-
1
-
-
0026570956
-
A review of electronic portal imaging devices
-
A. L. Boyer, L. Antonuk, A. Fenster, H. M. van Meertens, P. Munro, L. E. Reinstein, and J. Wong, "A review of electronic portal imaging devices," Med. Phys. 19, 1-16 (1992).
-
(1992)
Med. Phys.
, vol.19
, pp. 1-16
-
-
Boyer, A.L.1
Antonuk, L.2
Fenster, A.3
Van Meertens, H.M.4
Munro, P.5
Reinstein, L.E.6
Wong, J.7
-
2
-
-
0028231781
-
Clinical use of on-line portal imaging for daily patient treatment verification
-
M. G. Herman, R. A. Abrams, and R. R. Mayer, "Clinical use of on-line portal imaging for daily patient treatment verification," Int. J. Radiat. Oncol., Biol., Phys. 28, 1017-1023 (1994).
-
(1994)
Int. J. Radiat. Oncol., Biol., Phys.
, vol.28
, pp. 1017-1023
-
-
Herman, M.G.1
Abrams, R.A.2
Mayer, R.R.3
-
3
-
-
0037149519
-
Electronic portal imaging devices: A review and historical perspective of contemporary technologies and research
-
L. Antonuk, "Electronic portal imaging devices: A review and historical perspective of contemporary technologies and research," Phys. Med. Biol. 47, R31-R65 (2002).
-
(2002)
Phys. Med. Biol.
, vol.47
-
-
Antonuk, L.1
-
4
-
-
0029585974
-
Portal dose measurement in radiotherapy using an electronic portal imaging device
-
B. J. M. Heijmen, K. L. Pasma, and M. Kroonwijk, "Portal dose measurement in radiotherapy using an electronic portal imaging device," Phys. Med. Biol. 40, 1943-1955 (1995).
-
(1995)
Phys. Med. Biol.
, vol.40
, pp. 1943-1955
-
-
Heijmen, B.J.M.1
Pasma, K.L.2
Kroonwijk, M.3
-
5
-
-
0002781107
-
Megavoltage radiotherapy for treatment verification
-
edited by J. van Dyk Medical Physics, Madison, WI, Chap. 13
-
P. Munro, "Megavoltage radiotherapy for treatment verification," in The Modern Technology of Radiation Oncology - A Compendium for Medical Physicists and Radiation Oncologists, edited by J. van Dyk (Medical Physics, Madison, WI, 1999), Chap. 13.
-
(1999)
The Modern Technology of Radiation Oncology - A Compendium for Medical Physicists and Radiation Oncologists
-
-
Munro, P.1
-
6
-
-
0008705949
-
A digital imaging system for portal verification
-
Elsevier, North Holland, Amsterdam
-
M. van Herk and H. Marteens, "A digital imaging system for portal verification," Proceedings of the 9th International Conference on the Use of Computers in Radiation Therapy (Elsevier, North Holland, Amsterdam, 1987), pp. 371-374.
-
(1987)
Proceedings of the 9th International Conference on the Use of Computers in Radiation Therapy
, pp. 371-374
-
-
Van Herk, M.1
Marteens, H.2
-
7
-
-
0023885087
-
A matrix ionization chamber imaging device for on-line patient set-up verification during radiotherapy
-
M. van Herk and H. Marteens, "A matrix ionization chamber imaging device for on-line patient set-up verification during radiotherapy," Radiother. Oncol. 11, 369-378 (1988).
-
(1988)
Radiother. Oncol.
, vol.11
, pp. 369-378
-
-
Van Herk, M.1
Marteens, H.2
-
8
-
-
0025331845
-
First clinical experience with a newly developed electronic portal imaging device
-
H. Meertens, H. van Herk, J. Bijhold, and H. Bartelink, "First clinical experience with a newly developed electronic portal imaging device," Int. J. Radiat. Oncol., Biol., Phys. 18, 1173-1181 (1990).
