메뉴 건너뛰기




Volumn 38, Issue 6, 2003, Pages 1293-1296

Transbrachial arterial insertion of aortic occlusion balloon catheter in patients with shock from ruptured abdominal aortic aneurysm

Author keywords

[No Author keywords available]

Indexed keywords

ABDOMINAL AORTA; ABDOMINAL AORTA ANEURYSM; ADULT; AGED; ANEURYSM RUPTURE; AORTA OCCLUSION; ARTICLE; BALLOON CATHETER; BRACHIAL ARTERY; CATHETERIZATION; FEMALE; HEMORRHAGIC SHOCK; HUMAN; LAPAROTOMY; LOCAL ANESTHESIA; MAJOR CLINICAL STUDY; MALE; PRIORITY JOURNAL; SUBCLAVIAN ARTERY; SURGICAL MORTALITY; SYSTOLIC BLOOD PRESSURE; THORACIC AORTA;

EID: 0345167818     PISSN: 07415214     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0741-5214(03)00774-2     Document Type: Article
Times cited : (46)

References (25)
  • 3
    • 0031694386 scopus 로고    scopus 로고
    • Surgical repair of ruptured abdominal aortic aneurysms in the state of Maryland: Factors influencing outcome among 527 recent cases
    • Dardik A, Burleyson GP, Bowman H, Gordon TA, Williams GM, Webb TH, et al. Surgical repair of ruptured abdominal aortic aneurysms in the state of Maryland: factors influencing outcome among 527 recent cases. J Vasc Surg 1998;28:413-20.
    • (1998) J Vasc Surg , vol.28 , pp. 413-420
    • Dardik, A.1    Burleyson, G.P.2    Bowman, H.3    Gordon, T.A.4    Williams, G.M.5    Webb, T.H.6
  • 5
    • 0034144594 scopus 로고    scopus 로고
    • Ruptured abdominal aortic aneurysm: A novel method of outcome prediction using neural network technology
    • Turton EP, Scott DJ, Delbridge M, Snowden S, Kcstcr RC. Ruptured abdominal aortic aneurysm: a novel method of outcome prediction using neural network technology. Eur J Vasc Endovasc Surg 2000;19:184-9.
    • (2000) Eur J Vasc Endovasc Surg , vol.19 , pp. 184-189
    • Turton, E.P.1    Scott, D.J.2    Delbridge, M.3    Snowden, S.4    Kcstcr, R.C.5
  • 6
    • 0022655487 scopus 로고
    • Ruptured abdominal aortic aneurysms: A study of incidence and mortality
    • Johansson G, Swedenborg J. Ruptured abdominal aortic aneurysms: a study of incidence and mortality. Br J Surg 1986;73:101-3.
    • (1986) Br J Surg , vol.73 , pp. 101-103
    • Johansson, G.1    Swedenborg, J.2
  • 7
    • 0028285089 scopus 로고
    • Operative mortality rates for intact and ruptured abdominal aortic aneurysms in Michigan: An eleven-year statewide experience
    • Katz DJ, Stanley JC, Zelenock GB. Operative mortality rates for intact and ruptured abdominal aortic aneurysms in Michigan: an eleven-year statewide experience. J Vasc Surg 1994;19:804-17.
    • (1994) J Vasc Surg , vol.19 , pp. 804-817
    • Katz, D.J.1    Stanley, J.C.2    Zelenock, G.B.3
  • 9
    • 0022415670 scopus 로고
    • Factors affecting survival after ruptured abdominal aortic aneurysm
    • Donaldson MC, Rosenberg JM, Bucknam CA. Factors affecting survival after ruptured abdominal aortic aneurysm. J Vasc Surg 1985;2:564-70.
    • (1985) J Vasc Surg , vol.2 , pp. 564-570
    • Donaldson, M.C.1    Rosenberg, J.M.2    Bucknam, C.A.3
  • 10
    • 0037708809 scopus 로고
    • Ruptured abdominal aortic Aneurysms
    • Rutherford RB, ed. Philadelphia, Pa: Saunders
    • Gloviczki P. Ruptured abdominal aortic Aneurysms. In: Rutherford RB, ed. Vascular surgery. Philadelphia, Pa: Saunders, 1995:p 1060-9.
    • (1995) Vascular Surgery , pp. 1060-1069
    • Gloviczki, P.1
  • 11
    • 0024360581 scopus 로고
    • Ruptured abdominal aortic aneurysms: Special considerations
    • Rutherford RB, McCroskey BL. Ruptured abdominal aortic aneurysms: special considerations. Surg Clin North Am 1989;69:859-68.
    • (1989) Surg Clin North Am , vol.69 , pp. 859-868
    • Rutherford, R.B.1    McCroskey, B.L.2
  • 12
    • 0345563896 scopus 로고
    • An aortic tampon for emergency control of ruptured abdominal aneurysm
    • Heimbecker RO. An aortic tampon for emergency control of ruptured abdominal aneurysm. Can Med Assoc J 1964;91:1024-5.
    • (1964) Can Med Assoc J , vol.91 , pp. 1024-1025
    • Heimbecker, R.O.1
  • 13
    • 0015305185 scopus 로고
