메뉴 건너뛰기




Volumn 40, Issue 2, 2006, Pages 149-155

Clamp before you cut: Proximal control of ruptured abdominal aortic aneurysms using endovascular balloon occlusion - Case reports

Author keywords

[No Author keywords available]

Indexed keywords

ABDOMINAL AORTA ANEURYSM; AGED; ANEURYSM RUPTURE; AORTA CLAMPING; AORTA GRAFT; ARTICLE; BALLOON OCCLUSION; CASE REPORT; COMORBIDITY; ENDOVASCULAR SURGERY; HEMODYNAMICS; HUMAN; MALE; MORBIDITY; STENT; SURGICAL MORTALITY; SURGICAL TECHNIQUE; ALGORITHM; AORTA RUPTURE; HEMOSTASIS; INSTRUMENTATION; METHODOLOGY; MIDDLE AGED; PERCUTANEOUS TRANSLUMINAL ANGIOPLASTY; PRACTICE GUIDELINE; PREOPERATIVE CARE; RUPTURE; TREATMENT OUTCOME; VASCULAR SURGERY;

EID: 33747839193     PISSN: 15385744     EISSN: None     Source Type: Journal    
DOI: 10.1177/153857440604000210     Document Type: Article
Times cited : (33)

References (19)
  • 1
    • 0002895138 scopus 로고
    • Use of an intra-aortic balloon catheter tamponade for controlling intra-abdominal hemorrhage in man
    • Hughes CW: Use of an intra-aortic balloon catheter tamponade for controlling intra-abdominal hemorrhage in man. Surgery 36:65-68, 1954.
    • (1954) Surgery , vol.36 , pp. 65-68
    • Hughes, C.W.1
  • 2
    • 0036274867 scopus 로고    scopus 로고
    • A meta-analysis of 50 years of ruptured abdominal aortic aneurysm repair
    • Bown MJ, Sutton AJ, Bell PR, et al: A meta-analysis of 50 years of ruptured abdominal aortic aneurysm repair. Br J Surg 89:714-730, 2002.
    • (2002) Br J Surg , vol.89 , pp. 714-730
    • Bown, M.J.1    Sutton, A.J.2    Bell, P.R.3
  • 3
    • 0032885844 scopus 로고    scopus 로고
    • Mortality rates following endovascular repair of abdominal aortic aneurysms
    • Walker S, Macierewicz J, MacSweeney S: Mortality rates following endovascular repair of abdominal aortic aneurysms. J Endovasc Surg 6:233-238, 1999.
    • (1999) J Endovasc Surg , vol.6 , pp. 233-238
    • Walker, S.1    Macierewicz, J.2    MacSweeney, S.3
  • 4
    • 0037938539 scopus 로고    scopus 로고
    • Treatment of ruptured abdominal aneurysms with stent grafts: A new gold standard?
    • Veith FJ, Lipsitz EC, Suggs WD, et al: Treatment of ruptured abdominal aneurysms with stent grafts: A new gold standard? Semin Vasc Surg 16:171-175, 2003.
    • (2003) Semin Vasc Surg , vol.16 , pp. 171-175
    • Veith, F.J.1    Lipsitz, E.C.2    Suggs, W.D.3
  • 5
    • 1642464831 scopus 로고    scopus 로고
    • Feasibility of preoperative computer tomography in patients with ruptured abdominal aortic aneurysm: A time-to-death study in patients without operation
    • Lloyd GM, Bown MJ: Feasibility of preoperative computer tomography in patients with ruptured abdominal aortic aneurysm: A time-to-death study in patients without operation. J Vasc Surg 39:788-791, 2004.
    • (2004) J Vasc Surg , vol.39 , pp. 788-791
    • Lloyd, G.M.1    Bown, M.J.2
  • 6
    • 33748954581 scopus 로고
    • Notes on the arrest of hepatic hemorrhage due to trauma
    • Pringle JH: Notes on the arrest of hepatic hemorrhage due to trauma. Ann Surg 163:257-259, 1966.
    • (1966) Ann Surg , vol.163 , pp. 257-259
    • Pringle, J.H.1
  • 7
    • 0024360581 scopus 로고
    • Ruptured abdominal aneurysms: Special considerations
    • Rutherford RB, McCroskey BL: Ruptured abdominal aneurysms: Special considerations. Surg Clin North Am 69:868-869, 1989.
    • (1989) Surg Clin North Am , vol.69 , pp. 868-869
    • Rutherford, R.B.1    McCroskey, B.L.2
  • 8
    • 0001684927 scopus 로고
    • Rupture of abdominal aortic aneurysm: Control of hemorrhage by intraluminal balloon tamponade
    • Hesse FG, Kletschka HD: Rupture of abdominal aortic aneurysm: Control of hemorrhage by intraluminal balloon tamponade. Ann Surg 155:320-322, 1962.
    • (1962) Ann Surg , vol.155 , pp. 320-322
    • Hesse, F.G.1    Kletschka, H.D.2
  • 9
    • 0015097216 scopus 로고
    • New technique for control of ruptured abdominal aortic aneurysm