-
(1990)
Int. J. Radiat. Oncol., Biol., Phys.
, vol.18
, pp. 1173-1181
-
-
Meertens, H.1
Van Herk, H.2
Bijhold, J.3
Bartelink, H.4
-
9
-
-
0001374142
-
Amorphous silicon sensor arrays for radiation imaging
-
R. A. Street, S. Nelson, L. E. Antonuk, and P. Mendez, "Amorphous silicon sensor arrays for radiation imaging," Mater. Res. Soc. Symp. Proc. 192, 441-452 (1990).
-
(1990)
Mater. Res. Soc. Symp. Proc.
, vol.192
, pp. 441-452
-
-
Street, R.A.1
Nelson, S.2
Antonuk, L.E.3
Mendez, P.4
-
10
-
-
0026439069
-
Demonstration of megavoltage and diagnostic x-ray imaging with hydrogenated amorphous silicon arrays
-
L. E. Antonuk, J. Boudry, W. Huang, D. L. McShan, E. J. Morton, J. Yorkston, M. J. Longo, and R. A. Street, "Demonstration of megavoltage and diagnostic x-ray imaging with hydrogenated amorphous silicon arrays," Med. Phys. 19, 1455-1466 (1992).
-
(1992)
Med. Phys.
, vol.19
, pp. 1455-1466
-
-
Antonuk, L.E.1
Boudry, J.2
Huang, W.3
McShan, D.L.4
Morton, E.J.5
Yorkston, J.6
Longo, M.J.7
Street, R.A.8
-
11
-
-
0030272271
-
Megavoltage imaging with a large-area, flat-panel, amorphous silicon imager
-
L. E. Antonuk, J. Yorkston, W. Huang, H. Sandler, J. H. Siewerdsen, and Y. el-Mohri, "Megavoltage imaging with a large-area, flat-panel, amorphous silicon imager," Int. J. Radiat. Oncol., Biol., Phys. 36, 661-672 (1996).
-
(1996)
Int. J. Radiat. Oncol., Biol., Phys.
, vol.36
, pp. 661-672
-
-
Antonuk, L.E.1
Yorkston, J.2
Huang, W.3
Sandler, H.4
Siewerdsen, J.H.5
El-Mohri, Y.6
-
12
-
-
0003325039
-
A prototype amorphous silicon array based radiotherapy portal imager
-
D. J. Drake, D. A. Jaffray, and J. Wong, "A prototype amorphous silicon array based radiotherapy portal imager," Proc. SPIE 3032, 32-41 (1997).
-
(1997)
Proc. SPIE
, vol.3032
, pp. 32-41
-
-
Drake, D.J.1
Jaffray, D.A.2
Wong, J.3
-
13
-
-
0031443148
-
Modulation transfer function for a large area amorphous silicon image receptor
-
J. R. D. Earnhart and E. L. Chaney, "Modulation transfer function for a large area amorphous silicon image receptor," Phys. Med. Biol. 42, 2531-2540 (1997).
-
(1997)
Phys. Med. Biol.
, vol.42
, pp. 2531-2540
-
-
Earnhart, J.R.D.1
Chaney, E.L.2
-
14
-
-
0031860585
-
X-ray quantum limited portal imaging using amorphous silicon flat-panel arrays
-
P. Munro and D. C. Bouius, "X-ray quantum limited portal imaging using amorphous silicon flat-panel arrays," Med. Phys. 25, 689-702 (1998).
-
(1998)
Med. Phys.
, vol.25
, pp. 689-702
-
-
Munro, P.1
Bouius, D.C.2
-
15
-
-
0035661107
-
Determination of the detective quantum efficiency of a prototype mega-voltage indirect detection, active matrix flat-panel imager
-
Y. El-Mohri, K-W. Jee, L. E. Antonuk, M. Maolinbay, and Q. Zhao, "Determination of the detective quantum efficiency of a prototype mega-voltage indirect detection, active matrix flat-panel imager," Med. Phys. 28, 2538-2550 (2001).
