmol Vis Sci. 2002;43:1389-1392.
    • (2002) Invest Ophthalmol Vis Sci , vol.43 , pp. 1389-1392
    • Bhan, A.1    Browning, A.C.2    Shah, S.3    Hamilton, R.4    Dave, D.5    Dua, H.S.6
  • 2
    • 7044264342 scopus 로고    scopus 로고
    • The effect of corneal thickness on intraocular pressure measurement in patients with corneal pathology
    • Browning AC, Bhan A, Rotchford AP, Shah S, Dua HS. The effect of corneal thickness on intraocular pressure measurement in patients with corneal pathology. Br J Ophthalmol. 2004;88:1395-1399.
    • (2004) Br J Ophthalmol , vol.88 , pp. 1395-1399
    • Browning, A.C.1    Bhan, A.2    Rotchford, A.P.3    Shah, S.4    Dua, H.S.5
  • 3
    • 0034915938 scopus 로고    scopus 로고
    • Central corneal thickness measurements in patients with normal tension glaucoma, primary open angle glaucoma, pseudoexfoliation glaucoma, or ocular hypertension
    • Ventura AC, Bohnke M, Mojon DS. Central corneal thickness measurements in patients with normal tension glaucoma, primary open angle glaucoma, pseudoexfoliation glaucoma, or ocular hypertension. Br J Ophthalmol. 2001;85:792-795.
    • (2001) Br J Ophthalmol , vol.85 , pp. 792-795
    • Ventura, A.C.1    Bohnke, M.2    Mojon, D.S.3
  • 4
    • 0033642305 scopus 로고    scopus 로고
    • The correlation between IOP measurement, central corneal thickness and corneal curvature
    • Burvenich H, Sallet G, De Clercq J. The correlation between IOP measurement, central corneal thickness and corneal curvature. Bull Soc Belge Ophtalmol. 2000;276:23-26.
    • (2000) Bull Soc Belge Ophtalmol , vol.276 , pp. 23-26
    • Burvenich, H.1    Sallet, G.2    De Clercq, J.3
  • 5
    • 0034603359 scopus 로고    scopus 로고
    • Human corneal thickness and its impact on intraocular pressure measures: A review and meta-analysis approach
    • Doughty MJ, Zaman ML. Human corneal thickness and its impact on intraocular pressure measures: a review and meta-analysis approach. Surv Ophthalmol. 2000;44:367-408.
    • (2000) Surv Ophthalmol , vol.44 , pp. 367-408
    • Doughty, M.J.1    Zaman, M.L.2
  • 6
    • 11144314293 scopus 로고    scopus 로고
    • Continuous monitoring of corneal thickness changes during LASIK with online optical coherence pachymetry
    • Wirbelauer C, Pham DT. Continuous monitoring of corneal thickness changes during LASIK with online optical coherence pachymetry. J Cataract Refract Surg. 2004;30:2559-2568.
    • (2004) J Cataract Refract Surg , vol.30 , pp. 2559-2568
    • Wirbelauer, C.1    Pham, D.T.2
  • 8
    • 0347763535 scopus 로고    scopus 로고
    • Comparison of four corneal pachymetry techniques in corneal refractive surgery
    • Javaloy J, Vidal MT, Villada JR, Artola A, Alio JL. Comparison of four corneal pachymetry techniques in corneal refractive surgery. J Refract Surg. 2004;20:29-34.
    • (2004) J Refract Surg , vol.20 , pp. 29-34
    • Javaloy, J.1    Vidal, M.T.2    Villada, J.R.3    Artola, A.4    Alio, J.L.5
  • 10
    • 2342474638 scopus 로고    scopus 로고
    • Comparison of Orbscan and ultrasound pachymetry in the measurement of central corneal thickness
    • Radford SW, Lim R, Salmon JF. Comparison of Orbscan and ultrasound pachymetry in the measurement of central corneal thickness. Eye. 2004;18:434-436.
    • (2004) Eye , vol.18 , pp. 434-436
    • Radford, S.W.1    Lim, R.2    Salmon, J.F.3
  • 11
    • 2942623857 scopus 로고    scopus 로고
    • Corneal thickness measurement by confocal microscopy, ultrasound, and scanning slit methods
    • McLaren JW, Nau CB, Erie JC, Bourne WM. Corneal thickness measurement by confocal microscopy, ultrasound, and scanning slit methods. Am J Ophthalmol. 2004;137:1011-1020.
