-
1
-
-
7244249950
-
Death by hyperventilation: a common and life-threatening problem during cardiopulmonary resuscitation
-
Aufderheide T.P., and Lurie K.G. Death by hyperventilation: a common and life-threatening problem during cardiopulmonary resuscitation. Crit Care Med 32 Suppl. 9 (2004) S345-S351
-
(2004)
Crit Care Med
, vol.32
, Issue.SUPPL. 9
-
-
Aufderheide, T.P.1
Lurie, K.G.2
-
2
-
-
0023369110
-
Ventilation performance using a self-inflating anesthesia bag: effect of operator characteristics
-
Augustine J.A., Seidel D.R., and McCabe J.B. Ventilation performance using a self-inflating anesthesia bag: effect of operator characteristics. Am J Emerg Med 5 4 (1987) 267-270
-
(1987)
Am J Emerg Med
, vol.5
, Issue.4
, pp. 267-270
-
-
Augustine, J.A.1
Seidel, D.R.2
McCabe, J.B.3
-
3
-
-
0022444190
-
Ventilation skills of emergency medical technicians: a teaching challenge for emergency medicine
-
Cummins R.O., Austin D., Graves J.R., Litwin P.E., and Pierce J. Ventilation skills of emergency medical technicians: a teaching challenge for emergency medicine. Ann Emerg Med 15 10 (1986) 1187-1192
-
(1986)
Ann Emerg Med
, vol.15
, Issue.10
, pp. 1187-1192
-
-
Cummins, R.O.1
Austin, D.2
Graves, J.R.3
Litwin, P.E.4
Pierce, J.5
-
5
-
-
22144497194
-
Reducing ventilation frequency during cardiopulmonary resuscitation in a porcine model of cardiac arrest
-
Yannopoulos D., Tang W., Roussos C., Aufderheide T.P., Idris A.H., and Lurie K.G. Reducing ventilation frequency during cardiopulmonary resuscitation in a porcine model of cardiac arrest. Respir Care 50 5 (2005) 628-635
-
(2005)
Respir Care
, vol.50
, Issue.5
, pp. 628-635
-
-
Yannopoulos, D.1
Tang, W.2
Roussos, C.3
Aufderheide, T.P.4
Idris, A.H.5
Lurie, K.G.6
-
6
-
-
0029088714
-
Does hypoxia or hypercarbia independently affect resuscitation from cardiac arrest?
-
Idris A.H., Wenzel V., Becker L.B., Banner M.J., and Orban D.J. Does hypoxia or hypercarbia independently affect resuscitation from cardiac arrest?. Chest 108 2 (1995) 522-528
-
(1995)
Chest
, vol.108
, Issue.2
, pp. 522-528
-
-
Idris, A.H.1
Wenzel, V.2
Becker, L.B.3
Banner, M.J.4
Orban, D.J.5
-
7
-
-
12244295495
-
Quality of cardiopulmonary resuscitation during out-of-hospital cardiac arrest
-
Wik L., Kramer-Johansen J., Myklebust H., Sorebo H., Svensson L., Fellows B., et al. Quality of cardiopulmonary resuscitation during out-of-hospital cardiac arrest. JAMA 293 3 (2005) 299-304
-
(2005)
JAMA
, vol.293
, Issue.3
, pp. 299-304
-
-
Wik, L.1
Kramer-Johansen, J.2
Myklebust, H.3
Sorebo, H.4
Svensson, L.5
Fellows, B.6
-
8
-
-
12244267087
-
Quality of cardiopulmonary resuscitation during in-hospital cardiac arrest
-
Abella B.S., Alvarado J.P., Myklebust H., Edelson D.P., Barry A., O'Hearn N., et al. Quality of cardiopulmonary resuscitation during in-hospital cardiac arrest. JAMA 293 3 (2005) 305-310
-
(2005)
JAMA
, vol.293
, Issue.3
, pp. 305-310
-
-
Abella, B.S.1
Alvarado, J.P.2