-
(2001)
Med. Phys.
, vol.28
, pp. 2538-2550
-
-
El-Mohri, Y.1
Jee, K.-W.2
Antonuk, L.E.3
Maolinbay, M.4
Zhao, Q.5
-
16
-
-
0031831866
-
Preliminary study of a metal/a -Se based portal detector
-
T. Falco, H. Wang, and B. G. Fallone, "Preliminary study of a metal/a -Se based portal detector," Med. Phys. 25, 814-823 (1998).
-
(1998)
Med. Phys.
, vol.25
, pp. 814-823
-
-
Falco, T.1
Wang, H.2
Fallone, B.G.3
-
17
-
-
0031812917
-
Monte Carlo detective quantum efficiency and scatter studiesof a metal/a-Se portal detector
-
M. Lachaine and B. G. Fallone, "Monte Carlo detective quantum efficiency and scatter studiesof a metal/a-Se portal detector," Med. Phys. 25, 1186-1194 (1998).
-
(1998)
Med. Phys.
, vol.25
, pp. 1186-1194
-
-
Lachaine, M.1
Fallone, B.G.2
-
18
-
-
0031965711
-
Sensitivity of amorphous selenium to x-rays from 40 kVp to 18 MV: Measurements and implications for portal imaging
-
D. Mah, J. A. Rawlinson, and J. A. Rowlands, "Sensitivity of amorphous selenium to x-rays from 40 kVp to 18 MV: Measurements and implications for portal imaging," Med. Phys. 25, 444-456 (1998).
-
(1998)
Med. Phys.
, vol.25
, pp. 444-456
-
-
Mah, D.1
Rawlinson, J.A.2
Rowlands, J.A.3
-
19
-
-
0032939209
-
Detective quantum efficiency of an amorphous selenium detector to megavoltage radiation
-
D. Mah, J. A. Rawlinson, and J. A. Rowlands, "Detective quantum efficiency of an amorphous selenium detector to megavoltage radiation," Phys. Med. Biol. 44, 1369-1384 (1999).
-
(1999)
Phys. Med. Biol.
, vol.44
, pp. 1369-1384
-
-
Mah, D.1
Rawlinson, J.A.2
Rowlands, J.A.3
-
20
-
-
0034758086
-
Investigation of a direct conversion flat-panel imager for portal imaging
-
G. Pang, D. L. Lee, and J. A. Rowlands, "Investigation of a direct conversion flat-panel imager for portal imaging," Med. Phys. 28, 2121-2128 (2001).
-
(2001)
Med. Phys.
, vol.28
, pp. 2121-2128
-
-
Pang, G.1
Lee, D.L.2
Rowlands, J.A.3
-
21
-
-
0034917858
-
Detective quantum efficiency of a direct-detection active matrix flat panel imager at megavoltage energies
-
M. Lachaine, E. Fourkal, and B. G. Fallone, "Detective quantum efficiency of a direct-detection active matrix flat panel imager at megavoltage energies," Med. Phys. 28, 1364-1372 (2001).
-
(2001)
Med. Phys.
, vol.28
, pp. 1364-1372
-
-
Lachaine, M.1
Fourkal, E.2
Fallone, B.G.3
-
22
-
-
0031790998
-
Optimization of the scintillation detector in a combined 3D megavoltage CT scanner and portal imager
-
M. A. Mosleh-Shirazi, W. Swindell, and P. M. Evans, "Optimization of the scintillation detector in a combined 3D megavoltage CT scanner and portal imager," Med. Phys. 25, 1880-1890 (1998).
-
(1998)
Med. Phys.