    • (2004) Am J Ophthalmol , vol.137 , pp. 1011-1020
    • McLaren, J.W.1    Nau, C.B.2    Erie, J.C.3    Bourne, W.M.4
  • 12
    • 1842609805 scopus 로고    scopus 로고
    • Comparison of corneal thickness measurements using Orbscan II, non-contact specular microscopy, and ultrasonic pachymetry in eyes after laser in situ keratomileusis
    • Kawana K, Tokunaga T, Miyata K, Okamoto F, Kiuchi T, Oshika T. Comparison of corneal thickness measurements using Orbscan II, non-contact specular microscopy, and ultrasonic pachymetry in eyes after laser in situ keratomileusis. Br J Ophthalmol. 2004;88:466-468.
    • (2004) Br J Ophthalmol , vol.88 , pp. 466-468
    • Kawana, K.1    Tokunaga, T.2    Miyata, K.3    Okamoto, F.4    Kiuchi, T.5    Oshika, T.6
  • 13
    • 3843067783 scopus 로고    scopus 로고
    • Comparison of optical coherence reflectometry and ultrasound central corneal pachymetry
    • Gillis A, Zeyen T. Comparison of optical coherence reflectometry and ultrasound central corneal pachymetry. Bull Soc Belge Ophtalmol. 2004;292:71-75.
    • (2004) Bull Soc Belge Ophtalmol , vol.292 , pp. 71-75
    • Gillis, A.1    Zeyen, T.2
  • 14
    • 0038650775 scopus 로고    scopus 로고
    • Comparison of central corneal thickness measurements by specular microscopy, ultrasound pachymetry, and ultrasound biomicroscopy
    • Tam ES, Rootman DS. Comparison of central corneal thickness measurements by specular microscopy, ultrasound pachymetry, and ultrasound biomicroscopy. J Cataract Refract Surg. 2003;29:1179-1184.
    • (2003) J Cataract Refract Surg , vol.29 , pp. 1179-1184
    • Tam, E.S.1    Rootman, D.S.2
  • 16
    • 0026051506 scopus 로고
    • Micron-resolution ranging of cornea anterior chamber by optical reflectometry
    • Huang D, Wang J, Lin CP, Puliafito CA, Fujimoto JG. Micron-resolution ranging of cornea anterior chamber by optical reflectometry. Lasers Surg Med. 1991;11:419-425.
    • (1991) Lasers Surg Med , vol.11 , pp. 419-425
    • Huang, D.1    Wang, J.2    Lin, C.P.3    Puliafito, C.A.4    Fujimoto, J.G.5
  • 20
    • 0028791287 scopus 로고
    • Comparing methods of measurement: Why plotting difference against standard method is misleading
    • Bland JM, Altman DG. Comparing methods of measurement: why plotting difference against standard method is misleading. Lancet. 1995;346:1085-1087.
    • (1995) Lancet , vol.346 , pp. 1085-1087
    • Bland, J.M.1    Altman, D.G.2
  • 21
    • 84908219488 scopus 로고
    • Statistical methods for assessing agreement between two methods of clinical measurement
    • Bland JM, Altman DG. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet. 1986;1:307-310.
    • (1986) Lancet , vol.1 , pp. 307-310
    • Bland, J.M.1    Altman, D.G.2
  • 22
    • 0034536577 scopus 로고    scopus 로고
    • Corneal optical coherence tomography before and immediately after excimer laser photorefractive keratectomy
    • Wirbelauer C, Scholz C, Hoerauf H, Engelhardt R, Birngruber R, Laqua H. Corneal optical coherence tomography before and immediately after excimer laser photorefractive keratectomy. Am J Ophthalmol. 2000;130:693-699.
    • (2000) Am J Ophthalmol , vol.130 , pp. 693-699
    • Wirbelauer, C.1    Scholz, C.2    Hoerauf, H.3    Engelhardt, R.4    Birngruber, R.5    Laqua, H.6
  • 23
    • 0036862048 scopus 로고    scopus 로고
    • Correlational study of central corneal thickness measurements on Hong Kong Chinese using optical coherence tomography, Orbscan and ultrasound pachymetry
    • Wong AC, Wong CC, Yuen NS, Hui SP. Correlational study of central corneal thickness measurements on Hong Kong Chinese using optical coherence tomography, Orbscan and ultrasound pachymetry. Eye. 2002;16:715-721.