Myklebust, H.3
Edelson, D.P.4
Barry, A.5
O'Hearn, N.6
-
9
-
-
0020967694
-
Measurement of ventilation during cardiopulmonary resuscitation
-
Ornato J.P., Bryson B.L., Donovan P.J., Farquharson R.R., and Jaeger C. Measurement of ventilation during cardiopulmonary resuscitation. Crit Care Med 11 2 (1983) 79-82
-
(1983)
Crit Care Med
, vol.11
, Issue.2
, pp. 79-82
-
-
Ornato, J.P.1
Bryson, B.L.2
Donovan, P.J.3
Farquharson, R.R.4
Jaeger, C.5
-
10
-
-
0000021227
-
Guidelines for cardiopulmonary resuscitation emergency cardiovascular care
-
American Heart Association. Guidelines for cardiopulmonary resuscitation emergency cardiovascular care. Circulation 102 Suppl. I (2000) I-1-I-384
-
(2000)
Circulation
, vol.102
, Issue.SUPPL. I
, pp. 1-384
-
-
American Heart Association1
-
11
-
-
0033181291
-
Thoracic electrical impedance tomographic measurements during volume controlled ventilation-effects of tidal volume and positive end-expiratory pressure
-
Frerichs I., Hahn G., and Hellige G. Thoracic electrical impedance tomographic measurements during volume controlled ventilation-effects of tidal volume and positive end-expiratory pressure. IEEE Trans Med Imag 18 9 (1999) 764-773
-
(1999)
IEEE Trans Med Imag
, vol.18
, Issue.9
, pp. 764-773
-
-
Frerichs, I.1
Hahn, G.2
Hellige, G.3
-
12
-
-
2442673375
-
Accurate, noninvasive continuous monitoring of cardiac output by whole-body electrical bioimpedance
-
Cotter G., Moshkovitz Y., Kaluski E., Cohen A.J., Miller H., Goor D., et al. Accurate, noninvasive continuous monitoring of cardiac output by whole-body electrical bioimpedance. Chest 125 4 (2004) 1431-1440
-
(2004)
Chest
, vol.125
, Issue.4
, pp. 1431-1440
-
-
Cotter, G.1
Moshkovitz, Y.2
Kaluski, E.3
Cohen, A.J.4
Miller, H.5
Goor, D.6
-
14
-
-
0034834621
-
Outcome prediction of emergency patients by noninvasive hemodynamic monitoring
-
Shoemaker W.C., Wo C.C., Chan L., Ramicone E., Kamel E.S., Velmahos G.C., et al. Outcome prediction of emergency patients by noninvasive hemodynamic monitoring. Chest 120 2 (2001) 528-537
-
(2001)
Chest
, vol.120
, Issue.2
, pp. 528-537
-
-
Shoemaker, W.C.1
Wo, C.C.2
Chan, L.3
Ramicone, E.4
Kamel, E.S.5
Velmahos, G.C.6
-
15
-
-
0031195018
-
Comparison of impedance and inductance ventilation sensors on adults during breathing, motion, and simulated airway obstruction
-
Cohen K.P., Ladd W.M., Beams D.M., Sheers W.S., Radwin R.G., Tompkins W.J., et al. Comparison of impedance and inductance ventilation sensors on adults during breathing, motion, and simulated airway obstruction. IEEE Trans Biomed Eng 44 7 (1997) 555-566
-
(1997)
IEEE Trans Biomed Eng
, vol.44
, Issue.7
, pp. 555-566
-
-
Cohen, K.P.1
Ladd, W.M.2
Beams, D.M.3
Sheers, W.S.4
Radwin, R.G.5
Tompkins, W.J.6
-
16
-
-
0036214071
-
Expanding automatic external defibrillators to include automated detection of cardiac, respiratory, and cardiorespiratory arrest
-