, vol.25
, pp. 1880-1890
-
-
Mosleh-Shirazi, M.A.1
Swindell, W.2
Evans, P.M.3
-
23
-
-
0035989979
-
Theoretical analysis and experimental evaluation of a CsI(Tl) based electronic portal imaging system
-
A. Sawant, H. Zeman, S. Samant, G. Lovhoiden, B. Weinberg, and F. DiBianca, "Theoretical analysis and experimental evaluation of a CsI(Tl) based electronic portal imaging system," Med. Phys. 29, 1042-1053 (2002).
-
(2002)
Med. Phys.
, vol.29
, pp. 1042-1053
-
-
Sawant, A.1
Zeman, H.2
Samant, S.3
Lovhoiden, G.4
Weinberg, B.5
Dibianca, F.6
-
24
-
-
2442691615
-
Modeling scintillator-photodiodes as detectors for megavoltage CT
-
T. T. Monajemi, S. Steciw, B. G. Fallone, and S. Rathee, "Modeling scintillator-photodiodes as detectors for megavoltage CT," Med. Phys. 31, 1225-1234 (2004).
-
(2004)
Med. Phys.
, vol.31
, pp. 1225-1234
-
-
Monajemi, T.T.1
Steciw, S.2
Fallone, B.G.3
Rathee, S.4
-
25
-
-
27244438336
-
Segmented crystalline scintillators: An initial investigation of high quantum efficiency detectors for megavoltage x-ray imaging
-
A. Sawant, L. E. Antonuk, Y. El-Mohri, Q. Zhao, Y. Li, Z. Su, Y. Wang, J. Yamamoto, H. Du, I. Cunningham, M. Klugerman, and K. Shah, "Segmented crystalline scintillators: An initial investigation of high quantum efficiency detectors for megavoltage x-ray imaging," Med. Phys. 32, 3067-3083 (2005).
-
(2005)
Med. Phys.
, vol.32
, pp. 3067-3083
-
-
Sawant, A.1
Antonuk, L.E.2
El-Mohri, Y.3
Zhao, Q.4
Li, Y.5
Su, Z.6
Wang, Y.7
Yamamoto, J.8
Du, H.9
Cunningham, I.10
Klugerman, M.11
Shah, K.12
-
26
-
-
0001439538
-
Design of grid ionization chambers
-
O. Buneman, T. E. Cranshaw, and J. A. Harvey, "Design of grid ionization chambers," Can. J. Res., Sect. A 27, 191-206 (1949).
-
(1949)
Can. J. Res., Sect. A
, vol.27
, pp. 191-206
-
-
Buneman, O.1
Cranshaw, T.E.2
Harvey, J.A.3
-
27
-
-
0021800515
-
Kinestatic charge detection
-
F. A. DiBianca and M. B. Barker, "Kinestatic charge detection," Med. Phys. 12, 339-343 (1985).
-
(1985)
Med. Phys.
, vol.12
, pp. 339-343
-
-
DiBianca, F.A.1
Barker, M.B.2
-
28
-
-
0025877877
-
Use of a low-ionization dopant in a kinestatic charge detector: Experimental findings
-
D. J. Wagenaar, F. A. DiBianca, C. R. Tenney, M. S. C. Reed, and J. E. Vance, "Use of a low-ionization dopant in a kinestatic charge detector: Experimental findings," Med. Phys. 18, 227-235 (1991).
-
(1991)
Med. Phys.
, vol.18
, pp. 227-235
-
-
Wagenaar, D.J.1
DiBianca, F.A.2
Tenney, C.R.3
Reed, M.S.C.4
Vance, J.E.5
-
29
-
-
33748287244
-
-
M.S. thesis, University of Tennessee, Memphis, TN
-
S. Devidas, "Electron attachment and gas optimization studies in a KCD for digital radiography," M.S. thesis, University of Tennessee, Memphis, TN, 1994.
-
(1994)
Electron Attachment and Gas Optimization Studies in a KCD for Digital Radiography
-
-
Devidas, S.1
-
30
-
-
0018575636
-
Transfer function analysis of radiographic imaging systems
-
C. E. Metz and K. Doi, "Transfer function analysis of radiographic imaging systems," Phys. Med. Biol. 24, 1079-1106 (1979).
