메뉴 건너뛰기




Volumn 56, Issue 3, 2006, Pages 704-708

Reduction of reconstruction time for time-resolved spiral 3D contrast-enhanced magnetic resonance angiography using parallel computing

Author keywords

Contrast enhanced magnetic resonance angiography; High performance computing; Inhomogeneity correction; Parallel computing; Spiral trajectory

Indexed keywords

ANGIOGRAPHY; MAGNETIC RESONANCE; PARALLEL PROCESSING SYSTEMS;

EID: 33748370096     PISSN: 07403194     EISSN: 15222594     Source Type: Journal    
DOI: 10.1002/mrm.21004     Document Type: Article
Times cited : (12)

References (15)
  • 3
    • 0033984786 scopus 로고    scopus 로고
    • Undersampled projection-reconstruction imaging for time-resolved contrast-enhanced imaging
    • Vigen KK, Peters DC, Grist TM, Block WF, Mistretta CA. Undersampled projection-reconstruction imaging for time-resolved contrast-enhanced imaging. Magn Reson Med 2000;43:170-176.
    • (2000) Magn Reson Med , vol.43 , pp. 170-176
    • Vigen, K.K.1    Peters, D.C.2    Grist, T.M.3    Block, W.F.4    Mistretta, C.A.5
  • 4
    • 4644262669 scopus 로고    scopus 로고
    • High temporal and spatial resolution 4D MRA using spiral data sampling and sliding window reconstruction
    • Zhu H, Buck DG, Zhang Z, Zhang H, Wang P, Stenger VA, Prince MR, Wang Y. High temporal and spatial resolution 4D MRA using spiral data sampling and sliding window reconstruction. Magn Reson Med 2004;52:14-18.
    • (2004) Magn Reson Med , vol.52 , pp. 14-18
    • Zhu, H.1    Buck, D.G.2    Zhang, Z.3    Zhang, H.4    Wang, P.5    Stenger, V.A.6    Prince, M.R.7    Wang, Y.8
  • 7
    • 0030243005 scopus 로고    scopus 로고
    • A high-performance, portable implementation of the MPI message passing interface standard
    • Gropp W, Lusk E, Doss N, Skjellum A. A high-performance, portable implementation of the MPI message passing interface standard. Parallel Comput 1996;22:789-828.
    • (1996) Parallel Comput , vol.22 , pp. 789-828
    • Gropp, W.1    Lusk, E.2    Doss, N.3    Skjellum, A.4
  • 8
    • 20744449792 scopus 로고    scopus 로고
    • The design and implementation of FFTW3
    • Frigo M, Johnson SG. The design and implementation of FFTW3. Proc IEEE 2005;93:216-231.
    • (2005) Proc IEEE , vol.93 , pp. 216-231
    • Frigo, M.1    Johnson, S.G.2
  • 11
    • 0030982409 scopus 로고    scopus 로고
    • Simultaneous acquisition of spatial harmonics (SMASH): Fast imaging with radiofrequency coil arrays
    • Sodickson DK, Manning WJ. Simultaneous acquisition of spatial harmonics (SMASH): fast imaging with radiofrequency coil arrays. Magn Reson Med 1997;38:591-603.
    • (1997) Magn Reson Med , vol.38 , pp. 591-603
    • Sodickson, D.K.1    Manning, W.J.2
  • 14
  • 15
    • 0036319895 scopus 로고    scopus 로고
    • Time-resolved contrast-enhanced imaging with isotropic resolution and broad coverage using an undersampled 3D projection trajectory
    • Barger AV, Block WF, Toropov Y, Grist TM, Mistretta CA. Time-resolved contrast-enhanced imaging with isotropic resolution and broad coverage using an undersampled 3D projection trajectory. Magn Reson Med 2002;48:297-305.
    • (2002) Magn Reson Med , vol.48 , pp. 297-305
    • Barger, A.V.1    Block, W.F.2    Toropov, Y.3    Grist, T.M.4    Mistretta, C.A.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.