메뉴 건너뛰기




Volumn 212, Issue 5, 1998, Pages 367-371

Measurement of corneal thickness by low coherence reflectometry;Messung der Hornhautdicke bei der Photo-Keratektomie mit einem in den Strahlengang des Excimer-Lasers integrierten Reflektometer

Author keywords

Corneal pachymetry; Corneal photoablation; Excimer laser; Optical low coherence reflectometry; Photorefractive keratectomy

Indexed keywords

ARTICLE; CORNEA THICKNESS; EXCIMER LASER; KERATECTOMY; KERATOMETRY; LASER SURGERY; REFLECTOMETRY; VISUAL SYSTEM;

EID: 0031814051     PISSN: 00232165     EISSN: None     Source Type: Journal    
DOI: 10.1055/s-2008-1034908     Document Type: Article
Times cited : (7)

References (26)
  • 1
    • 0018377528 scopus 로고
    • A comparison of three methods for the measurement of corneal thickness
    • Azen SP, Burg KA, Smith RE, Maguen E. A comparison of three methods for the measurement of corneal thickness. Invest Ophthalmol Vis Sci 1979; 18:535-538
    • (1979) Invest Ophthalmol Vis Sci , vol.18 , pp. 535-538
    • Azen, S.P.1    Burg, K.A.2    Smith, R.E.3    Maguen, E.4
  • 2
    • 0031164821 scopus 로고    scopus 로고
    • Rapid and scalable scans at 21 m/s in optical low-coherence reflectometry
    • Ballif J, Gianotti R, Chavunne Ph, Wälti R, Salathé RP. Rapid and scalable scans at 21 m/s in optical low-coherence reflectometry. Opt Lett 1997; 22:757-759
    • (1997) Opt Lett , vol.22 , pp. 757-759
    • Ballif, J.1    Gianotti, R.2    Chavunne, Ph.3    Wälti, R.4    Salathé, R.P.5
  • 3
    • 0030274621 scopus 로고    scopus 로고
    • High speed, high precision measurement of excimer laser keratectomies with a new optical pachymeter
    • Böhnke M, Chavanne Ph, Gianotti R, Salnthé RP. High speed, high precision measurement of excimer laser keratectomies with a new optical pachymeter. Ger J Ophthalmol 1997; 5:338-342
    • (1997) Ger J Ophthalmol , vol.5 , pp. 338-342
    • Böhnke, M.1    Chavanne, Ph.2    Gianotti, R.3    Salnthé, R.P.4
  • 8
    • 0026588378 scopus 로고
    • Comparison of central corneal thickness measurements between optical and ultrasound pachometers
    • Giasson C, Forthomme D. Comparison of central corneal thickness measurements between optical and ultrasound pachometers. Optom Vis Sci 1992; 69:236-241
    • (1992) Optom Vis Sci , vol.69 , pp. 236-241
    • Giasson, C.1    Forthomme, D.2
  • 12
    • 0026051506 scopus 로고
    • Micron-resolution ranging of cornea and anterior chamber by optical reflectometry
    • Huang D, Wang J, Lin CP, Puliafito CA, Fujimoto JG. Micron-resolution ranging of cornea and anterior chamber by optical reflectometry. Lasers Surg Mod 1991; 11:419-425
    • (1991) Lasers Surg Mod , vol.11 , pp. 419-425
    • Huang, D.1    Wang, J.2    Lin, C.P.3    Puliafito, C.A.4    Fujimoto, J.G.5
  • 15
    • 0026999275 scopus 로고
    • Lamellar excimer laser keratoplasty: Reproducible photoablation of corneal tissue
    • Kubota T, Seitz B, Tetsumoto K, Naumann GOH. Lamellar excimer laser keratoplasty: Reproducible photoablation of corneal tissue. Doc Ophthalmol 1992; 82:193-200
    • (1992) Doc Ophthalmol , vol.82 , pp. 193-200
    • Kubota, T.1    Seitz, B.2    Tetsumoto, K.3    Naumann, G.O.H.4
  • 16
    • 0014374676 scopus 로고
    • Measurement of corneal thickness with the Haag-Steit pachometer
    • MishimaS, Hedbys BO. Measurement of corneal thickness with the Haag-Steit pachometer. Arch Ophthalmol, 1968; 80:710-713
    • (1968) Arch Ophthalmol , vol.80 , pp. 710-713
    • Mishima, S.1    Hedbys, B.O.2
  • 17
    • 0030985492 scopus 로고    scopus 로고
    • Quantification of stromal thinning, epithelial thickness, and corneal haze after photorefractive keratectomy using in vivo confocal microscopy