-
(1979)
Phys. Med. Biol.
, vol.24
, pp. 1079-1106
-
-
Metz, C.E.1
Doi, K.2
-
31
-
-
0000188292
-
The specification of imaging properties by response to a sine wave input
-
J. W. Coltman, "The specification of imaging properties by response to a sine wave input," J. Opt. Soc. Am. 44, 468-471 (1954).
-
(1954)
J. Opt. Soc. Am.
, vol.44
, pp. 468-471
-
-
Coltman, J.W.1
-
32
-
-
0022337957
-
An MTF method immune to aliasing
-
R. T. Droege and M. S. Rzeszotarski, "An MTF method immune to aliasing," Med. Phys. 12, 721-725 (1985).
-
(1985)
Med. Phys.
, vol.12
, pp. 721-725
-
-
Droege, R.T.1
Rzeszotarski, M.S.2
-
34
-
-
0032767557
-
Noise power spectra of images from digital mammography detectors
-
M. B. Williams, "Noise power spectra of images from digital mammography detectors," Med. Phys. 26, 1279-1293 (1999).
-
(1999)
Med. Phys.
, vol.26
, pp. 1279-1293
-
-
Williams, M.B.1
-
35
-
-
33744708254
-
General recombination in ionization chambers with spatially non-uniform ionization intensity - Two special cases
-
J. W. Boag, "General recombination in ionization chambers with spatially non-uniform ionization intensity - Two special cases," Int. J. Radiat. Phys. Chem. 7, 243 (1975).
-
(1975)
Int. J. Radiat. Phys. Chem.
, vol.7
, pp. 243
-
-
Boag, J.W.1
-
38
-
-
0026837927
-
A simple method for determining the modulation transfer function in digital radiography
-
H. Fujita, D. Tsai, T. Itoh, K. Doi, J. Morishita, K. Ueda, and A. Ohtsuka, "A simple method for determining the modulation transfer function in digital radiography," IEEE Trans. Med. Imaging 11, 34-39 (1992).
-
(1992)
IEEE Trans. Med. Imaging
, vol.11
, pp. 34-39
-
-
Fujita, H.1
Tsai, D.2
Itoh, T.3
Doi, K.4
Morishita, J.5
Ueda, K.6
Ohtsuka, A.7
-
39
-
-
0027752810
-
X-ray sources of medical linear accelerators: Focal and extra-focal radiation
-
D. A. Jaffray, J. J. Battista, A. Fenster, and P. Munro, "X-ray sources of medical linear accelerators: Focal and extra-focal radiation," Med. Phys. 20, 1417-1427 (1993).
-
(1993)
Med. Phys.
, vol.20
, pp. 1417-1427
-
-
Jaffray, D.A.1
Battista, J.J.2
Fenster, A.3
Munro, P.4
-
40
-
-
0028840692
-
DQE(f) of four generations of computed radiography acquisition devices
-
J. T. Dobbins, D. L. Ergun, L. Rutz, D. A. Hinshaw, H. Blume, and D. C. Clark, "DQE(f) of four generations of computed radiography acquisition devices," Med. Phys. 22, 1581-1593 (1995).
-
(1995)
Med. Phys.
, vol.22
, pp. 1581-1593
-
-
Dobbins, J.T.1
Ergun, D.L.2
Rutz, L.3
Hinshaw, D.A.4
Blume, H.5
Clark, D.C.6
-
41
-
-
0021264167
-
Fluence to dose equivalent conversion factors calculated with egs for electrons from 100 Kev to 20 Gev and photons from 11 Kev to 20 Gev
-
D. W. O. Rogers, "Fluence to dose equivalent conversion factors calculated with egs for electrons from 100 Kev to 20 Gev and photons from 11 Kev to 20 Gev," Health Phys. 46, 891-914 (1984).