    • Berkowitz HD, Roberts B: New technique for control of ruptured abdominal aortic aneurysm. Surg Gynecol Obstet 133:107-109, 1971.
    • (1971) Surg Gynecol Obstet , vol.133 , pp. 107-109
    • Berkowitz, H.D.1    Roberts, B.2
  • 10
    • 0014884344 scopus 로고
    • The elective use of balloon obstruction in aortic surgery
    • Robicesek F, Daugherty HK, Mullen DC: The elective use of balloon obstruction in aortic surgery. Surgery 68:774-777, 1970.
    • (1970) Surgery , vol.68 , pp. 774-777
    • Robicesek, F.1    Daugherty, H.K.2    Mullen, D.C.3
  • 11
  • 12
    • 0345167818 scopus 로고    scopus 로고
    • Transbrachial arterial insertion of aortic occlusion balloon catheter in patients with shock from ruptured abdominal aneurysm
    • Matsuda H, Tanaka Y, Hino Y, et al: Transbrachial arterial insertion of aortic occlusion balloon catheter in patients with shock from ruptured abdominal aneurysm. J Vasc Surg 38:1293-1296, 2003.
    • (2003) J Vasc Surg , vol.38 , pp. 1293-1296
    • Matsuda, H.1    Tanaka, Y.2    Hino, Y.3
  • 13
    • 0034768795 scopus 로고    scopus 로고
    • Successful surgical treatment of a ruptured abdominal aortic aneurysm without homologous blood transfusion in a Jehovah's Witness: Report of case
    • Namura O, Kanazawa K, Yoshiya K, et al: Successful surgical treatment of a ruptured abdominal aortic aneurysm without homologous blood transfusion in a Jehovah's Witness: Report of case. Surg Today 31:912-914, 2001.
    • (2001) Surg Today , vol.31 , pp. 912-914
    • Namura, O.1    Kanazawa, K.2    Yoshiya, K.3
  • 14
    • 0033819746 scopus 로고    scopus 로고
    • Endvoascular grafts and other image-guided catheter-based adjuncts to improve the treatment of ruptured aortoiliac aneurysms
    • Ohki T, Veith FJ: Endvoascular grafts and other image-guided catheter-based adjuncts to improve the treatment of ruptured aortoiliac aneurysms. Ann Surg 232:466-479, 2000.
    • (2000) Ann Surg , vol.232 , pp. 466-479
    • Ohki, T.1    Veith, F.J.2
  • 15
    • 0022536157 scopus 로고
    • Transaxillary intra-aortic balloon tamponade in trauma
    • Wolf RK, Berry RE: Transaxillary intra-aortic balloon tamponade in trauma. J Vasc Surg 4:95-97, 1986.
    • (1986) J Vasc Surg , vol.4 , pp. 95-97
    • Wolf, R.K.1    Berry, R.E.2
  • 16
    • 0024366558 scopus 로고
    • The role of intra-aortic balloon occlusion in penetrating abdominal trauma
    • Gupta BK, Khaneja SC, Flores L, et al: The role of intra-aortic balloon occlusion in penetrating abdominal trauma. J Trauma 29:861-865, 1989.
    • (1989) J Trauma , vol.29 , pp. 861-865
    • Gupta, B.K.1    Khaneja, S.C.2    Flores, L.3
  • 17
    • 0345167818 scopus 로고    scopus 로고
    • Transbrachial arterial insertion of aortic occlusion balloon catheter in patients with shock from ruptured abdominal aneurysm
    • Matsuda H, Tanaka Y, Hino Y, et al: Transbrachial arterial insertion of aortic occlusion balloon catheter in patients with shock from ruptured abdominal aneurysm. J Vasc Surg 38:1293-1299, 2003.
    • (2003) J Vasc Surg , vol.38 , pp. 1293-1299
    • Matsuda, H.1    Tanaka, Y.2    Hino, Y.3
  • 18
    • 0022970153 scopus 로고
    • Preliminary report of the use of the Percluder occluding aortic balloon in human beings
    • Low RB, Longmore W, Rubinstein R, et al: Preliminary report of the use of the Percluder occluding aortic balloon in human beings. Ann Emerg Med 15:1466-1469, 1986.
    • (1986) Ann Emerg Med , vol.15 , pp. 1466-1469
    • Low, R.B.1    Longmore, W.2    Rubinstein, R.3
  • 19
    • 0017866946 scopus 로고
    • Intermittent occlusion of the abdominal aorta: A conceptual approach to treating below diaphragm tumors
    • Pascal O, Wajsman Z, Jennings EC: Intermittent occlusion of the abdominal aorta: A conceptual approach to treating below diaphragm tumors. J Surg Oncol 10:225-237, 1978.
    • (1978) J Surg Oncol , vol.10 , pp. 225-237
    • Pascal, O.1    Wajsman, Z.2    Jennings, E.C.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.