Volumn 28, Issue 5, 2001, Pages 833-843

High resolution polymer gel dosimetry by parameter selective MR-microimaging on a whole body scanner at 3 T

Author keywords

Dosimetry; MR microimaging; Polymer gel; Radiosurgery; Relaxation

Indexed keywords

DIFFUSION; GELS; IMAGE RESOLUTION; IRRADIATION; MAGNETIC RESONANCE IMAGING; POLYMERS; RADIOTHERAPY;

EID: 0035016596     PISSN: 00942405     EISSN: None     Source Type: Journal    
DOI: 10.1118/1.1358304     Document Type: Article
Times cited : (38)

References (26)
  • 1
    • 0004116648 scopus 로고
    • edited by F. H. Attix and W. C. Roesch New York, Academic, New York
    • H. Fricke and E. J. Hart, in Radiation Dosimetry, edited by F. H. Attix and W. C. Roesch (New York, Academic, New York, 1966), Vol. 2.
    • (1966) Radiation Dosimetry , vol.2
    • Fricke, H.1    Hart, E.J.2
  • 2
    • 0021232591 scopus 로고
    • Measurement of radiation dose distributions by nuclear magnetic resonance imaging
    • J. C. Gore, Y. S. Kang, and R. J. Schulz, "Measurement of radiation dose distributions by nuclear magnetic resonance imaging," Phys. Med. Biol. 29, 1189-1197 (1984).
    • (1984) Phys. Med. Biol. , vol.29 , pp. 1189-1197
    • Gore, J.C.1    Kang, Y.S.2    Schulz, R.J.3
  • 4
    • 0029941612 scopus 로고    scopus 로고
    • An automated fast MR-imaging method for localized measurements of dose distributions using NMR-Fricke gel dosimetry
    • B. Reichl, D. Matthaei, J. Richter, and A. Haase, "An automated fast MR-imaging method for localized measurements of dose distributions using NMR-Fricke gel dosimetry," Strahlenther. Onkol. 172, 312-319 (1996).
    • (1996) Strahlenther. Onkol. , vol.172 , pp. 312-319
    • Reichl, B.1    Matthaei, D.2    Richter, J.3    Haase, A.4
  • 5
    • 0031950630 scopus 로고    scopus 로고
    • Experimental procedure for the manufacture and calibration of polyacrylamide gel (PAG) for magnetic resonance imaging (MRI) radiation dosimetry
    • C. Baldock, R. P. Burford, N. Billingham, G. S. Wagner, S. Patval, R. D. Badawi, and S. F. Keevil, "Experimental procedure for the manufacture and calibration of polyacrylamide gel (PAG) for magnetic resonance imaging (MRI) radiation dosimetry," Phys. Med. Biol. 43, 695-702 (1998).
    • (1998) Phys. Med. Biol. , vol.43 , pp. 695-702
    • Baldock, C.1    Burford, R.P.2    Billingham, N.3    Wagner, G.S.4    Patval, S.5    Badawi, R.D.6    Keevil, S.F.7
  • 6
    • 0032413559 scopus 로고    scopus 로고
    • Magnetic resonance imaging of microbubbles in a superheated emulsion chamber for brachytherapy dosimetry
    • M. Lamba, S. K. Holland, H. Elson, F. d' Ericco, and R. Nath, "Magnetic resonance imaging of microbubbles in a superheated emulsion chamber for brachytherapy dosimetry," Med. Phys. 25, 2316-2325 (1998).
    • (1998) Med. Phys. , vol.25 , pp. 2316-2325
    • Lamba, M.1    Holland, S.K.2    Elson, H.3    D' Ericco, F.4    Nath, R.5
  • 7
    • 0031691208 scopus 로고    scopus 로고
    • Optical CT reconstruction of 3D dose distributions using the ferrous benzoic-xylenol (FBX) gel dosimeter
    • R. G. Kelly, K. J. Jordan, and J. J. Battista, "Optical CT reconstruction of 3D dose distributions using the ferrous benzoic-xylenol (FBX) gel dosimeter," Med. Phys. 25, 1741-1750 (1998).
    • (1998) Med. Phys. , vol.25 , pp. 1741-1750
    • Kelly, R.G.1    Jordan, K.J.2    Battista, J.J.3
  • 8
    • 0027258459 scopus 로고
    • NMR relaxation enhancement in gels polymerized and cross-linked by ionizing radiation: A new approach to 3-D dosimetry by MRI
    • M. J. Maryanski, J. C. Gore, R. P. Kennan, and R. J. Schulz, "NMR relaxation enhancement in gels polymerized and cross-linked by ionizing radiation: A new approach to 3-D dosimetry by MRI," Magn. Reson. Imaging 11, 253-258 (1993).
    • (1993) Magn. Reson. Imaging , vol.11 , pp. 253-258
    • Maryanski, M.J.1    Gore, J.C.2    Kennan, R.P.3    Schulz, R.J.4
  • 10
    • 0029933012 scopus 로고    scopus 로고
    • Radiation therapy dosimetry using magnetic resonance imaging of polymer gels
    • M. J. Maryanski, G. S. Ibbott, P. Eastman, R. J. Schulz, and J. C. Gore, "Radiation therapy dosimetry using magnetic resonance imaging of polymer gels," Med. Phys. 23, 699-705 (1996).
    • (1996) Med. Phys. , vol.23 , pp. 699-705
    • Maryanski, M.J.1    Ibbott, G.S.2    Eastman, P.3    Schulz, R.J.4    Gore, J.C.5