-
(1984)
Health Phys.
, vol.46
, pp. 891-914
-
-
Rogers, D.W.O.1
-
42
-
-
0027933089
-
Optimal radiographic magnification for portal imaging
-
J. P. Bisonnette, D. A. Jaffray, A. Fenster, and P. Munro, "Optimal radiographic magnification for portal imaging," Med. Phys. 21, 1435-1445 (1994).
-
(1994)
Med. Phys.
, vol.21
, pp. 1435-1445
-
-
Bisonnette, J.P.1
Jaffray, D.A.2
Fenster, A.3
Munro, P.4
-
43
-
-
0031860585
-
X-Ray quantum limited portal imaging using amorphous silicon flat-panel arrays
-
P. Munro and D. C. Bouius, "X-Ray quantum limited portal imaging using amorphous silicon flat-panel arrays," Med. Phys. 25, 689-702 (1998).
-
(1998)
Med. Phys.
, vol.25
, pp. 689-702
-
-
Munro, P.1
Bouius, D.C.2
-
44
-
-
0004297165
-
-
SANDIA91-1634 Sandia National Laboratories, Albuquerque, NM
-
J. A. Halbleib, R. P. Kensek, T. A. Mehlhorn, G. D. Valdez, S. M. Seltzer, and M. J. Berger, "ITS Version 3.0: Integrated tiger series for coupled photon/electron," SANDIA91-1634 (Sandia National Laboratories, Albuquerque, NM, 1992).
-
(1992)
ITS Version 3.0: Integrated Tiger Series for Coupled Photon/electron
-
-
Halbleib, J.A.1
Kensek, R.P.2
Mehlhorn, T.A.3
Valdez, G.D.4
Seltzer, S.M.5
Berger, M.J.6
-
45
-
-
0021849353
-
Energy and angular distribution of photons from medical linear accelerators
-
R. Mohan, C. Chui, and L. Lidofsky, "Energy and angular distribution of photons from medical linear accelerators," Med. Phys. 12, 592-597 (1985).
-
(1985)
Med. Phys.
, vol.12
, pp. 592-597
-
-
Mohan, R.1
Chui, C.2
Lidofsky, L.3
-
46
-
-
0003797114
-
The EGSnrc code system: Monte Carlo simulation of electron and photon transport
-
I. Kawrakow and D. W. O. Rogers, "The EGSnrc code system: Monte Carlo simulation of electron and photon transport," NRCC Report No. PIRS-701 (2000).
-
(2000)
NRCC Report No. PIRS-701
-
-
Kawrakow, I.1
Rogers, D.W.O.2
-
47
-
-
0024990547
-
Monte Carlo and convolution dosimetry for stereotactic radiosurgery
-
S. S. Kusbad, T. R. Mackie, M. A. Gehring, D. J. Misisco, B. R. Paliwal, M. P. Mehta, and T. J. Kinsella, "Monte Carlo and convolution dosimetry for stereotactic radiosurgery," Int. J. Radiat. Oncol., Biol., Phys. 19, 1027-1035 (1990).
-
(1990)
Int. J. Radiat. Oncol., Biol., Phys.
, vol.19
, pp. 1027-1035
-
-
Kusbad, S.S.1
Mackie, T.R.2
Gehring, M.A.3
Misisco, D.J.4
Paliwal, B.R.5
Mehta, M.P.6
Kinsella, T.J.7
-
48
-
-
0032414194
-
Characteristics of metal-plate/film detectors at therapy energies. I. modulation transfer function
-
T. Falco and B. G. Fallone, "Characteristics of metal-plate/film detectors at therapy energies. I. modulation transfer function," Med. Phys. 25, 2455-2462 (1998).
-
(1998)
Med. Phys.
, vol.25
, pp. 2455-2462
-
-
Falco, T.1
Fallone, B.G.2
|