Pellis T., Bisera J., Tang W., and Weil M.H. Expanding automatic external defibrillators to include automated detection of cardiac, respiratory, and cardiorespiratory arrest. Crit Care Med 30 Suppl. 4 (2002) S176-S178
-
(2002)
Crit Care Med
, vol.30
, Issue.SUPPL. 4
-
-
Pellis, T.1
Bisera, J.2
Tang, W.3
Weil, M.H.4
-
17
-
-
0032940897
-
Impedance pneumography: noise as signal in impedance cardiography
-
Ernst J.M., Litvack D.A., Lozano D.L., Cacioppo J.T., and Berntson G.G. Impedance pneumography: noise as signal in impedance cardiography. Psychophysiology 36 3 (1999) 333-338
-
(1999)
Psychophysiology
, vol.36
, Issue.3
, pp. 333-338
-
-
Ernst, J.M.1
Litvack, D.A.2
Lozano, D.L.3
Cacioppo, J.T.4
Berntson, G.G.5
-
18
-
-
12144287431
-
Imbalances in regional lung ventilation: a validation study on electrical impedance tomography
-
Victorino J.A., Borges J.B., Okamoto V.N., Matos G.F.J., Tucci M.R., Caramez M.P.R., et al. Imbalances in regional lung ventilation: a validation study on electrical impedance tomography. Am J Respir Crit Care Med 169 7 (2004) 791-800
-
(2004)
Am J Respir Crit Care Med
, vol.169
, Issue.7
, pp. 791-800
-
-
Victorino, J.A.1
Borges, J.B.2
Okamoto, V.N.3
Matos, G.F.J.4
Tucci, M.R.5
Caramez, M.P.R.6
-
19
-
-
0030657934
-
Monitoring changes in lung air and liquid volumes with electrical impedance tomography
-
Adler A., Amyot R., Guardo R., Bates J.H., and Berthiaume Y. Monitoring changes in lung air and liquid volumes with electrical impedance tomography. J Appl Physiol 83 5 (1997) 1762-1767
-
(1997)
J Appl Physiol
, vol.83
, Issue.5
, pp. 1762-1767
-
-
Adler, A.1
Amyot, R.2
Guardo, R.3
Bates, J.H.4
Berthiaume, Y.5
-
20
-
-
0034527053
-
Monitoring of recruitment and derecruitment by electrical impedance tomography in a model of acute lung injury
-
Kunst P.W., Vazquez de Anda G., Bohm S.H., Faes T.J., Lachmann B., Postmus P.E., et al. Monitoring of recruitment and derecruitment by electrical impedance tomography in a model of acute lung injury. Crit Care Med 28 12 (2000) 3891-3895
-
(2000)
Crit Care Med
, vol.28
, Issue.12
, pp. 3891-3895
-
-
Kunst, P.W.1
Vazquez de Anda, G.2
Bohm, S.H.3
Faes, T.J.4
Lachmann, B.5
Postmus, P.E.6
-
21
-
-
13344262689
-
Three-dimensional electrical impedance tomography
-
Metherall P., Barber D.C., Smallwood R.H., and Brown B.H. Three-dimensional electrical impedance tomography. Nature 380 6574 (1996) 509-512
-
(1996)
Nature
, vol.380
, Issue.6574
, pp. 509-512
-
-
Metherall, P.1
Barber, D.C.2
Smallwood, R.H.3
Brown, B.H.4
-
22
-
-
0344773715
-
Bedside detection of regional opening/closing pressures by electrical impedance vs. computed tomography (CT)
-
Borges J.B., Okamoto V.N., Tanaka H., Janot G.F., Victorino J.A., Tucci M.R., et al. Bedside detection of regional opening/closing pressures by electrical impedance vs. computed tomography (CT). Am J Respir Crit Care Med 163 (2001) A755
-
(2001)
Am J Respir Crit Care Med
, vol.163
-
-
Borges, J.B.1
Okamoto, V.N.2
Tanaka, H.3
Janot, G.F.4
Victorino, J.A.5
