메뉴 건너뛰기




Volumn 51, Issue 2, 2006, Pages 140-144

Force-dependent static dead space of face masks used with holding chambers

Author keywords

Aerosol; Child; Dead space; Drug delivery; Masks; Metered dose inhaler; pMDI; Valved holding chamber

Indexed keywords

ANALYSIS OF VARIANCE; ARTICLE; DRUG DELIVERY SYSTEM; FACE MASK; LUNG CAPACITY; STATISTICAL SIGNIFICANCE; AEROSOL; COMPARATIVE STUDY; EQUIPMENT DESIGN; FACE; FEMALE; HUMAN; INHALATION SPACER; INHALATIONAL DRUG ADMINISTRATION; MALE; MASK; METERED DOSE INHALER; PRESCHOOL CHILD; STANDARD;

EID: 33748155376     PISSN: 00201324     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (50)

References (11)
  • 1
    • 3342936801 scopus 로고    scopus 로고
    • β-agonists through metered-dose inhaler with valved holding chamber versus nebulizer for acute exacerbation of wheezing or asthma in children under 5 years of age: A systematic review with meta-analysis
    • Castro-Rodriguez JA, Rodrigo GJ. β-agonists through metered-dose inhaler with valved holding chamber versus nebulizer for acute exacerbation of wheezing or asthma in children under 5 years of age: a systematic review with meta-analysis. J Pediatr 2004;145(2):172-177.
    • (2004) J Pediatr , vol.145 , Issue.2 , pp. 172-177
    • Castro-Rodriguez, J.A.1    Rodrigo, G.J.2
  • 2
    • 0026577289 scopus 로고
    • Drug delivery from holding chambers with attached face mask
    • Everard ML, Clark AR, Milner AD. Drug delivery from holding chambers with attached face mask. Arch Dis Child 1992;67(5):580-585.
    • (1992) Arch Dis Child , vol.67 , Issue.5 , pp. 580-585
    • Everard, M.L.1    Clark, A.R.2    Milner, A.D.3
  • 3
    • 34250003165 scopus 로고    scopus 로고
    • Mitchell JP, Nagel MW, Dolovich MB. Delivery of beclomethasone dipropionate (BDP) as a function of number of breaths at low tidal in two small holding chambers for pediatric use. Eur Respir J 1996;9S23:433.
    • Mitchell JP, Nagel MW, Dolovich MB. Delivery of beclomethasone dipropionate (BDP) as a function of number of breaths at low tidal volume in two small volume holding chambers for pediatric use. Eur Respir J 1996;9S23:433.
  • 5
    • 0034889461 scopus 로고    scopus 로고
    • Aerosol therapy with valved holding chambers in young children: Importance of the face mask seal
    • Amirav I, Newhouse MT. Aerosol therapy with valved holding chambers in young children: importance of the face mask seal. Pediatrics 2001;108(2):389-394.
    • (2001) Pediatrics , vol.108 , Issue.2 , pp. 389-394
    • Amirav, I.1    Newhouse, M.T.2
  • 9
    • 0032777733 scopus 로고    scopus 로고
    • Crying significantly reduces absorption of aerosolised drug in infants
    • Iles R, Lister P, Edmunds AT. Crying significantly reduces absorption of aerosolised drug in infants. Arch Dis Child 1999;81(2):163-165.
    • (1999) Arch Dis Child , vol.81 , Issue.2 , pp. 163-165
    • Iles, R.1    Lister, P.2    Edmunds, A.T.3
  • 11
    • 0346607207 scopus 로고    scopus 로고
    • Dynamic dead space in face masks used with noninvasive ventilators: A lung model study
    • Saatci E, Miller DM, Stelli IM, Lee KC, Moxham J. Dynamic dead space in face masks used with noninvasive ventilators: a lung model study. Eur Respir J 2004;23(1):129-135.
    • (2004) Eur Respir J , vol.23 , Issue.1 , pp. 129-135
    • Saatci, E.1    Miller, D.M.2    Stelli, I.M.3    Lee, K.C.4    Moxham, J.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.