    • Møller-Pedersen T, Vogel M, Li HF, Petroll WM, Cavanagh HD, Jester JV. Quantification of stromal thinning, epithelial thickness, and corneal haze after photorefractive keratectomy using in vivo confocal microscopy Ophthalmology 1997; 104:360-368
    • (1997) Ophthalmology , vol.104 , pp. 360-368
    • Møller-Pedersen, T.1    Vogel, M.2    Li, H.F.3    Petroll, W.M.4    Cavanagh, H.D.5    Jester, J.V.6
  • 18
    • 0019215480 scopus 로고
    • On the optical measurement of corneal thickness. I. Optical principle and sources of error
    • Olsen T, Nielsen CB, Ehlers N. On the optical measurement of corneal thickness. I. Optical principle and sources of error. Acta Ophthalmol (Copenh) 1980; 58:760-766
    • (1980) Acta Ophthalmol (Copenh) , vol.58 , pp. 760-766
    • Olsen, T.1    Nielsen, C.B.2    Ehlers, N.3
  • 19
    • 0021687438 scopus 로고
    • The thickness of the human cornea as determined by a specular method
    • Olsen T, Ehlers N. The thickness of the human cornea as determined by a specular method. Acta Ophthalmologica 1984; 62:859-871
    • (1984) Acta Ophthalmologica , vol.62 , pp. 859-871
    • Olsen, T.1    Ehlers, N.2
  • 20
    • 0028084929 scopus 로고
    • Epithelial and corneal thickness measurements by high-frequency ultrasound digital signal processing
    • Reinstein DZ, BChir, Silverman RH, Rondeau MJ, Coleman DJ. Epithelial and corneal thickness measurements by high-frequency ultrasound digital signal processing. Ophthalmology 1994; 101:140-146
    • (1994) Ophthalmology , vol.101 , pp. 140-146
    • Reinstein, D.Z.1    Chir, B.2    Silverman, R.H.3    Rondeau, M.J.4    Coleman, D.J.5
  • 22
    • 0028361061 scopus 로고
    • Measurement of corneal thickness by ultrasound after photorefractive keratectomy in high myopia
    • Sabetii I., Spadea I., Furcese N, Balestrazzi E. Measurement of corneal thickness by ultrasound after photorefractive keratectomy in high myopia. J Refract Corneal Surg 1994; 10:211-216
    • (1994) J Refract Corneal Surg , vol.10 , pp. 211-216
    • Sabetii, I.1    Spadea, I.2    Furcese, N.3    Balestrazzi, E.4
  • 23
    • 0021035876 scopus 로고
    • Evaluation and comparison of sources of variability in the measurement of corneal thickness with ultrasonic and optical pachometters
    • Salz JJ, Azen SP, Berstein J, Caroline P, Vitlasenor RA, Schanzlin DJ. Evaluation and comparison of sources of variability in the measurement of corneal thickness with ultrasonic and optical pachometters. Ophthalmic Surg 1983; 14:750-754
    • (1983) Ophthalmic Surg , vol.14 , pp. 750-754
    • Salz, J.J.1    Azen, S.P.2    Berstein, J.3    Caroline, P.4    Vitlasenor, R.A.5    Schanzlin, D.J.6
  • 24
    • 0025072739 scopus 로고
    • Ablation rate of human corneal epithelium and Bowman's layer with the excimer laser
    • Seiler T, Kriegeowski M, Schnoy N, Bende T. Ablation rate of human corneal epithelium and Bowman's layer with the excimer laser. Refract Corneal Surg 1990; 6:99-102
    • (1990) Refract Corneal Surg , vol.6 , pp. 99-102
    • Seiler, T.1    Kriegeowski, M.2    Schnoy, N.3    Bende, T.4
  • 26
    • 7144233554 scopus 로고    scopus 로고
    • Rapid and precise in vivo measurement of human corneal thickness with optocal low-coherence reflectometry in normal human eyes
    • in press
    • Wälti R, Gianotti R, Bonvin P, Ballif J, Salathé RP, Böhnke M. Rapid and precise in vivo measurement of human corneal thickness with optocal low-coherence reflectometry in normal human eyes. J Biomed Optics 1997. in press
    • (1997) J Biomed Optics
    • Wälti, R.1    Gianotti, R.2    Bonvin, P.3    Ballif, J.4    Salathé, R.P.5    Böhnke, M.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.