Tucci, M.R.6
-
23
-
-
0019195740
-
Non-invasive measurement of ventilation during exercise using a respiratory inductive plethysmograph
-
Sackner J.D., Nison A.J., Davis B., Atkins N., and Sackner M.A. Non-invasive measurement of ventilation during exercise using a respiratory inductive plethysmograph. Am Rev Respir Dis 122 6 (1980) 867-871
-
(1980)
Am Rev Respir Dis
, vol.122
, Issue.6
, pp. 867-871
-
-
Sackner, J.D.1
Nison, A.J.2
Davis, B.3
Atkins, N.4
Sackner, M.A.5
-
25
-
-
0027515971
-
Lung volumes and forced ventilatory flow. Report Working Party Standardization of Lung Function Tests, European Community for Steel and Coal. Official Statement of the European Respiratory Society
-
Quanjer P.H., Tammeling G.J., Cotes J.E., Pedersen O.F., Peslin R., and Yernault J.C. Lung volumes and forced ventilatory flow. Report Working Party Standardization of Lung Function Tests, European Community for Steel and Coal. Official Statement of the European Respiratory Society. Eur Respir J Suppl 16 (1993) 5-40
-
(1993)
Eur Respir J Suppl
, vol.16
, pp. 5-40
-
-
Quanjer, P.H.1
Tammeling, G.J.2
Cotes, J.E.3
Pedersen, O.F.4
Peslin, R.5
Yernault, J.C.6
-
26
-
-
0041828325
-
Continuous intravascular blood gas monitoring: development, current techniques, and clinical use of a commercial device
-
Ganter M., and Zollinger A. Continuous intravascular blood gas monitoring: development, current techniques, and clinical use of a commercial device. Br J Anaesth 91 3 (2003) 397-407
-
(2003)
Br J Anaesth
, vol.91
, Issue.3
, pp. 397-407
-
-
Ganter, M.1
Zollinger, A.2
-
27
-
-
0028059615
-
Usefulness of central venous oxygen saturation monitoring during cardiopulmonary resuscitation. A comparative case study with end-tidal carbon dioxide monitoring
-
Nakazawa K., Hikawa Y., Saitoh Y., Tanaka N., Yasuda K., and Amaha K. Usefulness of central venous oxygen saturation monitoring during cardiopulmonary resuscitation. A comparative case study with end-tidal carbon dioxide monitoring. Intens Care Med 20 6 (1994) 450-451
-
(1994)
Intens Care Med
, vol.20
, Issue.6
, pp. 450-451
-
-
Nakazawa, K.1
Hikawa, Y.2
Saitoh, Y.3
Tanaka, N.4
Yasuda, K.5
Amaha, K.6
-
29
-
-
0032988618
-
Clinical use of continuous arterial blood gas monitoring in the pediatric intensive care unit
-
Weiss I.K., Fink S., Harrison R., Feldman J.D., and Brill J.E. Clinical use of continuous arterial blood gas monitoring in the pediatric intensive care unit. Pediatrics 103 2 (1999) 440-445
-
(1999)
Pediatrics
, vol.103
, Issue.2
, pp. 440-445
-
-
Weiss, I.K.1
Fink, S.2
Harrison, R.3
Feldman, J.D.4
Brill, J.E.5
-
31
-
-
26544441492
-
2 between asphyxia cardiac arrest and ventricular fibrillation/pulseless ventricular tachycardia cardiac arrest in the prehospital setting
-
2 between asphyxia cardiac arrest and ventricular fibrillation/pulseless ventricular tachycardia cardiac arrest in the prehospital setting. Crit Care 7 6 (2003) R139-R144
-
(2003)
Crit Care