    • Emergency control of ruptured abdominal aortic aneurysm by transaxillary balloon catheter
    • Smith FG. Emergency control of ruptured abdominal aortic aneurysm by transaxillary balloon catheter. Vasc Surg 1972;6:79-84.
    • (1972) Vasc Surg , vol.6 , pp. 79-84
    • Smith, F.G.1
  • 14
    • 0019513826 scopus 로고
    • Rapid control in ruptured abdominal aneurysms
    • Sensenig DM. Rapid control in ruptured abdominal aneurysms. Arch Surg 1981;116:1034-6.
    • (1981) Arch Surg , vol.116 , pp. 1034-1036
    • Sensenig, D.M.1
  • 15
    • 0017805344 scopus 로고
    • Balloon catheter control of a ruptured abdominal aortic aneurysm in a patient with Cullen's sign
    • Armour RH, Clifton MA, Marsh CH. Balloon catheter control of a ruptured abdominal aortic aneurysm in a patient with Cullen's sign. Br J Surg 1978;65:350.
    • (1978) Br J Surg , vol.65 , pp. 350
    • Armour, R.H.1    Clifton, M.A.2    Marsh, C.H.3
  • 16
    • 0031915265 scopus 로고    scopus 로고
    • Graft reconstruction using an intraluminal balloon catheter in ruptured abdominal aortic aneurysms
    • Lorenzi M, Mancini S, Mancini S. Graft reconstruction using an intraluminal balloon catheter in ruptured abdominal aortic aneurysms. Eur J Surg 1998;164:147-8.
    • (1998) Eur J Surg , vol.164 , pp. 147-148
    • Lorenzi, M.1    Mancini, S.2    Mancini, S.3
  • 17
    • 0021030068 scopus 로고
    • The double balloon cannula in the treatment of ruptured abdominal aneurysms
    • Hoshino S, Igari T, Iwaya F, Honda K. The double balloon cannula in the treatment of ruptured abdominal aneurysms. Int Surg 1983;68:219-21.
    • (1983) Int Surg , vol.68 , pp. 219-221
    • Hoshino, S.1    Igari, T.2    Iwaya, F.3    Honda, K.4
  • 19
    • 0345132407 scopus 로고
    • Utility of balloon occlusion catheter for ruptured abdominal aortic aneurysm
    • Morohoshi Y, et al. Utility of balloon occlusion catheter for ruptured abdominal aortic aneurysm. Jpn J Cardiovasc Surg 1992;21:383-7.
    • (1992) Jpn J Cardiovasc Surg , vol.21 , pp. 383-387
    • Morohoshi, Y.1
  • 20
    • 0017360237 scopus 로고
    • Use of Fogarty catheter tamponade for ruptured abdominal aortic aneurysms
    • Ng AC, Ochsner EC. Use of Fogarty catheter tamponade for ruptured abdominal aortic aneurysms. AJR 1977;128:31-3.
    • (1977) AJR , vol.128 , pp. 31-33
    • Ng, A.C.1    Ochsner, E.C.2
  • 21
    • 0033819746 scopus 로고    scopus 로고
    • Endovascular grafts and other image-guided catheter-based adjuncts to improve the treatment of ruptured aortoiliac aneurysms
    • Ohki T, Veith FJ. Endovascular grafts and other image-guided catheter-based adjuncts to improve the treatment of ruptured aortoiliac aneurysms. Ann Surg 2000;232:466-79.
    • (2000) Ann Surg , vol.232 , pp. 466-479
    • Ohki, T.1    Veith, F.J.2
  • 22
    • 0345132408 scopus 로고
    • Emergency aortic reconstruction
    • Bergan JJ, Yao JST, eds. Philadelphia, Pa: Saunders
    • Ernst CB. Emergency aortic reconstruction. In: Bergan JJ, Yao JST, eds. Techniques in arterial surgery. Philadelphia, Pa: Saunders, 1990:42-55.
    • (1990) Techniques in Arterial Surgery , pp. 42-55
    • Ernst, C.B.1
  • 23
    • 0001345012 scopus 로고
    • Intraluminal aortic occlusion as a possible mechanism for controlling massive intra-abdominal hemorrhage
    • Edwards WS, Salter PP Jr. Intraluminal aortic occlusion as a possible mechanism for controlling massive intra-abdominal hemorrhage. Surg Forum 1953;4:496-9.
    • (1953) Surg Forum , vol.4 , pp. 496-499
    • Edwards, W.S.1    Salter Jr., P.P.2
  • 25
    • 0345563895 scopus 로고    scopus 로고
    • Cerebral embolism following attempted balloon occlusion of a ruptured abdominal aortic aneurysm
    • Tahata T, Miki S, Ueda Y, Ogino H, Morioka K, Sakai T, et al. Cerebral embolism following attempted balloon occlusion of a ruptured abdominal aortic aneurysm. Jpn J Cardiovasc Surg 1996;25:337-9.
    • (1996) Jpn J Cardiovasc Surg , vol.25 , pp. 337-339
    • Tahata, T.1    Miki, S.2    Ueda, Y.3    Ogino, H.4    Morioka, K.5    Sakai, T.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.