  • 13
    • 0031044393 scopus 로고    scopus 로고
    • Effects of crosslinking and temperature on the dose response of a BANG polymer gel dosimeter
    • M. J. Maryanski, C. Audet, and J. C. Gore, "Effects of crosslinking and temperature on the dose response of a BANG polymer gel dosimeter," Phys. Med. Biol. 42, 303-311 (1997).
    • (1997) Phys. Med. Biol. , vol.42 , pp. 303-311
    • Maryanski, M.J.1    Audet, C.2    Gore, J.C.3
  • 14
    • 0032178596 scopus 로고    scopus 로고
    • Mathematical analysis and experimental investigation of noise in quantitative magnetic resonance imaging applied in polymer gel dosimetry
    • Y. DeDeene, R. VandeWalle, E. Achten, and C. DeWagter, "Mathematical analysis and experimental investigation of noise in quantitative magnetic resonance imaging applied in polymer gel dosimetry," Signal Process. 70, 85-101 (1998).
    • (1998) Signal Process. , vol.70 , pp. 85-101
    • DeDeene, Y.1    Vandewalle, R.2    Achten, E.3    DeWagter, C.4
  • 16
    • 33744639305 scopus 로고    scopus 로고
    • High resolution dosimetry for brachytherapeutic β-sources by means of T2 selective MR microscopy on polymer-gels
    • A. Berg, W. Schmidt, and E. Moser, "High resolution dosimetry for brachytherapeutic β-sources by means of T2 selective MR microscopy on polymer-gels," Magn. Reson. Mater. Phys., Biol., Med., Suppl. 1 8, 201-202 (1999).
    • (1999) Magn. Reson. Mater. Phys., Biol., Med., Suppl. 1 , vol.8 , pp. 201-202
    • Berg, A.1    Schmidt, W.2    Moser, E.3
  • 17
    • 0012741458 scopus 로고    scopus 로고
    • T2-selective NMR-microscopy on polymer-gels for dosimetry at high spatial resolutions
    • Philadelphia
    • A. Berg, A. Ertl, and E. Moser "T2-selective NMR-microscopy on polymer-gels for dosimetry at high spatial resolutions," Proceedings of the seventh annual meeting ISMRM, Philadelphia, 1999, Vol. 3, p. 2131.
    • (1999) Proceedings of the Seventh Annual Meeting ISMRM , vol.3 , pp. 2131
    • Berg, A.1    Ertl, A.2    Moser, E.3
  • 18
    • 0034104588 scopus 로고    scopus 로고
    • High-resolution dose profile studies based on MR Imaging with polymer BANG™ gels in stereotactic radiation techniques
    • A. Ertl, A. Berg, M. Zehetmayer, and P. Frigo, "High-resolution dose profile studies based on MR Imaging with polymer BANG™ gels in stereotactic radiation techniques," Magn. Reson. Imaging 18, 343-349 (2000).
    • (2000) Magn. Reson. Imaging , vol.18 , pp. 343-349
    • Ertl, A.1    Berg, A.2    Zehetmayer, M.3    Frigo, P.4
  • 19
    • 85012577031 scopus 로고
    • Principles and application of self-diffusion measurements by nuclear magnetic resonance
    • edited by J. S. Waugh Academic, San Diego
    • J. Kärger, H. Pfeifer, and W. Heink "Principles and application of self-diffusion measurements by nuclear magnetic resonance, in Advances in Magnetic Resonance, edited by J. S. Waugh (Academic, San Diego, 1988), Vol. 12, pp. 1-89.
    • (1988) Advances in Magnetic Resonance , vol.12 , pp. 1-89
    • Kärger, J.1    Pfeifer, H.2    Heink, W.3
  • 24
    • 33745930076 scopus 로고
    • Relaxation effects in nuclear magnetic resonance absorption
    • N. Bloembergen, E. M. Purcell, and R. V. Pound, "Relaxation effects in nuclear magnetic resonance absorption," Phys. Rev. 73, 679 (1948).
    • (1948) Phys. Rev. , vol.73 , pp. 679
    • Bloembergen, N.1    Purcell, E.M.2    Pound, R.V.3
  • 25
    • 0027290704 scopus 로고
    • Properties of the phase-alternating phase-shift multiple spin-echo protocol in MRI: A study of the effects of imperfect RF pulses
    • A. Fransson, A. Ericsson, B. Jung, and G. O. Sperber, "Properties of the phase-alternating phase-shift multiple spin-echo protocol in MRI: A study of the effects of imperfect RF pulses," Magn. Reson. Imaging 11, 771-784 (1993).
    • (1993) Magn. Reson. Imaging , vol.11 , pp. 771-784
    • Fransson, A.1    Ericsson, A.2    Jung, B.3    Sperber, G.O.4
  • 26
    • 0023164952 scopus 로고
    • Errors in T2 estimation using multislice multiple-echo imaging
    • A. P. Crawley and R. M. Henkelman, "Errors in T2 estimation using multislice multiple-echo imaging," Magn. Reson. Med. 4, 34-47 (1987).
    • (1987) Magn. Reson. Med. , vol.4 , pp. 34-47
    • Crawley, A.P.1    Henkelman, R.M.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.