, vol.7
, Issue.6
-
-
Grmec, S.1
Lah, K.2
Tusek-Bunc, K.3
-
32
-
-
0030840960
-
End-tidal carbon dioxide and outcome of out-of-hospital cardiac arrest
-
Levine R.L., Wayne M.A., and Miller C.C. End-tidal carbon dioxide and outcome of out-of-hospital cardiac arrest. N Engl J Med 337 5 (1997) 301-306
-
(1997)
N Engl J Med
, vol.337
, Issue.5
, pp. 301-306
-
-
Levine, R.L.1
Wayne, M.A.2
Miller, C.C.3
-
33
-
-
33748767526
-
Use of end-tidal carbon dioxide to predict outcome in prehospital cardiac arrest
-
Wayne M., Levine R., and Miller C. Use of end-tidal carbon dioxide to predict outcome in prehospital cardiac arrest. Resuscitation 31 1 (1996) 83
-
(1996)
Resuscitation
, vol.31
, Issue.1
, pp. 83
-
-
Wayne, M.1
Levine, R.2
Miller, C.3
-
34
-
-
0026538036
-
Multicenter study of a portable, hand-size, colorimetric end-tidal carbon dioxide detection device
-
Ornato J.P., Shipley J.B., Racht E.M., Slovis C.M., Wrenn K.D., Pepe P.E., et al. Multicenter study of a portable, hand-size, colorimetric end-tidal carbon dioxide detection device. Ann Emerg Med 21 5 (1992) 518-523
-
(1992)
Ann Emerg Med
, vol.21
, Issue.5
, pp. 518-523
-
-
Ornato, J.P.1
Shipley, J.B.2
Racht, E.M.3
Slovis, C.M.4
Wrenn, K.D.5
Pepe, P.E.6
-
35
-
-
0029942823
-
Prehospital monitoring of trauma patients: experience of a helicopter emergency medical service
-
Morley A.P. Prehospital monitoring of trauma patients: experience of a helicopter emergency medical service. Br J Anaesth 76 5 (1996) 726-730
-
(1996)
Br J Anaesth
, vol.76
, Issue.5
, pp. 726-730
-
-
Morley, A.P.1
-
36
-
-
20844437452
-
Using ventilator and cardiovascular graphics in the patient who is hemodynamically unstable
-
Murphy B.A., and Durbin C.G. Using ventilator and cardiovascular graphics in the patient who is hemodynamically unstable. Respir Care 50 2 (2005) 262-274
-
(2005)
Respir Care
, vol.50
, Issue.2
, pp. 262-274
-
-
Murphy, B.A.1
Durbin, C.G.2
-
37
-
-
17444420319
-
Measurement of air trapping, intrinsic positive end-expiratory pressure, and dynamic hyperinflation in mechanically ventilated patients
-
Blanch L., Bernabe F., and Lucangelo U. Measurement of air trapping, intrinsic positive end-expiratory pressure, and dynamic hyperinflation in mechanically ventilated patients. Respir Care 50 1 (2005) 110-123
-
(2005)
Respir Care
, vol.50
, Issue.1
, pp. 110-123
-
-
Blanch, L.1
Bernabe, F.2
Lucangelo, U.3
-
38
-
-
0030749823
-
Pulmonary hyperinflation and ventilator-dependent patients
-
Rossi A., Ganassini A., Polese G., and Grassi V. Pulmonary hyperinflation and ventilator-dependent patients. Eur Respir J 10 7 (1997) 1663-1674
-
(1997)
Eur Respir J
, vol.10
, Issue.7
, pp. 1663-1674
-
-
Rossi, A.1
Ganassini, A.2
Polese, G.3
Grassi, V.4
-
39
-
-
0014115848
-
Pleural and esophageal pressures in the upright body position
-
Banchero N., Schwartz P.E., Tsakiris A.G., and Wood E.H. Pleural and esophageal pressures in the upright body position. J Appl Physiol 23 2 (1967) 228-234
