메뉴 건너뛰기




Volumn 16, Issue 3, 2006, Pages 180-187

Application of normoxic polymer gels in 3D-dosimetry for radiosurgery;Einsatz normoxischer polymergele in der 3D-dosimetrie für die radiochirurgie

Author keywords

Dose verification; Dosimetry; Polymer gel; Radiosurgery

Indexed keywords

POLYMER;

EID: 33748548370     PISSN: 09393889     EISSN: None     Source Type: Journal    
DOI: 10.1078/0939-3889-00313     Document Type: Article
Times cited : (3)

References (15)
  • 1
    • 0032726836 scopus 로고    scopus 로고
    • Uncertainty analysis in polymer gel dosimetry
    • Baldock, C., Murry, P., Kron, T.: Uncertainty Analysis in Polymer Gel Dosimetry. Phys. Med. Biol. 44 (1999) N243-N246
    • (1999) Phys. Med. Biol. , vol.44
    • Baldock, C.1    Murry, P.2    Kron, T.3
  • 2
    • 0035016596 scopus 로고    scopus 로고
    • High resolution polymer gel dosimetry by parameter selective MR-microimaging on a whole body scanner at 3 T
    • Berg, A., Ertl, A., Moser, E.: High resolution polymer gel dosimetry by parameter selective MR-microimaging on a whole body scanner at 3 T. Medical Physics 28 (2001) 833-843
    • (2001) Medical Physics , vol.28 , pp. 833-843
    • Berg, A.1    Ertl, A.2    Moser, E.3
  • 3
    • 4544235453 scopus 로고    scopus 로고
    • High resolution MR based polymer dosimetry versus film densitometry: A systematic study based on the modulation transfer function approach
    • Berg, A., Pernkopf, M., Waldhausl, C., Schmidt, W., Moser, E.: High resolution MR based polymer dosimetry versus film densitometry: a systematic study based on the modulation transfer function approach. Phys. Med. Biol. 49 (2004) 4087-4108
    • (2004) Phys. Med. Biol. , vol.49 , pp. 4087-4108
    • Berg, A.1    Pernkopf, M.2    Waldhausl, C.3    Schmidt, W.4    Moser, E.5
  • 4
    • 0037151132 scopus 로고    scopus 로고
    • Dose-response stability and integrity of the dose distribution of various polymer gel dosimeters
    • De Deene, Y., Venning, A., Hurley, C., Healy, B.J., Baldock, C.: Dose-response stability and integrity of the dose distribution of various polymer gel dosimeters. Phys. Med. Biol. 47 (2002) 2459-2470
    • (2002) Phys. Med. Biol. , vol.47 , pp. 2459-2470
    • De Deene, Y.1    Venning, A.2    Hurley, C.3    Healy, B.J.4    Baldock, C.5
  • 6
    • 0034104588 scopus 로고    scopus 로고
    • High-resolution dose profile studies based on MR imaging with polymer BANG™ gels in stereotactic radiation techniques
    • Ertl, A., Berg, A., Zehetmayer, M., Frigo, P.: High-resolution dose profile studies based on MR imaging with polymer BANG™ gels in stereotactic radiation techniques. Magn. Reson. Imaging 18 (2000) 343-349
    • (2000) Magn. Reson. Imaging , vol.18 , pp. 343-349
    • Ertl, A.1    Berg, A.2    Zehetmayer, M.3    Frigo, P.4
  • 7
    • 0035739868 scopus 로고    scopus 로고
    • Polymer gels for magnetic resonance imaging of radiation dose distributions at normal room atmosphere
    • Fong, P.M., Keil, D.C., Does, M.D., Gore, J.C.: Polymer gels for magnetic resonance imaging of radiation dose distributions at normal room atmosphere. Phys. Med. Biol. 46 (2001) 3105-3113
    • (2001) Phys. Med. Biol. , vol.46 , pp. 3105-3113
    • Fong, P.M.1    Keil, D.C.2    Does, M.D.3    Gore, J.C.4
  • 8
    • 0021232591 scopus 로고
    • Measurement of radiation dose distributions by nuclear magnetic resonance (NMR) imaging
    • Gore, J.C., Kang, Y.S., Schulz, R.J.: Measurement of radiation dose distributions by nuclear magnetic resonance (NMR) imaging. Phys. Med. Biol. 29 (1984) 1189-1197
    • (1984) Phys. Med. Biol. , vol.29 , pp. 1189-1197
    • Gore, J.C.1    Kang, Y.S.2    Schulz, R.J.3
  • 9
    • 0037732932 scopus 로고    scopus 로고
    • MAGIC-type polymer gel for three-dimensional dosimetry: Intensity-modulated radiation therapy verification
    • Gustavsson, H., Karlsson, A., Haraldsson, P., Engström, P., Bäck, S., Nyström, H., Olsson, L.E.: MAGIC-type Polymer Gel for Three-Dimensional Dosimetry: Intensity-Modulated Radiation Therapy Verification. Med. Phys. 30 (2003) 1264-1271
    • (2003) Med. Phys. , vol.30 , pp. 1264-1271
    • Gustavsson, H.1    Karlsson, A.2    Haraldsson, P.3    Engström, P.4    Bäck, S.5    Nyström, H.6    Olsson, L.E.7
  • 10
    • 0031861573 scopus 로고    scopus 로고
    • A technique for the quantitative evaluation of dose distribution
    • Low, D., Harms, W., Mutic, S., Purdy, J.: A Technique for the quantitative Evaluation of Dose Distribution. Med. Phys. 25 (1998) 656-661
    • (1998) Med. Phys. , vol.25 , pp. 656-661
    • Low, D.1    Harms, W.2    Mutic, S.3    Purdy, J.4
  • 11
    • 0029933012 scopus 로고    scopus 로고
    • Radiation therapy dosimetry using resonance imaging of polymer gels
    • Maryanski, M.J., Ibbott, G.S., Eastman, P., Schulz, R.J., Gore, J.C.: Radiation therapy dosimetry using resonance imaging of polymer gels. Med. Phys. 23 (1996) 699-705
    • (1996) Med. Phys. , vol.23 , pp. 699-705
    • Maryanski, M.J.1    Ibbott, G.S.2    Eastman, P.3    Schulz, R.J.4    Gore, J.C.5
  • 12
    • 0037152449 scopus 로고    scopus 로고
    • A systematic review of the precision and accuracy of dose measurements in photon radiotherapy using polymer and Fricke MRI gel dosimetry
    • MacDougall et al.: A systematic review of the precision and accuracy of dose measurements in photon radiotherapy using polymer and Fricke MRI gel dosimetry Phys. Med. Biol. 47 (2002) R107-R121
    • (2002) Phys. Med. Biol. , vol.47
    • MacDougall1
  • 13


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.