    • (2002) Eye , vol.16 , pp. 715-721
    • Wong, A.C.1    Wong, C.C.2    Yuen, N.S.3    Hui, S.P.4
  • 24
    • 0035171269 scopus 로고    scopus 로고
    • Central corneal thickness measurement with a retinal optical coherence tomography device versus standard ultrasonic pachymetry
    • Bechmann M, Thiel MJ, Neubauer AS, Ullrich S, Ludwig K, Kenyon KR, Ulbig MW. Central corneal thickness measurement with a retinal optical coherence tomography device versus standard ultrasonic pachymetry. Cornea. 2001;20:50-54.
    • (2001) Cornea , vol.20 , pp. 50-54
    • Bechmann, M.1    Thiel, M.J.2    Neubauer, A.S.3    Ullrich, S.4    Ludwig, K.5    Kenyon, K.R.6    Ulbig, M.W.7
  • 25
    • 0031814051 scopus 로고    scopus 로고
    • Measuring corneal thickness in photo-keratectomy with a reflectometry incorporated into the laser beam of the excimer laser
    • Bohnke M, Walti R, Lindgren F, Gianotti R, Bonvin P, Salathe RP. Measuring corneal thickness in photo-keratectomy with a reflectometry incorporated into the laser beam of the excimer laser [German]. Klin Monatsbl Augenheilkd. 1998;212:367-371.
    • (1998) Klin Monatsbl Augenheilkd , vol.212 , pp. 367-371
    • Bohnke, M.1    Walti, R.2    Lindgren, F.3    Gianotti, R.4    Bonvin, P.5    Salathe, R.P.6
  • 26
    • 0036234322 scopus 로고    scopus 로고
    • Optical low coherence reflectometry for noncontact measurements of flap thickness during laser in situ keratomileusis
    • Genth U, Mrochen M, Walti R, Salaheldine MM, Seiler T. Optical low coherence reflectometry for noncontact measurements of flap thickness during laser in situ keratomileusis. Ophthalmology. 2002;109:973-978.
    • (2002) Ophthalmology , vol.109 , pp. 973-978
    • Genth, U.1    Mrochen, M.2    Walti, R.3    Salaheldine, M.M.4    Seiler, T.5
  • 30
    • 0347764650 scopus 로고    scopus 로고
    • Group index of the human cornea at 1.3-micron wavelength obtained in vitro by optical coherence domain reflectometry
    • Lin RC, Shure MA, Rollins AM, Izatt JA, Huang D. Group index of the human cornea at 1.3-micron wavelength obtained in vitro by optical coherence domain reflectometry. Opt Lett. 2004;29:83-85.
    • (2004) Opt Lett , vol.29 , pp. 83-85
    • Lin, R.C.1    Shure, M.A.2    Rollins, A.M.3    Izatt, J.A.4    Huang, D.5
  • 31
    • 0042201932 scopus 로고    scopus 로고
    • Corneal thickness measurements: Scanning-slit corneal topography and noncontact specular microscopy versus ultrasonic pachymetry
    • Suzuki S, Oshika T, Oki K, Sakabe I, Iwase A, Amano S, Araie M. Corneal thickness measurements: scanning-slit corneal topography and noncontact specular microscopy versus ultrasonic pachymetry. J Cataract Refract Surg. 2003;29:1313-1318.
    • (2003) J Cataract Refract Surg , vol.29 , pp. 1313-1318
    • Suzuki, S.1    Oshika, T.2    Oki, K.3    Sakabe, I.4    Iwase, A.5    Amano, S.6    Araie, M.7
  • 32
    • 0036931699 scopus 로고    scopus 로고
    • Comparison of ultrasound pachymetry and partial coherence interferometry in the measurement of central corneal thickness
    • Rainer G, Petternel V, Findl O, Schmetterer L, Skorpik C, Luksch A, Drexler W. Comparison of ultrasound pachymetry and partial coherence interferometry in the measurement of central corneal thickness. J Cataract Refract Surg. 2002;28:2142-2145.
    • (2002) J Cataract Refract Surg , vol.28 , pp. 2142-2145
    • Rainer, G.1    Petternel, V.2    Findl, O.3    Schmetterer, L.4    Skorpik, C.5    Luksch, A.6    Drexler, W.7


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.