Volumn 47, Issue 2, 2000, Pages 202208-

Experimental and numerical determination of SAR distributions within culture flasks in a dielectric loaded radial transmission line

Author keywords

Culture flask; Dielectric loading; Finitedifference timedomain (FDTD) specific absorption rate (SAR) modeling; Frequencydomain SAR modeling; Heat diffusion; Nonuniform SAR; Radial transmission line (RTL); Transverse electromagnetic (TEM)

Indexed keywords


EID: 33748173753     PISSN: 00189294     EISSN: None     Source Type: Journal    
DOI: 10.1109/10.821756     Document Type: Article
Times cited : (29)

References (7)
  • 1
    • 0032618025 scopus 로고    scopus 로고
    • Simplified model and measurement of specific absorption rate distribution in a culture flask within a transverse electromagnetic mode exposure system
    • vol. 20, pp. 183193, 1999.
    • W. F. Pickard, W. E. Sträube, E. G. Moros, and X. Fan, "Simplified model and measurement of specific absorption rate distribution in a culture flask within a transverse electromagnetic mode exposure system," Bioelectromagnetics, vol. 20, pp. 183193, 1999.
    • Bioelectromagnetics
    • Pickard, W.F.1    Sträube, W.E.2    Moros, E.G.3    Fan, X.4
  • 2
    • 0030345862 scopus 로고    scopus 로고
    • Numerical and experimental dosimetry of Petri dish exposure setups
    • vol. 17, pp. 483493, 1996.
    • M. Burkhardt, K. Popovic, M. Gnos, T. Schmid, and N. Küster, "Numerical and experimental dosimetry of Petri dish exposure setups," Bioelectromagnetics, vol. 17, pp. 483493, 1996.
    • Bioelectromagnetics
    • Burkhardt, M.1    Popovic, K.2    Gnos, M.3    Schmid, T.4    Küster, N.5
  • 3
    • 31744432248 scopus 로고    scopus 로고
    • The starting point: Wireless Technology Reserch, L.L.C.'s dosimetry risk evaluation research
    • vol. 3, pp. 2550, 1997.
    • A. W. Guy, "The starting point: Wireless Technology Reserch, L.L.C.'s dosimetry risk evaluation research," Hum. Ecol. Risk. Assess, vol. 3, pp. 2550, 1997.
    • Hum. Ecol. Risk. Assess
    • Guy, A.W.1
  • 4
    • 0032146994 scopus 로고    scopus 로고
    • Finitedifference timedomain analysis of a complete transverse electromagnetic cellloaded with liquid biological media in culture dishes
    • vol. 45, pp. 10671076, Aug. 1998.
    • M. Popovic, S. C. Hagness, and A. Taflove, "Finitedifference timedomain analysis of a complete transverse electromagnetic cellloaded with liquid biological media in culture dishes," IEEE Trans. Biomed. Eng., vol. 45, pp. 10671076, Aug. 1998.
    • IEEE Trans. Biomed. Eng.
    • Popovic, M.1    Hagness, S.C.2    Taflove, A.3
  • 5
    • 0032617067 scopus 로고    scopus 로고
    • The radial transmission line as a broadband shielded exposure system for microwave irradiation of large numbers of culture flasks
    • vol. 20, pp. 6580, 1999.
    • E. G. Moros, W. L. Sträube, and W. F. Pickard, "The radial transmission line as a broadband shielded exposure system for microwave irradiation of large numbers of culture flasks," Bioetectromagnetics, vol. 20, pp. 6580, 1999.
    • Bioetectromagnetics
    • Moros, E.G.1    Sträube, W.L.2    Pickard, W.F.3
  • 6
    • 33748186944 scopus 로고    scopus 로고
    • Track structure considerations in low dose and low dose rate effects of ionizing radiation
    • vol. 16, pp. 744, 1992.
    • D. T. Goodhead, "Track structure considerations in low dose and low dose rate effects of ionizing radiation," Adv. Rad. Res, vol. 16, pp. 744, 1992.
    • Adv. Rad. Res
    • Goodhead, D.T.1
  • 7
    • 0032865573 scopus 로고    scopus 로고
    • On the assumption of negligible heat diffusion during the thermal measurement of a nonuniform specific absorption rate
    • vol. 152, pp. 312320, 1999.
    • E. G. Moros and W. F. Pickard, "On the assumption of negligible heat diffusion during the thermal measurement of a nonuniform specific absorption rate," Rad. Res, vol. 152, pp. 312320, 1999.
    • Rad. Res