-
(1967)
J Appl Physiol
, vol.23
, Issue.2
, pp. 228-234
-
-
Banchero, N.1
Schwartz, P.E.2
Tsakiris, A.G.3
Wood, E.H.4
-
40
-
-
0038637799
-
Preload changes by positive pressure ventilation can be used for assessment of left ventricular systolic function
-
Sellgren J., Soderstrom S., Johansson G., Biber B., Haggmark S., and Ponten J. Preload changes by positive pressure ventilation can be used for assessment of left ventricular systolic function. Acta Anaesthesiol Scand 47 5 (2003) 541-548
-
(2003)
Acta Anaesthesiol Scand
, vol.47
, Issue.5
, pp. 541-548
-
-
Sellgren, J.1
Soderstrom, S.2
Johansson, G.3
Biber, B.4
Haggmark, S.5
Ponten, J.6
-
42
-
-
0034910810
-
Changes of aortic dimensions as evidence of cardiac pump mechanism during cardiopulmonary resuscitation in humans
-
Hwang S.O., Lee K.H., Cho J.H., Yoon J., and Choe K.H. Changes of aortic dimensions as evidence of cardiac pump mechanism during cardiopulmonary resuscitation in humans. Resuscitation 50 1 (2001) 87-93
-
(2001)
Resuscitation
, vol.50
, Issue.1
, pp. 87-93
-
-
Hwang, S.O.1
Lee, K.H.2
Cho, J.H.3
Yoon, J.4
Choe, K.H.5
-
43
-
-
0030612636
-
Echocardiographic observations during in hospital cardiopulmonary resuscitation
-
Varriale P., and Maldonado J.M. Echocardiographic observations during in hospital cardiopulmonary resuscitation. Crit Care Med 25 10 (1997) 1717-1720
-
(1997)
Crit Care Med
, vol.25
, Issue.10
, pp. 1717-1720
-
-
Varriale, P.1
Maldonado, J.M.2
-
44
-
-
0035856551
-
Adverse hemodynamic effects of interrupting chest compressions for rescue breathing during cardiopulmonary resuscitation for ventricular fibrillation cardiac arrest
-
Berg R.A., Sanders A.B., Kern K.B., Hilwig R.W., Heidenreich J.W., Porter M.E., et al. Adverse hemodynamic effects of interrupting chest compressions for rescue breathing during cardiopulmonary resuscitation for ventricular fibrillation cardiac arrest. Circulation 104 20 (2001) 2465-2470
-
(2001)
Circulation
, vol.104
, Issue.20
, pp. 2465-2470
-
-
Berg, R.A.1
Sanders, A.B.2
Kern, K.B.3
Hilwig, R.W.4
Heidenreich, J.W.5
Porter, M.E.6
-
45
-
-
0037118665
-
Adverse outcomes of interrupted precordial compressions during automated defibrillation
-
Yu T., Weil M.H., Tang W., Sun S., Klouche K., Povoas H., et al. Adverse outcomes of interrupted precordial compressions during automated defibrillation. Circulation 106 3 (2002) 368-372
-
(2002)
Circulation
, vol.106
, Issue.3
, pp. 368-372
-
-
Yu, T.1
Weil, M.H.2
Tang, W.3
Sun, S.4
Klouche, K.5
Povoas, H.6
-
46
-
-
0035686392
-
Emergency airway management by non-anesthesia house officers-a comparison of three strategies
-
Dorges V., Ocker H., Wenzel V., Sauer C., and Schmucker P. Emergency airway management by non-anesthesia house officers-a comparison of three strategies. Emerg Med J 18 2 (2001) 90-94
-
(2001)
Emerg Med J
, vol.18
, Issue.2
, pp. 90-94
-
-
Dorges, V.1
Ocker, H.2
Wenzel, V.3
Sauer, C.4
Schmucker, P.5
|